CHAPTER 2 ND-70182 (E) Page 36 Revision 4.0 SN1455 CPRAQ-A/SN1531 CPRAS-A CPU Board 5. Switch Settings Note:Make-busy of this circuit card is not allowed while the Floppy Disk Drive or Hard Disk Drive is being accessed. SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW (PWR)—ON×PWR is supplied to the CPR. OFF PWR is not supplied to the CPR. MB Note (FDD/HDD)—ON (Up) Make-busy of the FDD/HDD. OFF (Down)×Normal setting. MBR (DSP)—ON (Up)Make-busy Request of the CPR in which GT is located. OFF...
Page 52
ND-70182 (E) CHAPTER 2 Page 37 Revision 4.0 SN1455 CPRAQ-A/SN1531 CPRAS-A CPU Board Note: The SENSE switch designates the CPR processing status. The new processing status starts when the CPRRST switch on the DSP is pressed while setting the SENSE switch. SWITCH NAMESETTINGSTANDARD SETTINGMEANING SENSE (DSP) Note1The following three processes are executed at the FDD/HDD. HD formatted File copied from FDD to HD Directory created on the HD 2×On-line mode. 3 File copied from FDD to HD within the...
Page 53
CHAPTER 2 ND-70182 (E) Page 38 Revision 4.0 SN1455 CPRAQ-A/SN1531 CPRAS-A CPU Board 6. External Interface See the NEAX2400 IMX Installation Manual. 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS SW (PWR) MB (PWR:PZ-PW106) MB (FDD/HDD) MBR (DSP) SYSTEM SELECT0 (DSP) SYSTEM SELECT1 (DSP) SYSTEM SELECT2 (DSP) SENSE (DSP) ON OFF ON ON ON 1234ON 1234ON5678 1234ON5678
Page 54
ND-70182 (E) CHAPTER 2 Page 39 Revision 4.0 PH-GT10 Input Output Gate PH-GT10 Input Output Gate 1. General Function The PH-GT10 circuit card provides the TSW I/O bus interface for permitting the CPU board to control the TSW, HSW, and PLO cards within the Inter-node Switch Module (ISWM) of the ISW. Additionally, this circuit card is equipped with the copy function to be consistent with the data of TSW I/O bus in both systems (single/dual). This circuit card is used for the IMX-U system. Figure 2-12...
Page 55
CHAPTER 2 ND-70182 (E) Page 40 Revision 4.0 PH-GT10 Input Output Gate 2. Mounting Location/Condition This circuit card can be mounted in the shaded slots shown below. 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors are shown in Figure 2-13. Figure 2-13 Face Layout of PH-GT10 (IOGT) ISWMMounting Module 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 IOGT(#0) IOGT(#1) MB MBR OPE/MB...
Page 56
ND-70182 (E) CHAPTER 2 Page 41 Revision 4.0 PH-GT10 Input Output Gate 4. Lamp Indications The contents of lamp indications on this circuit card are shown in the table below. 5. Switch Settings Standard settings of switches on this circuit card are shown in the table below. 6. External Interface See the NEAX2400 IMX Installation Manual. 7. Switch Setting Sheet LAMP NAME COLOR MEANING TSW ACTGreen Lights when this circuit card is in ACT state. OFF This circuit card is in ST-BY state. Red Lights when this...
Page 57
CHAPTER 2 ND-70182 (E) Page 42 Revision 4.0 PA - P C 9 4 Data Link Multiplexer PA - P C 9 4 Data Link Multiplexer 1. General Function This circuit card mainly provides the two functions: 1) collection of BLF/TGBL information (associated with Attendant/Desk Console operation) from DLKC cards of all nodes in an IMX-U system, and 2) distribution of the collected data to ATI cards of all nodes. While a DLKC card can manage this processing solely on an accommodated node basis, the use of this card makes...
Page 58
ND-70182 (E) CHAPTER 2 Page 43 Revision 4.0 PA - P C 9 4 Data Link Multiplexer 2. Mounting Location/Condition When this circuit card is used in a single configuration. Mount this circuit card in any of the shaded slots Mounting conditions of this circuit card are as follows: 1. This circuit card cannot be mounted in Slot 05, 07, 09, 10, 11, 12, 16, 18, 19, 21, 22, 23. 2. This card is used in odd-number group (G) of the shaded slots above. 3. To used this card, be sure to assign “RT=938” on the ASDT...
Page 59
CHAPTER 2 ND-70182 (E) Page 44 Revision 4.0 PA - P C 9 4 Data Link Multiplexer 3. Face Layout of Lamps and Switches The face layout of lamps and switches is shown in Figure 2-15. Figure 2-15 Face Layout of PA-PC94 (DLMX) 4. Lamp Indications The contents of lamp indications on this circuit card are shown in the table below: LAMP NAME COLOR STATE OPE Green Remains lit while this circuit card is in normal operation. ACTGreen Lights when this circuit card is in a active state. OFF Off when this circuit...
Page 60
ND-70182 (E) CHAPTER 2 Page 45 Revision 4.0 PA - P C 9 4 Data Link Multiplexer 5. Switch Settings Standard settings of switches on this circuit card are shown in the table below. 6. Switch Setting Sheet SWITCH NAMESWITCH No.SETTINGSTANDARD SETTINGMEANING MBUP Circuit card make-busy. DOWN Circuit card make-busy cancel MNT0OFF×Fixed to OFF. 1OFF×Fixed to OFF. 2OFF×Fixed to OFF. 3ON Make-busy-request. OFF Cancel the make-busy-request. MODE0×Standard setting. (TSW fixed connection) 1-7 Not used SWITCH...