CHAPTER 1 ND-4 5503 ( E) D ATA P R O G RAM MIN G M ETH OD CIR CU IT C AR D MANU AL IN STA LLA TI ON PR O CEDURE M AN U AL D ESCRI PTIO N
CHAPTER 1 ND-45503 (E) Pag e 4 Revision 2.0 This page is for your notes.
ND-45503 (E) CHAPTER 2 Pag e 5 Revision 2.0 CHAPTER 2 CUSTOMIZING DATA 1. GENERAL This chapter explains the general information for customizing data and the various tables for customer specifications such as numbering plan, station data and trunk data, etc., and sheets for designing the system layout such as Bay Face Layout. 2. GENERAL INFORMATION ON CUSTOMIZING DATA This section provides the information for customizing data in the Office Data Programming Manual. 2.1 Numbering Plan This table specifies the service feature access codes, trunk access code, station numbers and other special access codes. The service feature access codes and trunk access codes are given to each service feature and each trunk routes, respectively, with a maximum three-digit code. The station numbers are specified by a maximum of four digits. For the numbering plan of the system the following conditions should be considered. (1) The same first digit code cannot be assigned to the other features within the Numbering Plan Group programmed. (This condition is not applicable to the system providing the Single Digit Timing Start Access.) (2) The feature access codes should be two or three digits because plural access codes for each feature are required. (3) There are four types of station numbering (1 digit – 4 digits), and any combination of these types is available in one system. (4) The same station number cannot be assigned, even if the tenant service is applied. 2.2 Station Data In this table, the following data are required. • Station Number Station numbers (up to four digits), specified in the Numbering Plan Table, are assigned. For the D term sta- tion, specify the My Line Number.
CHAPTER 2 ND-45503 (E) Pag e 6 Revision 2.0 • Type of Telephone The type of station telephone set is specified as shown below. TYPE OF TEL DESCRIPTION DP ........................... Dial Pulse Telephone set PB ........................... DTMF Telephone set D term....................... Dterm set • SERVICE CLASS-A/B/C Specify the service class (1-15) programmed in the Service Restriction Data Table. • RESTRICTION CLASS-DAY/NIGHT Specify the Trunk Restriction Class as shown below. 1: Unrestricted 2: Non-Restricted-1 3: Non-Restricted-2 4: Semi-Restricted 1 5: Semi-Restricted 2 6: Restricted 1 7: Restricted 2 8: Fully-Restricted • DIT TRUNK NUMBER In the case of the DIT (Direct-In Termination) station, specify the trunk number connected. 2.3 Trunk Data In this table, the following data are required: • ACCESS NUMBER Specify the access code for the trunks. • DESTINATION Specify the distant office such as Central Office (Public Exchange), Tie Line, etc. • NUMBER OF LINE Specify the number of trunks to be provided with each route (IC-Incoming, OG-Outgoing, BW-Bothway).
ND-45503 (E) CHAPTER 2 Pag e 7 Revision 2.0 • DP/PB Specify the type of address signal from/to distant office, as shown below. TYPE OF TEL DESCRIPTION DP ......................... Dial Pulse PB ......................... DTMF Signal • KIND OF SIGNAL Specify the kind of signaling system such as Ring Down, Loop, E & M etc. at the line. 2.4 Station Hunting Group Data This data table requires the following data: • KIND OF STATION HUNTING Specify the kind of the Station Hunting System (Pilot/Circular/Switch Back). In the case of the Pilot System, specify the Pilot Station Number. • S E C R E TA RY S TAT I O N Specify the Secretary Station Number, if provided. • STATION NUMBER Specify the station numbers to be assigned to the station hunting group with the following conditions. (1) Up to 60 stations can be assigned per Station Hunting Group. (2) There is no limitation to the number of Station Hunting Groups. The same one station cannot be assigned to multiple Hunting Groups. 2.5 Call Pickup Group Data The station number to be assigned to the Call Pickup Group with the following conditions. (1) Up to 60 station can be assigned per Call Pickup Group. (2) There is no limitation to the number of Call Pickup Groups. (3) The same one station cannot be assigned to multiple Call Pickup Groups. 2.6 Speed Calling-System Data This data table requires the abbreviated code and the stored number to be sent out. A maximum stored num- ber of 28 digits can be assigned.
CHAPTER 2 ND-4 5503 ( E) LE V EL 3 LT 00 2 01 — F XXX D 00 3
ND-45503 (E) CHAPTER 2 Pag e 9 Revision 2.0 PN-AUC PN-2LDT PN-2ODTThe trunk number must be assigned to the 1st LEN (LEVEL 0) and/or 2nd LEN (LEVEL 1) of each LT slot. PN-2DAT • The card number must be assigned to the 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot. • The card numbers are allocated to each PIM as shown below. Card Number Accommodated in EB000-EB031 PIM0/PIM1 EB032-EB063 PIM2/PIM3 EB064-EB095 PIM4/PIM5 EB096-EB127 PIM6/PIM7 PN-8RST • The card number must be assigned to the 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot. • The card numbers are allocated to each PIM as shown below. Card Number Accommodated in E200-E203 PIM0/PIM1 E204-E207 PIM2/PIM3 E208-E211 PIM4/PIM5 E212-E215 PIM6/PIM7 Table 2-1 Port Assignment Method (Continued) CARD TO BE ASSIGNEDPORT ASSIGNMENT TABLE REMARKS — 0003 — 0002 D001 0001 D000 0000LT 0 0 LEVEL 3 LEVEL 2 LEVEL 1 LEVEL 0Not to be assigned Tr u n k N o . (D000-D255) LEVEL 3 LT00 — 0003 EB001 0002 — 0001 EB000 0000 LEVEL 2 LEVEL 1 LEVEL 0Not to beCard No. assigned (EB000-EB127) LEVEL 3 LT00 — 0003 E201 0002 — 0001 E200 0000 LEVEL 2 LEVEL 1 LEVEL 0Not to beCard No. assigned (E200-E215)
CHAPTER 2 ND-45503 (E) Pag e 10 Revision 2.0PN-DK00 • The card number must be assigned to the 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot. • The card numbers of External Equipment Interface are allocated to each PIM as shown below. Card Number Accommodated in E800-E807 PIM0/PIM1 E808-E815 PIM2/PIM3 E816-E823 PIM4/PIM5 E824-E831 PIM6/PIM7 • The card numbers of External Key Interface are allocated to each PIM as shown below. Card Number Accommodated in E900-E915 PIM0/PIM1 E916-E931 PIM2/PIM3 E932-E947 PIM4/PIM5 E948-E963 PIM6/PIM7 PN-CFT The card number must be assigned to the 1st LEN (LEVEL 0) of each LT slot. PN-2AMP • The card number must be assigned to the 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot. • The card numbers are allocated to each PIM as shown below. Card Number Accommodated in C100-C115 PIM0/PIM1 C116-C131 PIM2/PIM3 C132-C147 PIM4/PIM5 C148-C163 PIM6/PIM7 Table 2-1 Port Assignment Method (Continued) CARD TO BE ASSIGNEDPORT ASSIGNMENT TABLE REMARKS LEVEL 3 LT00 — 0003 E801 0002 — 0001 E800 0000 LEVEL 2 LEVEL 1 LEVEL 0Not to beCard No. assigned (E800-E831) LEVEL 3 LT00 — 0003 E901 0002 — 0001 E900 0000 LEVEL 2 LEVEL 1 LEVEL 0Not to beCard No. assigned (E900-E963) LEVEL 3 LEVEL 2 LEVEL 1 LEVEL 0Not to be Card No. assigned (ED00-ED03) LT00 — 0003 — 0002 — 0001 ED00 0000 LEVEL 3 LEVEL 2 LEVEL 1 LEVEL 0Not to be Card No. assigned (C100-C163) LT00 — 0003 C101 0002 — 0001 C100 0000
ND-45503 (E) CHAPTER 2 Page 11 Revision 2.0 PN-2ILC • The ISDN circuit station number must be assigned to the 1st LEN (LEVEL 0) and/or 2nd LEN (LEVEL 1) of each LT slot. Table 2-1 Port Assignment Method (Continued) CARD TO BE ASSIGNEDPORT ASSIGNMENT TABLE REMARKS — 0003 — 0002 201 0001 200 0000LT 0 0 LEVEL 3 LEVEL 2 LEVEL 1 LEVEL 0Not to be assigned ISDN Circuit Station No.