NEC Neax 2400 Imx Direct Station Selection Console Manual
Have a look at the manual NEC Neax 2400 Imx Direct Station Selection Console Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

AUGUST, 1999 NEC America, Inc. ND-70684 (E) ISSUE 1 STOCK # 200863 Direct Station Selection (DSS) Console System Manual ®

LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. NEAX and D term are registered trademarks of NEC Corporation. Copyright 1999 NEC America, Inc. Printed in the U.S.A

ND-70684 (E) ISSUE 1 AUGUST, 1999 NEAX2400 IMX Direct Station Selection (DSS) Console System Manual TABLE OF CONTENTS Page ND-70684 (E) TABLE OF CONTENTS Page i Revision 1.0 CHAPTER 1 OVERVIEW .................................................................................................................................. 1 1. General .................................................................................................................................................... 1 2. How to Follow This Manual ...................................................................................................................... 2 3. DSS Console Modes................................................................................................................................ 3 3.1 Direct Station Selection/Busy Lamp Field (DSS/BLF ) Mode ..................................................... 3 3.2 Add-On Module (ADM) Mode ..................................................................................................... 4 4. DSS Specifications .................................................................................................................................. 5 5. General Service Conditions ..................................................................................................................... 6 6. DSS/BLF .................................................................................................................................................. 7 7. Add-On Module ...................................................................................................................................... 10 CHAPTER 2 INSTALLATION PROCEDURE .................................................................................................. 15 1. Connection Diagram for DSS/BLF ......................................................................................................... 15 2. Connection Diagram for the Add-On Module ......................................................................................... 16 3. Cable Lead Location .............................................................................................................................. 17 CHAPTER 3 DATA PROGRAMMING ............................................................................................................. 19 1. DSS/BLF ................................................................................................................................................ 19 2. Data Programming Procedure (DSS/BLF) ............................................................................................. 20 2.1 Example of Data Programming for DSS/BLF ............................................................................ 23 2.1.1 ASDT ........................................................................................................................... 23 2.1.2 AKYD ........................................................................................................................... 24 3. Add-On Module ...................................................................................................................................... 28 4. Data Programming Procedure for Add-On Module ................................................................................ 29 4.1 Example of Data Programming for Add-On Module.................................................................. 32 4.1.1 ASDT ........................................................................................................................... 32 4.1.2 AKYD ........................................................................................................................... 32 5. Office Data Setting Sheets..................................................................................................................... 37 5.1 ASDT ........................................................................................................................................ 37 5.2 AKYD ........................................................................................................................................ 38

TABLE OF CONTENTS ND-70684 (E) Page ii Revision 1.0 This page is for your notes.

LIST OF FIGURES Figure TitlePag e ND-70684 (E) LIST OF FIGURES Page iii Revision 1.0 Figure 1-1 Outer View of DSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 1-2 Direct Station Selection (DSS)/Busy Lamp Field (BLF) Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 1-3 Add-On Module (ADM) Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 1-4 Cable Distance Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 1-5 Example of Port Allocation on an ELC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 1-6 Port Designation for DSS/BLF Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 1-7 DSS Key Allocation (DSS/BLF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 1-8 Example of Port Designation for Add-On Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 1-9 Line/Feature Access Key Allocation (Add-ON Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 2-1 Connection Diagram for the DSS/BLF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 2-2 Connection Diagram for the Add-On Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 2-3 Example of Cable Lead Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 3-1 Example of Data Programming for DSS/BLF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 3-2 DSS Key Assignment for DSS/BLF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 3-3 Example of Data Programming for Add-On Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 3-4 DSS Key Assignment for Add-On Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

LIST OF TABLES Table TitlePag e ND-70684 (E) LIST OF TABLES Page v Revision 1.0 Table 1-1 Relationship between the Mode Designation and the Mounting Level Numbers . . . . . . . . . . . . . . 4 Table 1-2 System Specifications for DSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table 1-3 Cable Distance Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table 1-4 Level Assignment Conditions for DSS/BLF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Table 1-5 Level Assignment Conditions for the Add-On Module Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

LIST OF TABLES ND-70684 (E) Pag e vi Revision 1.0 This page is for your notes.

ND-70684 (E) CHAPTER 1 Page 1 Revision 1.0 CHAPTER 1 OVERVIEW 1. General This manual provides technicians with information about the Direct Station Selection (DSS) console shown in Figure 1-1 below. To complete installation tasks, refer to the NEAX2400 IMX Installation Manual for the PBX system to which the DSS console is connected. When the DSS console is located in a Distributed Access Unit (DAU), the NEAX2400 IMX Installation Manual for the DAU is also required. Figure 1-1 Outer View of DSS 000504030201 545958575655 485352515049 424746454443 364140393837 303534333231 242928272625 182322212019 121716151413 061110090807

CHAPTER 1 ND-70684 (E) Page 2 Revision 1.0 OV E RV I E W How to Follow This Manual 2. How to Follow This Manual The contents of this manual are: • CHAPTER 1 (OVERVIEW) This chapter explains how the DSS console is used, and the system specifications for the DSS. CHAPTER 2 (INSTALLATION PROCEDURE) This chapter explains how to install a DSS console and contains cabling diagrams showing how to connect the console to a PBX. CHAPTER 3 (OFFICE DATA ASSIGNMENT) This chapter explains how to program the Office Data used by the DSS. A sample office data assignment sheet is shown in this chapter. To plan your data assignment, blank sheets for each DSS-related command are included at the end of Chapter 3. Note:The word Distributed Access Unit (DAU) in this manual can be replaced with Digital Remote Unit (DRU).