Page 21

CHAPTER 2 ND-45503 (E)
Pag e 12
Revision 2.0
3. CUSTOMER SPECIFICATION SHEETS
This section provides the various sheets for designing the customer specifications of the PBX.
The office data required for customizing the system are programmed with the customer specification.
The installer should complete the following sheets by referring the RESIDENT SYSTEM PROGRAM in the
Command Manual and GENERAL INFORMATION ON CUSTOMIZING DATA in Section 2 of Chapter 3.
3.1 Numbering Plan
Table 2-2  Numbering Plan Data...

Page 22

ND-45503 (E) CHAPTER 2
Page 13
Revision 2.0 3.2 Station Data
Table 2-3  Station Data Table
Note:If space is insufficient, use copies. Department or Section Tenant PROGRAMMING:
CM10,11,12,13,15
STATION 
NUMBERTYPE OF 
TELSERVICE CLASS RESTRICTION CLASS
DID TRUNK 
NUMBERREMARKS
ABDAYNIGHT 

Page 23

CHAPTER 2 ND-45503 (E)
Pag e 14
Revision 2.03.3 Trunk Data
Table 2-4  Trunk Data Table
Note:If space is insufficient, use copies.PROGRAMMING:  CM10, 30, 35, 36
ACCESS 
NUMBERDESTINATIONKIND OF 
TRUNKTYPE OF 
TRUNKNUMBER 
OF LINEDP/PBKIND OF 
SIGNALREMARKS
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW
IC
OG
BW 

Page 24

ND-45503 (E) CHAPTER 2
Page 15
Revision 2.0 3.4 Station Hunting Group Data
Table 2-5  Station Hunting Group Data Table
Note:If space is insufficient, use copies.PROGRAMMING:  CM18
KIND OF STATION
HUNTINGKIND OF STATION
HUNTINGKIND OF STATION
HUNTINGKIND OF STATION
HUNTING
Pilot (        ) Pilot (        ) Pilot (        ) Pilot (        )
Circular Circular Circular Circular
Switch Back Switch Back Switch Back Switch Back
SECRETARY STATION SECRETARY STATION SECRETARY STATION SECRETARY STATION
STATION...

Page 25

CHAPTER 2 ND-45503 (E)
Pag e 16
Revision 2.03.5 Call Pickup Group Data
Table 2-6  Call Pickup Group Data Table
Note:If space is insufficient, use copies.PROGRAMMING:  CM16
STATION NUMBER STATION NUMBER STATION NUMBER STATION NUMBER 

Page 26

ND-45503 (E) CHAPTER 2
Page 17
Revision 2.0 3.6 Speed Calling-System Data
Table 2-7  Speed Calling-System Data Table
Note:If space is insufficient, use copies.PROGRAMMING:  CM71, 72
ABBREVIATED CODE SENDING NUMBER REMARKS 

Page 27

CHAPTER 2 ND-45503 (E)
Pag e 18
Revision 2.0
4. SYSTEM CONFIGURATION
4.1 Port Assignment Table
Table 2-8  Port Assignment Table (1/2) 
 LEN
FILL IN THE STATION NO./TRUNK NO.
LT SLOT NO.
[PIM3]
LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
0195 0199 0203 0207 0211 0215 0219 0223 0227 0231 0235 0239 0243 0247 0251 0255
0194 0198 0202 0206 0210 0214 0218 0222 0226 0230 0234 0238 0242 0246 0250 0254
0193 0197 0201 0205 0209 0213 0217 0221 0225 0229 0233 0237 0241 0245 0249...

Page 28

ND-45503 (E) CHAPTER 2
Page 19
Revision 2.0 Table 2-8  Port Assignment Table (2/2)
 LEN
FILL IN THE STATION NO./TRUNK NO.
LT SLOT NO.
[PIM7]
LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
0451 0455 0459 0463 0467 0471 0475 0479 0483 0487 0491 0495 0499 0503 0507 0511
0450 0454 0458 0462 0466 0470 0474 0478 0482 0486 0490 0494 0498 0502 0506 0510
0449 0453 0457 0461 0465 0469 0473 0477 0481 0485 0489 0493 0497 0501 0505 0509
0448 0452 0456 0460 0464 0468 0472 0476 0480...

Page 29

CHAPTER 2 ND-45503 (E)
Pag e 20
Revision 2.04.2 Bay Face Layout for Module
Figure 2-1  Module Configuration (Floor Standing)
Table 2-9  Quantity Table for Module
FUNCTIONAL NAME MODULE QUANTITY REMARKS
PIM SN1174 PIM-A
BASE BASE (A) ASSEM
RACK PARTS
COVER PARTS
PIM1
PIM3
PIM2
PIM0
BASE
4 PIM (256 ports)
PIM1
PIM2
PIM0
BASE
3 PIM (192 ports)
PIM1
PIM0
BASE
2 PIM (128 ports)
PIM0
BASE
1 PIM (64 ports)
PIM1
PIM3
PIM2
PIM0
BASE
7 PIM (448 ports)
PIM5
PIM6
PIM4
BASE
PIM1
PIM3
PIM2
PIM0
BASE
8 PIM (512 ports)...

Page 30

ND-45503 (E) CHAPTER 2
Page 21
Revision 2.0 4.3 Bay Face Layout for Cards
Figure 2-2  Circuit Card Mounting Slots
Note:For the details of mounting condition, refer to Circuit Card Manual.
BUILT-IN BATTERY
PIM
0-7
LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10/AP0LT11/AP1LT12/AP2LT13/AP3LT14/AP4LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
*1
PWR
*2 *3 *4
LT00-LT15: Line/trunk circuit card mounting slots
AP0-AP8: Application circuit card mounting slots
MP: PN-CP00/PN-CP00-B/PN-CP03 mounting slot
FP: PN-CP01 mounting...
Start reading NEC Neax 2000 Ivs Office Data Programming Manual

Related Manuals for NEC Neax 2000 Ivs Office Data Programming Manual

All NEC manuals