NEC Neax 2000 Ivs2 Q-Sig System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Q-Sig System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
NEAX2000 IVS2 Q-SIG System ManualPage 14 ND-70923 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Service Features SERVICE FEATURES Connected Destination Indication This feature allows the LCD on the calling station/Attendant Console to indicate the connected destination number (answering station number) and the sub-address sent from the opposite office. Figure 1-9 Connected Destination Indication The LCD does not indicate the answering station number and sub-address number if the numbers are not...
Page 22
CHAPTER 1 GENERAL INFORMATION Service Features NEAX2000 IVS2 Q-SIG System Manual ND-70923 (E), Issue 1.0 Page 15 If the sub-address exceeds 8 digits, the first 8 digits and “*” are indicated on the Dterm LCD. “*” means existence of more than 8 digits. The sub-address of the answering station is not indicated on the Attendant Console LCD. If the answering station number exceeds 6 digits, the last 6 digits are indicated on the Attendant Console LCD. It can be specified to each station...
Page 23
NEAX2000 IVS2 Q-SIG System ManualPage 16 ND-70923 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Service Features Transit Counter Relaying Transit counter is used as the information which informs the number of stages on tandem connection. On the Q-SIG network, the transit Counter 0 is sent from the calling office. The tandem office sends the transit counter to the destination office adding 1 to the value of received transit counter. In this manner, the transit counter value increases according to the...
Page 24
NEAX2000 IVS2 Q-SIG System Manual ND-70923 (E), Issue 1.0 Page 17 CHAPTER 2 INSTALLATION This chapter explains the hardware installation procedure to provide Q-SIG interface on the PBX.
Page 25
NEAX2000 IVS2 Q-SIG System ManualPage 18 ND-70923 (E), Issue 1.0 CHAPTER 2 INSTALLATION Precautions PRECAUTIONS STATIC ELECTRICITY GUARD You must wear a grounded wrist strap to protect circuit cards from static electricity. Figure 2-1 Static Electricity Guard (1 of 2) WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD WHEN HOLDING A CIRCUIT CARD PBX WRIST STRAP FRAME GROUND SCREW CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
Page 26
CHAPTER 2 INSTALLATION Precautions NEAX2000 IVS2 Q-SIG System Manual ND-70923 (E), Issue 1.0 Page 19 Figure 2-1 Static Electricity Guard (2 of 2) WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD WHEN CARRYING A CIRCUIT CARD The mark shown below is attached to the sheet for the work in which circuit cards are handled. When engaging in such work, the installer must be careful not to cause damage by static electricity. WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE....
Page 27
NEAX2000 IVS2 Q-SIG System ManualPage 20 ND-70923 (E), Issue 1.0 CHAPTER 2 INSTALLATION Precautions Caution You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. PBX
Page 28
CHAPTER 2 INSTALLATION Required Equipment NEAX2000 IVS2 Q-SIG System Manual ND-70923 (E), Issue 1.0 Page 21 REQUIRED EQUIPMENT Table 2-1 shows the equipment required to provide Q-SIG interface to the system. Table 2-1 Required Equipment for Q-SIG EQUIPMENT DESCRIPTION QUANTITY REMARKS PN-30DTC-A (30-DTI) (Australia/Japan)30-Channel DTI Card 1-4 PN-24DTA-C (24-DTI) (U.S.)24-Channel DTI Card 1-4 PN-SC01 (DCH)D Channel Handler Card 1-4 PZ-M542/M557(CONN) Coaxial Cable Connection Card 1-4 2...
Page 29
NEAX2000 IVS2 Q-SIG System ManualPage 22 ND-70923 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure INSTALLATION PROCEDURE Install the equipment for Q-SIG according to the procedure in Figure 2-2. Figure 2-2 Installation Procedure for Q-SIG END START MOUNTING DTI AND DCH CARD MOUNTING CONN CARD NOTE:This procedure is required when you provide CONN card to connect a coaxial cable for 24-DTI/30-DTI. DTI CABLE CONNECTION VIA MDF DTI CABLE CONNECTION VIA CONN CARD SELECTION OF PLO Page 23...
Page 30
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 Q-SIG System Manual ND-70923 (E), Issue 1.0 Page 23 Mounting DTI and DCH Card (1) Before mounting the 24-DTI/30-DTI card and DCH card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4,Page 41. (2) Mount the 24-DTI/30-DTI card and the DCH card in the following AP slots on PIM0-PIM7. PIM0: AP00-AP10 slots PIM1-7: AP00-AP11 slots NOTE:The DTI card (DTI0, DTI1) which sends a clock signal to...