NEAX2400 IMX CCIS Features and Specifications Page 176NDA-24222, Issue 3 S-52 Serial Call - CCIS Operating Procedure (cont’d) 5. Station (b1) answers and is connected with Station (c). The HOLD status remains on the Attendant Console. 6. Station (b1) hangs up. On the Attendant Console, the lamps in the loop key section corresponding to the incoming call keep flashing at 60 ipm, and the bell rings. Station (c) receives ringback tone. 7. The Attendant presses the loop key corresponding to the flashing lamps. Station (c) and the Attendant are connected again. The Attendant assists the connection to the next station. Service Conditions 1. If the attendant enters a loop that is already set up for a SERIAL CALL, the service is automatically cancelled. 2. SERIAL CALL is not provided for Station-to-Station calling. 3. SERIAL CALL can be provided on a TENANT [T-12] basis. 4. A called station that has the SERIAL CALL feature activated will automatically recall the attendant if the station switch hook flashes. STN (c) STN (a)ATT [Node A]CCIS [Node B]STN (b1) STN (b2) PUBLIC SWITCHED TELEPHONE NETWORK STN (c) A ATT [Node A]CCIS [Node B]STN (b1) STN (b2) RGRBT RBT PUBLIC SWITCHED TELEPHONE NETWORK
NEAX2400 IMX CCIS Features and Specifications NDA-24222, Issue 3 Page 177 Serial Call - CCIS S-52 Service Conditions (cont’d) 5. This feature is not applicable for tandem connections. 6. The following services cannot be used while SERIAL CALL - CCIS is activated: ATTENDANT CAMP-ON WITH TONE INDICATION - CCIS [A-45] BUSY VERIFICATION - CCIS [B-9] CALL HOLD - CCIS / CALL HOLD - D term[C-6/C-6D] EXECUTIVE RIGHT-OF-WAY [E-8]
NEAX2400 IMX CCIS Features and Specifications Page 178NDA-24222, Issue 3 S-53D Service Display - Dterm - CCIS S-53D Service Display - Dterm - CCIS General Description This feature allows a Dterm user to receive LCD displays corresponding to the various features as they are initiated. Operating Procedure Each display is automatically generated when a service feature is initiated. Service Conditions 1. Each display is controlled by system data and is produced accordingly. A display may be allowed or denied in system data programming on a per-system basis. 2. The contrast on the LCD display panel is controlled by the UP/DOWN key of the D term. Press the UP key for a darker image or the DOWN key for a lighter image.
NEAX2400 IMX CCIS Features and Specifications NDA-24222, Issue 3 Page 179 Simultaneous Voice and Data Transmission - CCIS S-54 S-54 Simultaneous Voice and Data Transmission - CCIS General Description This feature allows a voice signal and a digital data signal of up to 56 Kbps to be transmitted simultaneously through CCIS, via a Dterm equipped with a Data Adapter. Voice and data calls can be placed to different locations. Operating Procedure To place a data call to a terminal already connected by a voice call: 1. Press the DTX key on the Dterm. The DTX lamp lights and the DATA lamp flashes. The LCD displays: 2. When the data call is connected, the DATA lamp and DTX lamp will light steadily. The LCD displays: To place a data call to a Data Adapter of Data Module when not connected to a voice call or to a different data station: 1. Press the DATA key. The DATA lamp lights steadily. The LCD displays: 2. Dial the desired number. The DATA lamp will flash. The LCD displays: 3. When the data call is answered, the DATA lamp will light steadily. The LCD displays: Service Conditions 1. An asynchronous Data Adapter and Data Module are available at speeds of up to 19.2 Kbps. 2. The Data Adapter and Data Module require a 117V AC wall outlet. 3. The Data Adapter mounts in the base of the D term telephone set. Additional hardware is required. DATA (Time Display)XXXX Data Port READY D (Time Display)XXXX Data Port DATA (Time Display) DATA (Time Display)XXXXXXXX Called Number READY D (Time Display)XXXX Data Port
NEAX2400 IMX CCIS Features and Specifications Page 180NDA-24222, Issue 3 S-54 Simultaneous Voice and Data Transmission - CCIS Service Conditions (cont’d) 4. If the Dterm DTX button is pressed when connected station-to-station within the CCIS network, the voice line connection is switched to MODEM POOLING - CCIS [M-39] from the Dterm Data line. Interactions 1. It is recommended that the numbering plan be set up so that voice numbers occupy one level and data levels occupy another. Therefore, a voice number of 310 can have a data number of 210. 2. The LEN of the data extension is assigned as TEC 13. The voice LEN is assigned as a TEC 12. The voice and data LENs are associated as follows: 3. The data extension number is automatically assigned to the key programmed as DATA. 4. For Data Terminals, assign RSCs that allow access to the routes to be used for data transmission, and the SFC or the data terminal should include SFI 11 = 0, Data Privacy. 5. Only DTE-to-DTE direct internal connections are possible. The DTE would then be set for AUTO answer and the DTX key could not be used. 6. This programming description is limited only to the station programming. Voice Data LEN xx x xx 0 LEN xx x xx 4 LEN xx x xx 1 LEN xx x xx 5 LEN xx x xx 2 LEN xx x xx 6 LEN xx x xx 3 LEN xx x xx 7 MG U GP LV MG U GP LV
NEAX2400 IMX CCIS Features and Specifications NDA-24222, Issue 3 Page 181 Single-Digit Station Calling - CCIS S-55 S-55 Single-Digit Station Calling - CCIS General Description This feature allows single-digit station numbers to be assigned. Operating Procedure 1. Lift the handset; receive dial tone, 2. Dial the single-digit station code, 3. The called station will ring. Service Conditions 1. The single-digit number must not duplicate the first digit of: a.) Trunk Access Codes b.) Feature Access Codes c.) Other Telephone Numbers 2. Timing Start is not available with this feature. Interactions 1. An entire number level is eliminated for each station with one-digit access. Do not plan to have more than one or two such phones in a system. 2. The Attendant Console Busy Lamp Field (BLF) is not available for this feature.
NEAX2400 IMX CCIS Features and Specifications Page 182NDA-24222, Issue 3 S-56 Station-Controlled Conference - CCIS S-56 Station-Controlled Conference - CCIS General Description This feature allows any PBX station to establish a conference through CCIS. The conference can be any combination of stations and trunks (on-network and off-network parties). Operating Procedure To establish a conference call: 1. The user wishing to establish the conference (Conference Leader) calls each party to be included and advises them of the conference. 2. All participating stations then call the conference extension number or the Conference Leader, who will transfer them to the conference number. 3. The conferees are automatically connected. 4. Any push-button station within the conference can dial “9” to lock out additional parties using the MMCB model. To release from a conference call: 1. If any pushbutton station in the conference dials “0”, all conferees will be disconnected. Otherwise, the conference is terminated after all parties have hung up. 2. Any individual conferee can release from the conference call by hanging up. All other conferees will remain connected. Using the PA-CFTB, the conference leader can dial “0” to lock out additional parties. Dialing “0” again will allow more parties to be connected. If the conference leader dials “#”, all conferences will be disconnected. Otherwise, the conference is terminated after all parties have hung up. Service Conditions 1. Conference Units are designed to provide adequate amplification, but the condition of the Central Office connections will affect transmission. 2. Conference Unit extension numbers should be placed in a STATION HUNTING-TERMINAL [S-9] group. Only the Pilot number of this group should be published. 3. Each Conference Unit can provide up to an eight-party conference. 4. Override services, such as BUSY VERIFICATION [B-3, B-9], ATTENDANT OVERRIDE [A-7], or EXECUTIVE RIGHT-OF-WAY [E-1, E-8], are denied to stations engaged in a conference call. 5. The following additional hardware is required: External Conference Unit MMCB PA-16LCQ or PA-16LCBE circuit card 6. The PA-CFTB may be used instead of the MMCB. The PA-16LCBE or PA-16LCQ is not required by the PA-CFTB. Interactions The PA-16LCBE or PA-16LCQ circuit card provides a momentary open for all 16 circuits. This is required to provide a release signal when line circuits are connected to external equipment such as conference and page units. This keeps reorder tone from being sent to the conference unit. This is not used in conjunction with a PA-CFTB.
NEAX2400 IMX CCIS Features and Specifications NDA-24222, Issue 3 Page 183 Station-to-Station Calling - CCIS S-57 S-57 Station-to-Station Calling - CCIS General Description This feature allows any user to dial another station directly, through CCIS, without operator assistance. Operating Procedure 1. Lift the handset; receive dial tone. 2. Dial the desired telephone number. Service Conditions 1. The maximum number of digits per telephone number is eight. 2. Either Calling-Party Release or First-Party Release can be selected on a system basis. 3. Inter-node STATION-TO-STATION CALLING - CCIS is based on the Route Restriction Class of the calling and called parties. Interactions 1. The ATNR command is required for STATION-TO-STATION CALLING - CCIS. 2. The normal 5 dB PAD loss inserted for STATION-TO-STATION CALLING - CCIS may be eliminated on a per-station basis. For these stations, assign a Service Feature Class that allows SFI 50. Remove 5 dB pad for Off-Premises Extensions, OPX.
NEAX2400 IMX CCIS Features and Specifications Page 184NDA-24222, Issue 3 S-58 Station-to-Station Calling - Operator Assistance - CCIS S-58 Station-to-Station Calling - Operator Assistance - CCIS General Description This feature allows a user to call another station, through CCIS, with the assistance of the Attendant Console operator. Operating Procedure To place a station-to-station call through the Attendant Console: 1. Lift the handset; receive dial tone. 2. Dial the operator access code (normally “0”). 3. Give the desired telephone number to the Attendant. 4. The Attendant dials the telephone number. 5. The calling and called parties are connected when the Attendant presses the RELEASE key. Service Conditions 1. The Attendant can drop out of the connection before or after the called party has answered. 2. When Loop Release is in service, AUTOMATIC RECALL [A-8] will not be activated if the called station does not answer. 3. The Attendant can connect the calling party to a fully restricted station. 4. STATION-TO-STATION CALLING-OPERATOR ASSISTANCE - CCIS is based on the Route Restriction Class of the calling and called station. Interactions 1. The ATNR command is required for STATION-TO-STATION CALLING-OPERATOR ASSISTANCE - CCIS. 2. The normal 5 dB PAD loss inserted for STATION-TO-STATION CALLING-OPERATOR ASSISTANCE - CCIS may be eliminated on a per-station basis. For these stations, assign a Service Feature Class that allows SFI 50. Remove 5 dB pad for Off-Premises Extensions, OPX. 3. The Attendant Console must first be provided. 4. ATTENDANT CAMP-ON WITH TONE INDICATION [A-1, 45]: The Attendant Console cannot camp- on a station-to-station call.
NEAX2400 IMX CCIS Features and Specifications NDA-24222, Issue 3 Page 185 Step Call - CCIS S-59 S-59 Step Call - CCIS General Description This service feature allows Inter-Office Step Call when the calling station and the called station belong to different PBX’s in the CCIS network. Operating Procedure 1. While Station (a1) and (b1) are engaging in a call, Station (a2) goes off-hook and receives dial tone. 2. Station (a2) dials No. 2220 for Station (b1) and receives busy tone. 3. Station (a2) dials the lowest digit of the number (‘5’ of N = 2225) of Station (b2) and receives ringback tone while Station (b2) is rung. 4. Station (b2) answers and is connected with Station (a2). Service Conditions 1. This service feature can be provided for all stations and the ATTENDANT CONSOLE(s) [A-3]. 2. STEP CALLING can be in any order, 1-9 or 9-1. 3. If the second selected station is also busy, STEP CALLING can continue until a station rings. 4. If a station is set for any type of CALL FORWARDING-ALL CALLS, BUSY LINE, DON’T ANSWER, the CALL FORWARDING [C-2, C-3, C-5] will take effect. STN (a1) STN (a2)[Node A][Node B] CCIS DTSTN (b1): 2220 STN (b2): 2225 DT STN (a1) STN (a2)[Node A][Node B] CCIS BTSTN (b1): 2220 STN (b2): 2225 2220 CCIS [Node A][Node B]STN (b1): 2220 STN (b2): 2225 RBTRG CCIS [Node A] [Node B]STN (b1): 2220 STN (b2): 2225 STN (a2) STN (a1)