Page 121
CHAPTER 2 ND-70182 (E) Page 106 Revision 4.0 PH-SW10 Time Division Switch 2. Mounting Location/Condition This circuit card is mounted in PIM0 in the slot shown below. 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches and connectors is shown below. Figure 2-50 Face Layout of PH-SW10 (TSW) 00 01 02 03 04 05 06 07 08 09 10 11 1213 14 15 16 17 18 19 20 21 22 23 Mounting ModulePIM PIM0 TSW #1 TSW #0 1 2 3 4 5 6 7 8 SW11 TSWACT MUXACT PLOACT MB TSWMBR PLOMB M3SY...
Page 122
ND-70182 (E) CHAPTER 2 Page 107 Revision 4.0 PH-SW10 Time Division Switch 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. LAMP NAME COLOR STATE TSWACTGreen Remains lit while the TSW block is in ACT state. Red Remains lit while the TSW block is in Make-busy state. Off Remains off while the TSW block is ST-BY side. MUXACT Green Remains lit while MUX block is in ACT state. PLOACT Green Remains lit while PLO block is in ACT state. M3SY Green Lights when MUX #3...
Page 123
CHAPTER 2 ND-70182 (E) Page 108 Revision 4.0 PH-SW10 Time Division Switch 5. Switch Settings Standard settings for switches on this circuit card are shown in the table below. SYNCGreen Remains lit while the system is synchronized with the network. OFFRemains off when any of the following have occurred. DCS clock failure when receiving the clock signals from the DCS. DTI clock failure when receiving the clock signals from the DTI. Drifting failure ICK GreenLights when the TSW (PA-SW10) internal...
Page 124
ND-70182 (E) CHAPTER 2 Page 109 Revision 4.0 PH-SW10 Time Division Switch Note: When MUX card mode (SW03-4 ON), only MUX and CFT functions are valid. MUX 1 is used for a con- nection to TSW (Don’t use MUX 2, 3). The LED of MUXACT, M0SY, CFT, and PMCA are valid, other LED is not lit. In the case of this mode, only SW03 is valid. SWITCH NAMESWITCH NOSETTINGSTANDARD SETTINGMEANING SW031ON 3-Party Conference Trunk (CFT) is valid. OFF 3-Party Conference Trunk (CFT) is invalid. 2ON Setting of A-law in the...
Page 125
CHAPTER 2 ND-70182 (E) Page 110 Revision 4.0 PH-SW10 Time Division Switch SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW111ON PLO operates as the clock subordinate office. OFF PLO operates as the clock source office. 2ON Digital Clock Supply route zero (DCS 0) is used. OFF Digital Clock Supply route zero (DCS 0) is not used. 3ON Digital Clock Supply route one (DCS 1) is used. OFF Digital Clock Supply route one (DCS 1) is not used. 4ON8 KHz of Frame Head signals are not extracted from the DCS...
Page 126
ND-70182 (E) CHAPTER 2 Page 111 Revision 4.0 PH-SW10 Time Division Switch 6. External Interface When this circuit card is used in “clock subordinate office”, clock signals from DTI, CCT, PRT must be extracted. See Figure 2-52 for more information. When this circuit card is used in “clock source office” cable connections are not necessary. Figure 2-51 PLO Connector Leads Location 2627 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...
Page 127
CHAPTER 2 ND-70182 (E) Page 112 Revision 4.0 PH-SW10 Time Division Switch Figure 2-52 Connecting Route Diagram DCS TSW #1 TSW #0/PRT CCT/DTI CCT/DTI /PRT CCT/DTI /PRT CCT/DTI /PRTPOUT A POUT B POUT A POUT B POUT A POUT B POUT A POUT B DCSA0 DCSB0 DIU0A0 DIU0B0 DIU1A0 DIU1B0 DIU2A0 DIU2B0 DIU3A0 DCSA1 DCSB1 DIU0A1 DIU0B1 DIU1A1 DIU1B1 DIU2A1 DIU2B1 DIU3A1 DIU3B1 PBX MDF Note: The following circuit cards have Clock Output leads for a PLO card: CCT (PA-24CCTA, PA30CCTB), DTI (PA-24DTR, PA-30DTS), and PRT...
Page 128
ND-70182 (E) CHAPTER 2 Page 113 Revision 4.0 PH-SW10 Time Division Switch The front cable connections are shown in Figure 2-53. Figure 2-53 Front Cable Connections for PH-SW10 TDSW #0 MUX #0 MUX #0MUX #1 MUX #1 MUX #1MUX #0 TDSW #1 MT24 TDSW CA-180 MT24 TDSW CA-140 MT24 TDSW CA-90 PIM 3 PIM 2 PIM 1 PIM 0
Page 129
CHAPTER 2 ND-70182 (E) Page 114 Revision 4.0 PH-SW10 Time Division Switch 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS MB TSWMBR PLOMB SW03 SW04 SW11 SW12 ON ON ON 1234ON 1234ON5678 1234ON5678 1
Page 130
ND-70182 (E) CHAPTER 2 Page 115 Revision 4.0 PH-SW12 Time Division Switch PH-SW12 Time Division Switch 1. General Function This circuit card provides the Time Division Switch (TSW) and INT function for the system. Each TSW card is capable of 8192 × 2048 Time Slot (TS) switching for an Interface Module Group (IMG). Four cards allow 8192 × 8192 TS switching for the 4 IMG configuration. The INT is an intermediate circuit of the CPR which controls and administrates the Port Microprocessor (PM) for line/trunk...