Page 31
CHAPTER 2 ND-45503 (E) Pag e 22 Revision 2.0Table 2-10 Quantity Table for Line/Trunk Circuit Cards FUNCTIONAL NAMECARD NAMEPIM0 PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7 TOTAL LC PN-4LC AU C P N - AU C DLC PN-4DLC/ PN-2DLC COT PN-4COT ODT PN-2ODT PBR PN-8RST DK PN-DK00 DAT PN-2 DAT CFT PN-CFT DPC PN-2DPC TNT PN-TNT DIT PN-4DIT AMP PN-2AMP ILC PN-2ILC M03 PN-M03 Table 2-11 Quantity Table for Control Circuit Cards FUNCTIONAL NAMECARD NAMEPIM0 PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7 TOTAL BS00 PN-BS00 BS01 PN-BS01...
Page 32
ND-45503 (E) CHAPTER 2 Addendum-001 Page 23 JULY, 1998 Revision 2.1 Table 2-12 Quantity Table for Application Circuit Cards FUNCTIONAL NAMECARD NAMEPIM0 PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7 TOTAL AP00 PN-AP00 AP01 PN-AP01 BRI PN-BRTA BRI PN-2BRTC CCH PN-SC00 CIR PN-4RSTC DBM PN-AP00 DCH PN-SC01 DTI PN-24DTA DTI PN-30DTC DTI PN-30DTC-A ETHER PN-CC00 ETHER PN-CC01 EXTMEM PN-ME00 ICH PN-SC02/SC03 MFR PN-4RST PLO PN-CK00
Page 34
ND-45503 (E) CHAPTER 3 Page 25 Revision 2.0 CHAPTER 3 DATA PROGRAMMING SHEETS 1. GENERAL This chapter provides the System Data Sheets for programming the Customer Specifications in Chapter 2. For the programming method and the detailed information on the commands, refer to the Command Manual. In the Programming sheets, the meanings of markings are as follows: : Initial Data With the system data clear command (CM00, CM01), the data with this marking is automatically as- signed for each command. In the...
Page 35
CHAPTER 3 ND-45503 (E) Pag e 26 Revision 2.0SLOT NUMBER DATA 04 05 06 07 08 09 10 11 12 13 14 15 MATINITIALCM05 EXEDEST COMMAND 05:++ 05++ + SLOT NUMBERDESETTING DATA (2 digits) (2 digits) +
Page 36
ND-45503 (E) CHAPTER 3 Page 27 Revision 2.0 • YY = 04 CM06 YY = 04 MFR TRK No. SLOT No. CIRCUIT No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15INITIAL EXEDESTCOMMAND 06:++ 0604++ + MFR TRK No.DE (2 digits) +SLOT No. + CIRCUIT No. (3 digits)
Page 37
CHAPTER 3 ND-45503 (E) Pag e 28 Revision 2.0 • YY = 07 • YY = 08 CM06 YY = 07 CCH No. SLOT No. 0 1 2 3 CM06 YY = 08 DCH No. SLOT No. 0 1 2 3 4INITIAL ST + + ++ 0607DE +DE COMMAND 06:CCH No. (1 digit)SLOT No. (2 digits)+EXE INITIAL ST ++ ++ 0608DE +DE COMMAND 06:DCH No. (1 digit)SLOT No. (2 digits)+EXE
Page 38
ND-45503 (E) CHAPTER 3 Page 29 Revision 2.0 • YY = 09 CM06 YY = 09 ICH No. SLOT No. 00 01 02 03 04 05 06 07 08 09 10 11INITIAL ST ++ ++ 0609DE +DE COMMAND 06:ICH No. (2 digits)SLOT No. (2 digits)+EXE
Page 39
CHAPTER 3 ND-45503 (E) Pag e 30 Revision 2.0Note:If space is insufficient, use copies. CM06 YY=10 SLOT No. + D CHANNEL BLOCK No.LENSLOT No. + D CHANNEL BLOCK No.LEN LEN (4 digits)ST +++0610DE COMMAND 06:+EXE SLOT No. + D ch BLOCK No. (4 digits)+ +DE
Page 40
ND-45503 (E) CHAPTER 3 Pag e 31 Revision 2.0 Note:If space is insufficient, use copies. CM07 YY=01 SLOT No. CH No. TRK No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23INITIALCM07 YY=01 SLOT No. CH No. TRK No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23INITIAL EXEDESTCOMMAND 07:++ 07YY++ +DE +SLOT No. + CH No. (4 digits)TRUNK No. (4 digits)