NUMBER SHARING NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) Page 26NDA-24274, Issue 1.0 Service Conditions 1. Calling Number Display to Dterm When Dterm-A is connected to the DtermPSII (Sub Station), the station number of the Dterm(Main Station) instead of DtermPSII (Sub Station) is displayed on Dterm-A. a. Main Station number is always displayed even if D termPSII (Sub Station) is called up by directly dialing DtermPSII’s number irrespective of forwarding being set. b. As for Name Display, D termPSII name is displayed to calling Dterm-A. The same name can be assigned to DtermPSII/Dtermby CM77. 2. Calling Number Display through CCIS When D term-A is connected to the DtermPSII (SubStation) through CCIS, the station number of the Dterm (Main Station) instead of DtermPSII (SubStation) is displayed on Dterm-A. a. Main Station number is always displayed even if D termPSII (Sub Station) is called up by directly dialing DtermPSII’s number irrespective of forwarding being set. b. As for Name Display, D termPSII name is displayed to calling Dterm-A. The same name can be assigned to DtermPSII/Dtermby CM77. 3. When a call is originated from D termPSII (SubStation) to ISDN, the Sub Station number is sent out. 4. When a call is originated from D termPSII (SubStation) or a call is terminated to DtermPSII (SubStation), service class and tenant number assigned to DtermPSII (Sub Station), are referred. Note:Do not assign data asfollows; - Main Station : Allow to access ISDN - Sub Station : Restrict to access ISDN In this case, D termPSII is not able to access ISDN when forwarding is set from Dterm. 5. When a call is originated from the DtermPSII (Sub Station), billing information is recorded as a call originated from the Dterm(Main Station). When a call is transferred from the D termPSII (SubStation) to the Voice Mail System by Call Forwarding - All Calls/Busy Line/Don’t Answer, the voice mail is recorded on the mail box of the Dterm(Main station). The system controls Message Waiting Indication on both the Dterm(Main Station) and DtermPSII (Sub Station). 6. When a call is terminated to Main Station while this feature is setting, services assigned to Main Station, such as Call Forwarding - All Calls/Busy Line/Don’t Answer/Station Hunting/UCD/DND, are invalid. The services assigned to D termPSII (Sub Station) are valid. 7. When a call is terminated to D termPSII (Sub Station) but the DtermPSII (Sub Station) is busy, the following services can be assigned to DtermPSII (Sub Station). CallForwarding-BusyLine CallBack Call Waiting Whisper Page Attendant Camp On Executive Right of Way
OUT OF ZONE INDICATION NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) NDA-24274, Issue 1.0 Page 27 OUT OF ZONE INDICATION General Description When a DtermPSII user moves out of the service area and the electric field strength becomes weak, this feature notifies it to the user with the warning tone and the LCD display. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure No manual operation is required. Service Conditions 1. When a DtermPSII user turns the power on while he/she is out of the service area or when the user moves out of the service area while idle, Out of Zone Indication is displayed. 2. When the electric field strength becomes so weak that communication cannot be continued, Automatic Release - Out of Zone Calls is activated.
OVERLAP DIALING NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) Page 28NDA-24274, Issue 1.0 OVERLAP DIALING General Description This feature allows a DtermPSII user to receive dial tone and dial the desired number to originate a call. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure To originate a call: 1. Press the L1 or L2 key and receive dial tone. 2. Dial the desired number. The dialed numbers will be displayed on the LCD. Service Conditions 1. A maximum of 24 digits (numbers 0 to 9, #, and *) can be dialed. A maximum of 11 digits can be displayed on the LCD. 2. The D termPSII user can dial the number before hearing dial tone. 3. The interdigit timer after receiving dial tone is 10 seconds, and if no number is dialed within this period, the user receives reorder tone. 4. If the interdigit timer expires while the user is dialing the number, the numbers dialed before the timer will be sent out. 5. PS Authorization is activated for every call origination.
PS AUTHORIZATION NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) NDA-24274, Issue 1.0 Page 29 PS AUTHORIZATION General Description This feature is to confirm the identity of a DtermPSII to avoid an unauthorized DtermPSII from accessing the system. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure No manual operation is required. The D termPSII identity is confirmed automatically by checking whether the DtermPSII possesses the key information unique to each DtermPSII. This check is performed between the IVS-WCS and the DtermPSII. Service Conditions 1. This feature is activated in the following circumstances: a. when the D termPSII user originates a call. b. when a call terminates to the D termPSII. c. when Handover service is activated. d. when the D termPSII registers its location to the system (when idle).
PS LOCATION REGISTRATION NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) Page 30NDA-24274, Issue 1.0 PS LOCATION REGISTRATION General Description This feature allows the IVS-WCS to supervise the location of each DtermPSII, upon receiving the location registration request, to allow call termination. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure No manual operation is required. Service Conditions 1. This feature is activated every time a DtermPSII enters a different paging area. A maximum of 32 calling areas can be installed in an IVS-WCS. 2. A maximum of 128 zone transceivers can be installed in a calling area. 3. PS Authorization is activated every time the D termPSII requests location registration.
PRESET DIALING NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) NDA-24274, Issue 1.0 Page 31 PRESET DIALING General Description This feature allows a DtermPSII user to confirm the number to be dialed before originating acall. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure To originate a call: 1. Dial the desired number. The number will be stored and displayed on the LCD. 2. After confirming the number, press the L1 or L2 key. The number will be displayed on the LCD throughout the conversation. Service Conditions 1. A maximum of 24 digits (numbers 0 to 9, #, *, and pause) can be stored. A maximum of 11 digits can be displayed on the LCD. When more than 12 digits are dialed, the digits exceeding 12 move from right to left, displaying only the mostrecently dialeddigits. 2. If a wrong number is dialed, press the FNC key. The number just dialed will be cleared. If the FNC key is pressed for more than two seconds, the numbers will be cleared successively. Also, if no number is entered for 20 seconds, the service is cleared, and the D termPSII returns to the idle state (stand by status). 3. If the user dials a number after pressing the L1 or L2 key, it will be recognized as a DTMF signal sending. 4. PS Authorization is activated for every call origination.
RADIO CHANNEL CHANGEOVER NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) Page 32NDA-24274, Issue 1.0 RADIO CHANNEL CHANGEOVER General Description This feature is to supervise and changeover the channel automatically to avoid the interference and to maintain the speech quality. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure No manual operation is required. Service Conditions 1. There is no interruption in the speech when this feature is activated. 2. The new channel is assigned to the party which has moved into the service area. 3. When there is no idle channel, the call is continued on the same channel until communication becomes unavailable, then Automatic Release - Out of Zone Calls is activated.
SPEECH ENCRYPTION NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) NDA-24274, Issue 1.0 Page 33 SPEECH ENCRYPTION General Description This feature protects a call from being tapped. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure No manual operation is required. Service Conditions 1. This feature is activated for every originating call from a DtermPSII and every terminating call to a Dterm PSII. For every call, the encryption assignment message is sent from the DtermPSII to the zone transceiver. 2. Speech Encryption is automatically activated throughout the call. Encryption cannot be canceled during the call.
SPEED DIAL - PS NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) Page 34NDA-24274, Issue 1.0 SPEED DIAL - PS General Description This feature allows a DtermPSII user to dial the certain frequently called numbers using two-digit abbreviated call codes. Configuration Application IVS Wired for Wireless and PBX Adjunct Operating Procedure Refer to Speed Dial in the DtermPSII User Guide. Service Conditions Refer to the DtermPSII User Guide.
VOICE MAIL INDICATION NEAX2000 IVS2 WCS Features and Specifications (for Dterm PSII) NDA-24274, Issue 1.0 Page 35 VOICE MAIL INDICATION General Description When a message is mailed in the DtermPSII, an indication of the envelop icon is displayed in the LCD of the DtermPSII. Configuration Application IVS Wired for Wireless Operating Procedure To retrieve a voice mail message 1. Press the L1 or L2 key and receive dial tone. 2. Dial the VMS station number and receive ringback tone. 3. Follow the instruction given by the VMS. 4. Listen to the message. Service Conditions 1. An envelop icon is displayed only when a message is mailed to the L1(My Line PS). 2. VMI (Voice Mail Indication) is displayed only for a message mailed to My Line. When the message is mailed, the PBX sends a VMI signal to D termPSII only once. At that time, if PS is out of zone or PS’s power is off, the VMI is not displayed until the DtermPSII connects to the PBX and disconnects again. 3. When the message is mailed to the My Line PS, the PBX sends an envelop icon on signal to D termPSII only once. At that time, if PS is out of zone or PS’s power is off, the envelop icon is not displayed until the Dterm PSII connects to the PBX and disconnects again. 4. Other service conditions are in common with those of “Message Waiting” in Business/Hotel/Data Features and Specifications.