NEC Neax 2000 Ivs2 Ccis System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Ccis System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
NEAX2000 IVS2 CCIS System ManualPage iv ND-70918 (E), Issue 1.0 TABLE OF CONTENTS Page CHAPTER 4 CIRCUIT CARD INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 HOW TO READ THIS CHAPTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 MOUNTING LOCATION OF CIRCUIT CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . ....
Page 12
LIST OF FIGURES Figure TitlePage NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page v Figure 1-1 No. 7 CCIS System Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 1-2 Clock Supply Route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 1-3 No. 7 CCIS with DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7...
Page 13
NEAX2000 IVS2 CCIS System ManualPage vi ND-70918 (E), Issue 1.0 LIST OF TABLES Table TitlePage Table 1-1 Card Name and Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 1-2 System Capacity for No. 7 CCIS with Digital Interface . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 1-3 System Capacity for No. 7 CCIS with Analog Interface . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 1-4 Number of Time Slots Required per...
Page 14
Introduction Purpose NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 1 INTRODUCTION PURPOSE This manual explains the installation and programming procedure for providing No. 7 Common Channel Inter-Office Signaling (No. 7 CCIS) system to the NEAX2000 IVS 2/NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER. OUTLINE OF THIS MANUAL This manual consists of five chapters. The contents of CHAPTER 1 through 5 are outlined below. CHAPTER 1 GENERAL INFORMATION This chapter explains the system...
Page 15
NEAX2000 IVS2 Maintenance ManualPage 2 ND-70926 (E), Issue 1.0 Introduction Terms in This Manual TERMS IN THIS MANUAL Usually, PBX system is designated as “PBX” or “system”. When we must distinguish between the PBX systems, they are designated as follows. IVS: NEAX2000 IVS 2/NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER IMX: NEAX2400 IMS (IMX)/NEAX7400 ICS M140MX or more/NEAX7400 IMX M240 or more REFERENCE MANUAL During installation, refer also to the manuals below: Command Manual Describes...
Page 16
NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 3 CHAPTER 1 GENERAL INFORMATION This chapter explains the system outline, the name and functions of circuit cards required, system capacity, time slot assignment condition, system specifications, available service features with No. 7 CCIS, and network structure considerations for CCIS system.
Page 17
NEAX2000 IVS2 CCIS System ManualPage 4 ND-70918 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE The PBX can be interfaced with a Public Network or Tie Line Network by No. 7 CCIS Signaling. For adding No. 7 CCIS to the system, it is necessary to install the 24/30 channel Digital Trunk Interface (DTI) for a digital network or LDT (Loop Dial Trunk)/ODT (2 wire E&M or 4 wire E&M Trunk) for an analog network via a MODEM, and a Phase Locked Oscillator (PLO) for network...
Page 18
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 5 DTI The Digital Trunk Interface (DTI) interfaces the PBX directly to a 24/30 channel PCM transmission line. The DTI has the following functions. For 24-DTI: Unipolar/Bipolar Conversion (AMI Format/B8ZS Format) Signaling Insertion/Extraction Alarm Detection/Insertion Digital PAD on Voice Signal Transmission Loop-Back Test (Local/Remote Loop Back) Cyclic Redundancy Checking (based...
Page 19
NEAX2000 IVS2 CCIS System ManualPage 6 ND-70918 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline PLO The Phase Locked Oscillator (PLO) is responsible for providing synchronization between the TDSW and another office. In this system, the internal PLO equipped with the MP card is used. The PLO generates a synchronized clock signal according to the source clock signals supplied from the source office within the network, and supplies the generated clock signal to the TDSW. The PLO is supplied...
Page 20
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 7 No. 7 CCIS The PBX can provide No. 7 CCIS via either a digital network or an analog network. Regardless of the relevant network being a digital network or an analog network, CCH (Common Channel Handler) to control the common signaling channel is required. DIGITAL NETWORK When No. 7 CCIS is provided via a digital network, the CCH is connected to the DTI by a fixed path in the TDSW and...