1. General Function
The PH-IO24 (IOC) circuit card supplies the system with a serial interface, which conforms to RS-232C,
between external equipment such as the Maintenance Administration Terminal (MAT), Station Message
Detail Recording System (SMDR), Message Center Interface (MCI). Property Management System
(PMS). The relationship between the IOC card and the associated cards is as follows, when...

Page 82

ND-70182 (E) CHAPTER 2
Page 67
Revision 4.0
PH-IO24
Input/Output Controller
2. Mounting Location/Condition
The IOC cards can be accommodated in the shaded slots (02, 03) as shown below.
Note:When using Business system and Hotel system, prepare the circuit card for each system.
3. Face Layout of Lamps, Switches and Connectors
The face layout of lamps, switches and connectors on this circuit card is shown in Figure 2-25.
Figure 2-25   Face Layout of PH-IO24 (IOC) Card
LPMMounting Module
00   01    02    03...

Page 83

CHAPTER 2 ND-70182 (E)
Page 68
Revision 4.0
PH-IO24
Input/Output Controller
4. Lamp Indications
The table below shows lamp indications on this circuit card.
5. Switch Settings
The following is a brief description of the switches on this circuit card. When a switch has a standard set-
ting, it is indicated with “×” in the table below.
LAMP NAME COLOR DESCRIPTION
OPE/MB Green This circuit card is operating normally.
Red This circuit card is placed in the make busy state.
IOC ALM Red Clock down WDT alarm...

Page 84

ND-70182 (E) CHAPTER 2
Page 69
Revision 4.0
PH-IO24
Input/Output Controller
6. External Interface
As illustrated below, the “68PH S 2PORTS CA-A” cable is required to connect external equipment such as
the MAT, SMDR, MCI and PRT.
Figure 2-26   External Cable Connection for PH-IO24 (IOC)
 Securely insert the connector of the 68PH S 2PORTS CA-A into the appropriate MISC connector. Refer to the table listed below.
The relationship between the MISC connectors and the mounting 
slot of the IOC (PH-IO24)...

Page 85

CHAPTER 2 ND-70182 (E)
Page 70
Revision 4.0
PH-IO24
Input/Output Controller
7. Switch Setting Sheet
SWITCH
NAMESWITCH SHAPE REMARKS
MB
MBR
SW50Meaning of SW50-1:
ON:
OFF:This card is used as the No. 1 circuit card.
This card is used as the No. 0 circuit card.
1
ON
234 

Page 86

ND-70182 (E) CHAPTER 2
Page 71
Revision 4.0
PH-M22
MMC
PH-M22
MMC
1. General Function
The main functions of the PH-M22 circuit card are:
To collect the key setting information on the TOPU of the ISW and send the information to the ISW/
the other LNs, depending on the ISEL key setting on the ISW.
To collect various alarm information from all the IMGs/ISW and activate MJ/MN LED on the TOPU
display.
This circuit card is used for the IMX-U system.
Figure 2-27   Location of PH-M22 (MMC)
PZ-DK222
       (TOP...

Page 87

CHAPTER 2 ND-70182 (E)
Page 72
Revision 4.0
PH-M22
MMC
2. Mounting Location/Condition
This circuit card can be mounted in the shaded slots shown below.
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors are shown in Figure 2-28.
Figure 2-28   Face Layout of PH-M22 (MMC)
LPMMounting Module
00   01    02    03    04    
MMCCPRAQ-A/CPRAS-A
CPRAQ-A/CPRAS-A
OPE
MB
CN7
CN6
CN5
CN4
CN3
CN2
CN1
CN0
KEY 

Page 88

ND-70182 (E) CHAPTER 2
Page 73
Revision 4.0
PH-M22
MMC
4. Lamp Indications
The contents of lamp indications on this circuit card are shown in the table below.
5. Switch Settings
Switch settings on this circuit card are shown in the table below.
LAMP NAME COLOR STATE
OPE Green Lights when this circuit card is in operation.
SWITCH 
NAMESETTINGSTANDARD 
SETTINGMEANING
MBUP Circuit Card make-busy
DOWN×Circuit Card make-busy cancel 

Page 89

CHAPTER 2 ND-70182 (E)
Page 74
Revision 4.0
PH-M22
MMC
6. External Interface
Figure 2-29   Connection of Alarm Indicating Panel
01 02 03 04 05 01 02 03 04 05
 1 
 2 
 3 
4 
5 
6 
7 
8 
9 
10 
11 
12MPALM 
 
EXTAA 
 
BELAA 
- 
MNAA 
SUPAA 
MJAA 26 
 27 
 28 
 29 
 30 
 31 
 32 
 33 
 34 
 35 
 36 
 37 
 
MNBA 
SUPBA 
MJBABELAA 
MNAA 
SUPAA 
MJAA 
MNBA 
SUPBA 
MJBA 
   RPT1(G) 
   RPT0(-48V)MDF
MJ/MN/BELL -48V 
(RPT0)G 
(RPT1)
AUDIBLE AND VISUAL 
ALARM INDICATING PANEL
MDFMJ 
MN 
BELL (BASEU) LPM
MISC0A...

Page 90

ND-70182 (E) CHAPTER 2
Page 75
Revision 4.0
PH-M22
MMC
7. Switch Setting Sheet
SWITCH NAME SWITCH SHAPE REMARKS
MBNote:Normal operating mode is down.ON 