Home > NEC > Communications System > NEC Neax 2000 Ivs Office Data Programming Manual

NEC Neax 2000 Ivs Office Data Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Office Data Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 2 ND-45503 (E)
    Pag e 12
    Revision 2.0
    3. CUSTOMER SPECIFICATION SHEETS
    This section provides the various sheets for designing the customer specifications of the PBX.
    The office data required for customizing the system are programmed with the customer specification.
    The installer should complete the following sheets by referring the RESIDENT SYSTEM PROGRAM in the
    Command Manual and GENERAL INFORMATION ON CUSTOMIZING DATA in Section 2 of Chapter 3.
    3.1 Numbering Plan
    Table 2-2  Numbering Plan Data Table
    Note:If space is insufficient, use copies. Numbering Plan Group PROGRAMMING:  CM20, 21
    ACCESS CODE FUNCTIONS REMARKS 
    						
    							ND-45503 (E) CHAPTER 2
    Page 13
    Revision 2.0 3.2 Station Data
    Table 2-3  Station Data Table
    Note:If space is insufficient, use copies. Department or Section Tenant PROGRAMMING:
    CM10,11,12,13,15
    STATION 
    NUMBERTYPE OF 
    TELSERVICE CLASS RESTRICTION CLASS
    DID TRUNK 
    NUMBERREMARKS
    ABDAYNIGHT 
    						
    							CHAPTER 2 ND-45503 (E)
    Pag e 14
    Revision 2.03.3 Trunk Data
    Table 2-4  Trunk Data Table
    Note:If space is insufficient, use copies.PROGRAMMING:  CM10, 30, 35, 36
    ACCESS 
    NUMBERDESTINATIONKIND OF 
    TRUNKTYPE OF 
    TRUNKNUMBER 
    OF LINEDP/PBKIND OF 
    SIGNALREMARKS
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW 
    						
    							ND-45503 (E) CHAPTER 2
    Page 15
    Revision 2.0 3.4 Station Hunting Group Data
    Table 2-5  Station Hunting Group Data Table
    Note:If space is insufficient, use copies.PROGRAMMING:  CM18
    KIND OF STATION
    HUNTINGKIND OF STATION
    HUNTINGKIND OF STATION
    HUNTINGKIND OF STATION
    HUNTING
    Pilot (        ) Pilot (        ) Pilot (        ) Pilot (        )
    Circular Circular Circular Circular
    Switch Back Switch Back Switch Back Switch Back
    SECRETARY STATION SECRETARY STATION SECRETARY STATION SECRETARY STATION
    STATION NUMBER STATION NUMBER STATION NUMBER STATION NUMBER 
    						
    							CHAPTER 2 ND-45503 (E)
    Pag e 16
    Revision 2.03.5 Call Pickup Group Data
    Table 2-6  Call Pickup Group Data Table
    Note:If space is insufficient, use copies.PROGRAMMING:  CM16
    STATION NUMBER STATION NUMBER STATION NUMBER STATION NUMBER 
    						
    							ND-45503 (E) CHAPTER 2
    Page 17
    Revision 2.0 3.6 Speed Calling-System Data
    Table 2-7  Speed Calling-System Data Table
    Note:If space is insufficient, use copies.PROGRAMMING:  CM71, 72
    ABBREVIATED CODE SENDING NUMBER REMARKS 
    						
    							CHAPTER 2 ND-45503 (E)
    Pag e 18
    Revision 2.0
    4. SYSTEM CONFIGURATION
    4.1 Port Assignment Table
    Table 2-8  Port Assignment Table (1/2) 
     LEN
    FILL IN THE STATION NO./TRUNK NO.
    LT SLOT NO.
    [PIM3]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0195 0199 0203 0207 0211 0215 0219 0223 0227 0231 0235 0239 0243 0247 0251 0255
    0194 0198 0202 0206 0210 0214 0218 0222 0226 0230 0234 0238 0242 0246 0250 0254
    0193 0197 0201 0205 0209 0213 0217 0221 0225 0229 0233 0237 0241 0245 0249 0253
    0192 0196 0200 0204 0208 0212 0216 0220 0224 0228 0232 0236 0240 0244 0248 0252
    [PIM2]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0131 0135 0139 0243 0147 0151 0155 0159 0163 0167 0171 0175 0179 0183 0187 0191
    0130 0134 0138 0142 0146 0150 0154 0158 0162 0166 0170 0174 0178 0182 0186 0190
    0129 0133 0137 0141 0145 0149 0153 0157 0161 0165 0169 0173 0177 0181 0185 0189
    0128 0132 0136 0140 0144 0148 0152 0156 0160 0164 0168 0172 0176 0180 0184 0188
    [PIM1]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0067 0071 0075 0079 0083 0087 0091 0095 0099 0103 0107 0111 0115 0119 0123 0127
    0066 0070 0074 0078 0082 0086 0090 0094 0098 0102 0106 0110 0114 0118 0122 0126
    0065 0069 0073 0077 0081 0085 0089 0093 0097 0101 0105 0109 0113 0117 0121 0125
    0064 0068 0072 0076 0080 0084 0088 0092 0096 0100 0104 0108 0112 0116 0120 0124
    [PIM0]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0003 0007 0011 0015 0019 0023 0027 0031 0035 0039 0043 0047 0051 0055 0059 0063
    0002 0006 0010 0014 0018 0022 0026 0030 0034 0038 0042 0046 0050 0054 0058 0062
    0001 0005 0009 0013 0017 0021 0025 0029 0033 0037 0041 0045 0049 0053 0057 0061
    0000 0004 0008 0012 0016 0020 0024 0028 0032 0036 0040 0044 0048 0052 0056 0060 
    						
    							ND-45503 (E) CHAPTER 2
    Page 19
    Revision 2.0 Table 2-8  Port Assignment Table (2/2)
     LEN
    FILL IN THE STATION NO./TRUNK NO.
    LT SLOT NO.
    [PIM7]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0451 0455 0459 0463 0467 0471 0475 0479 0483 0487 0491 0495 0499 0503 0507 0511
    0450 0454 0458 0462 0466 0470 0474 0478 0482 0486 0490 0494 0498 0502 0506 0510
    0449 0453 0457 0461 0465 0469 0473 0477 0481 0485 0489 0493 0497 0501 0505 0509
    0448 0452 0456 0460 0464 0468 0472 0476 0480 0484 0488 0492 0496 0500 0504 0508
    [PIM6]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0387 0391 0395 0399 0403 0407 0411 0415 0419 0423 0427 0431 0435 0439 0443 0447
    0386 0390 0394 0398 0402 0406 0410 0414 0418 0422 0426 0430 0434 0438 0442 0446
    0385 0389 0393 0397 0401 0405 0409 0413 0417 0421 0425 0429 0433 0437 0441 0445
    0384 0388 0392 0396 0400 0404 0408 0412 0416 0420 0424 0428 0432 0436 0440 0444
    [PIM5]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0323 0327 0331 0335 0339 0343 0347 0351 0355 0359 0363 0367 0371 0375 0379 0383
    0322 0326 0330 0334 0338 0342 0346 0350 0354 0358 0362 0366 0370 0374 0378 0382
    0321 0325 0329 0333 0337 0341 0345 0349 0353 0357 0361 0365 0369 0373 0377 0381
    0320 0324 0328 0332 0336 0340 0344 0348 0352 0356 0360 0364 0368 0372 0376 0380
    [PIM4]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15
    0259 0263 0267 0271 0275 0279 0283 0287 0291 0295 0299 0303 0307 0311 0315 0319
    0258 0262 0266 0270 0274 0278 0282 0286 0290 0294 0298 0302 0306 0310 0314 0318
    0257 0261 0265 0269 0273 0277 0281 0285 0289 0293 0297 0301 0305 0309 0313 0317
    0256 0260 0264 0268 0272 0276 0280 0284 0288 0292 0296 0300 0304 0308 0312 0316 
    						
    							CHAPTER 2 ND-45503 (E)
    Pag e 20
    Revision 2.04.2 Bay Face Layout for Module
    Figure 2-1  Module Configuration (Floor Standing)
    Table 2-9  Quantity Table for Module
    FUNCTIONAL NAME MODULE QUANTITY REMARKS
    PIM SN1174 PIM-A
    BASE BASE (A) ASSEM
    RACK PARTS
    COVER PARTS
    PIM1
    PIM3
    PIM2
    PIM0
    BASE
    4 PIM (256 ports)
    PIM1
    PIM2
    PIM0
    BASE
    3 PIM (192 ports)
    PIM1
    PIM0
    BASE
    2 PIM (128 ports)
    PIM0
    BASE
    1 PIM (64 ports)
    PIM1
    PIM3
    PIM2
    PIM0
    BASE
    7 PIM (448 ports)
    PIM5
    PIM6
    PIM4
    BASE
    PIM1
    PIM3
    PIM2
    PIM0
    BASE
    8 PIM (512 ports)
    PIM5
    PIM7
    PIM6
    PIM4
    BASE
    PIM1
    PIM3
    PIM2
    PIM0
    BASE
    5 PIM (320 ports)
    PIM4
    BASE
    PIM1
    PIM3
    PIM2
    PIM0
    BASE
    6 PIM (384 ports)
    PIM5
    PIM4
    BASE 
    						
    							ND-45503 (E) CHAPTER 2
    Page 21
    Revision 2.0 4.3 Bay Face Layout for Cards
    Figure 2-2  Circuit Card Mounting Slots
    Note:For the details of mounting condition, refer to Circuit Card Manual.
    BUILT-IN BATTERY
    PIM
    0-7
    LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10/AP0LT11/AP1LT12/AP2LT13/AP3LT14/AP4LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    *1
    PWR
    *2 *3 *4
    LT00-LT15: Line/trunk circuit card mounting slots
    AP0-AP8: Application circuit card mounting slots
    MP: PN-CP00/PN-CP00-B/PN-CP03 mounting slot
    FP: PN-CP01 mounting slots
    BUS: PN-BS00/PN-BS01 mounting slot
    PWR: PZ-PW86 mounting slot
    *1Either line/trunk circuit cards or application circuit cards can be mounted in these slots.
    *2PN-CP01 or an application circuit card is to be mounted in this slot according to the system
    configuration.
    *3PN-CP00
    /PN-CP03, PN-CP01 or an application circuit card is to be mounted in this slot
    according to the system configuration.
    *4PN-BS00, PN-BS01 or an application circuit card is to be mounted in this slot according to
    the system configuration. 
    						