 NEAX2000 IVS2 Q-SIG System ManualPage 34  ND-70923 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
DTI Assignment
DESCRIPTION DATA
Assign a trunk route to each Q-SIG trunk 
used for voice channel (B Channel), and 
also to signaling channel (D Channel). 
(1)
(2)YY=00 
000-255: Trunk No. assigned by CM07 
YY=01 
00-63: Trunk Route No.
NOTE 1:DTI route must be separated
from analog trunk routes. 
NOTE 2:The trunk routes for D Channel
must be different from the trunk
routes for B Channel.
Assign the...

Page 42

CHAPTER 3  SYSTEM DATA PROGRAMMING
DTI Assignment
NEAX2000 IVS2 Q-SIG System Manual    
ND-70923 (E), Issue 1.0   Page 35
DESCRIPTION DATA
Assign the trunk route data to the DTI 
route number assigned by CM30 Y=00.
NOTE:CM35 YY=00, 04, 05, 09, 15 and
19 should be assigned to only
the B Channel trunk routes.
For D Channel trunk route, no
data setting is required.
(1)
(2)YY=00 Kind of Trunk Route
00-63: B Channel Trunk Route No. 
04: Tie Line trunk

(1)
(2)YY=04 
Answer Signal from distant office
00-63:...

Page 43

 NEAX2000 IVS2 Q-SIG System ManualPage 36  ND-70923 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
DTI Assignment
DESCRIPTION DATA
YY=19 DTI PAD
[For North America/Other Countries]
Assign Q-SIG to the B Channel trunk 
routes and the D Channel trunk route.
(1)
(2)YY=90 
Assignment of DTI route for Q-SIG
00-63:  B Channel /D Channel Trunk 
Route No. 
5: Q-SIG (ETS300 172)
Assign the LAPD mode of the D Channel 
trunk route.
This data setting must not be identical 
with the opposite PBX.
If the opposite...

Page 44

CHAPTER 3  SYSTEM DATA PROGRAMMING
DCH Assignment
NEAX2000 IVS2 Q-SIG System Manual    
ND-70923 (E), Issue 1.0   Page 37
DCH ASSIGNMENT
DESCRIPTION DATA
Assign an AP number to the DCH card. 
The AP number must match the SENS 
switch setting on the DCH card. 
(1)
(2)Y=0
04-15, 20-31: AP No. 
32: DCH card for Q-SIG
Assign the DCH number to the AP 
number of DCH assigned by CM05. 
(1)
(2)YY=08 
0-7: DCH No.
04-15, 20-31: AP No. assigned by 
CM05 Y=0
Assign the DCH number to the Q-SIG 
trunk route...

Page 45

 NEAX2000 IVS2 Q-SIG System ManualPage 38  ND-70923 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Tandem Connection Assignment
TANDEM CONNECTION ASSIGNMENT
To provide Tandem Connection (Tie Line to Q-SIG, Q-SIG to Tie Line), do the following
programming.
DESCRIPTION DATA
Specify whether the busy tone is sent to a 
calling party of Q-SIG when a called party 
is busy in the tandem connection (Q-SIG 
to COT).(1)
(2)407
0  : Available (BT)
1  : Not available (RBT)
Specify the combination of trunk routes...

Page 46

CHAPTER 3  SYSTEM DATA PROGRAMMING
Connected Destination Indication Assignment
NEAX2000 IVS2 Q-SIG System Manual    
ND-70923 (E), Issue 1.0   Page 39
CONNECTED DESTINATION INDICATION ASSIGNMENT
To send own office number with the answering station (single line telephone, Dterm) number to
the calling party, do the following programming.
DESCRIPTION DATA
Assign the own office number sent with 
the answering station number, if required.
(1)
(2)YY=01
0-7: DCH No. 
0-999: Own Office No. 
START
END
CMA9
DCH...

Page 47

NEAX2000 IVS2 Q-SIG System Manual    
ND-70923 (E), Issue 1.0   Page 41
CHAPTER 4
CIRCUIT CARD
INFORMATION
This chapter explains the mounting location, the meaning of lamp
indications, and the method of switch settings of each circuit card for
the Q-SIG. 

Page 48

 NEAX2000 IVS2 Q-SIG System ManualPage 42  ND-70923 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
How to Read This Chapter
HOW TO READ THIS CHAPTER
This chapter explains each circuit card used in this system about the following items.
Explanations are given in alphabetical order of the circuit card names within each circuit card
category (Control, Application Processor, and Line/Trunk).
(1) Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors of each circuit...

Page 49

CHAPTER 4  CIRCUIT CARD INFORMATION
Mounting Location of Circuit Card
NEAX2000 IVS2 Q-SIG System Manual    
ND-70923 (E), Issue 1.0   Page 43
MOUNTING LOCATION OF CIRCUIT CARD
This section explains the conditions for mounting circuit cards for the Q-SIG.
Figure 4-1 shows circuit card mounting slots allocated in the PIM.
Figure 4-1  Mounting Location of Circuit Card
*1: PN-CP14 (MP) card on the MP12 slot on PIM0.
*2: The following application processor card mounted on the AP00-AP11 slots on PIM0-7....

Page 50

 NEAX2000 IVS2 Q-SIG System ManualPage 44  ND-70923 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
List of Required Circuit Card
LIST OF REQUIRED CIRCUIT CARD
Table 4-1 shows the required circuit cards to be explained in this section.
*MB = Make Busy
Table 4-1  List of Required Circuit Card
NAME
(FUNCTIONAL
NAME)LAMP
X: PROVIDED
–: NOT 
PROVIDEDSWITCH
X: PROVIDED
–: NOT 
PROVIDED
EXTRACTION/
INSERTION WITH 
POWER ON
X: ALLOWED
: ALLOWED 
AFTER MB*
–: NOT 
ALLOWEDREFERENCE
PAGE
PN-CP14 (MP) X X –Page...