Page 31

CHAPTER 2 ND-45503 (E)
Pag e 22
Revision 2.0Table 2-10  Quantity Table for Line/Trunk Circuit Cards
FUNCTIONAL 
NAMECARD
NAMEPIM0 PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7 TOTAL
LC PN-4LC
AU C P N - AU C
DLC PN-4DLC/
PN-2DLC
COT PN-4COT
ODT PN-2ODT
PBR PN-8RST
DK PN-DK00
DAT PN-2 DAT
CFT PN-CFT
DPC PN-2DPC
TNT PN-TNT
DIT PN-4DIT
AMP PN-2AMP
ILC PN-2ILC
M03 PN-M03
Table 2-11  Quantity Table for Control Circuit Cards
FUNCTIONAL 
NAMECARD
NAMEPIM0 PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7 TOTAL
BS00 PN-BS00
BS01 PN-BS01...

Page 32

ND-45503 (E) CHAPTER 2
Addendum-001 Page 23
JULY, 1998 Revision 2.1 Table 2-12  Quantity Table for Application Circuit Cards
FUNCTIONAL 
NAMECARD
NAMEPIM0 PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7 TOTAL
AP00 PN-AP00
AP01 PN-AP01
BRI PN-BRTA
BRI PN-2BRTC
CCH PN-SC00
CIR PN-4RSTC
DBM PN-AP00
DCH PN-SC01
DTI PN-24DTA
DTI PN-30DTC
DTI PN-30DTC-A
ETHER PN-CC00
ETHER PN-CC01
EXTMEM PN-ME00
ICH PN-SC02/SC03
MFR PN-4RST
PLO PN-CK00 

Page 33

CHAPTER 2 ND-45503 (E)
Pag e 24
Revision 2.0
This page is for your notes. 

Page 34

ND-45503 (E) CHAPTER 3
Page 25
Revision 2.0
CHAPTER 3 DATA PROGRAMMING SHEETS
1. GENERAL
This chapter provides the System Data Sheets for programming the Customer Specifications in Chapter 2. For
the programming method and the detailed information on the commands, refer to the Command Manual.
In the Programming sheets, the meanings of markings are as follows:
 : Initial Data
With the system data clear command (CM00, CM01), the data with this marking is automatically as-
signed for each command.
In the...

Page 35

CHAPTER 3 ND-45503 (E)
Pag e 26
Revision 2.0SLOT NUMBER DATA
04
05
06
07
08
09
10
11
12
13
14
15
MATINITIALCM05
EXEDEST COMMAND 05:++
05++ + SLOT NUMBERDESETTING DATA
(2 digits) (2 digits) + 

Page 36

ND-45503 (E) CHAPTER 3
Page 27
Revision 2.0
• YY = 04
CM06 YY = 04
MFR TRK No. SLOT No. CIRCUIT No.
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15INITIAL
EXEDESTCOMMAND 06:++
0604++ + MFR TRK No.DE
(2 digits) +SLOT No. + CIRCUIT No.
(3 digits) 

Page 37

CHAPTER 3 ND-45503 (E)
Pag e 28
Revision 2.0
• YY = 07
• YY = 08
CM06 YY = 07
CCH No. SLOT No.
0
1
2
3
CM06 YY = 08
DCH No. SLOT No.
0
1
2
3
4INITIAL
ST + + ++ 0607DE +DE
COMMAND 06:CCH No.
(1 digit)SLOT No.
(2 digits)+EXE
INITIAL
ST
++ ++ 0608DE
+DE
COMMAND 06:DCH No.
(1 digit)SLOT No.
(2 digits)+EXE 

Page 38

ND-45503 (E) CHAPTER 3
Page 29
Revision 2.0
• YY = 09
CM06 YY = 09
ICH No. SLOT No.
00
01
02
03
04
05
06
07
08
09
10
11INITIAL
ST
++ ++ 0609DE
+DE
COMMAND 06:ICH No.
(2 digits)SLOT No.
(2 digits)+EXE 

Page 39

CHAPTER 3 ND-45503 (E)
Pag e 30
Revision 2.0Note:If space is insufficient, use copies.
CM06 YY=10
SLOT No. + D CHANNEL
BLOCK No.LENSLOT No. + D CHANNEL
BLOCK No.LEN
LEN
(4 digits)ST
+++0610DE
COMMAND 06:+EXE SLOT No. +
D ch BLOCK No.
(4 digits)+ +DE 

Page 40

ND-45503 (E) CHAPTER 3
Pag e 31
Revision 2.0 Note:If space is insufficient, use copies.
CM07 YY=01
SLOT No. CH No. TRK No.
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23INITIALCM07 YY=01
SLOT No. CH No. TRK No.
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23INITIAL
EXEDESTCOMMAND 07:++
07YY++ +DE +SLOT No. + CH No.
(4 digits)TRUNK No.
(4 digits) 