    							CHAPTER 3 ND-45503 (E)
    Page 108-2 Addendum-002
    Revision 2.2 JANUARY, 1999
    This page is for your notes. 
    						
    							ND-45503 (E) CHAPTER 3
    Pag e 1 09
    Revision 2.0 CM71 CM71
    KIND OF
    CALLING
    PARTYSETTING DATAKIND OF
    CALLING
    PA R T YSETTING DATA
    1ST MEMORY SLOT No.
    (000-299)SLOT No.
    (001-300)1ST MEMORY SLOT No.
    (000-299)SLOT No.
    (001-300)
    00 34
    01 35
    02 36
    03 37
    04 38
    05 39
    06 40
    07 41
    08 42
    09 43
    10 44
    11 45
    12 46
    13 47
    14 48
    15 49
    16 50
    17 51
    18 52
    19 53
    20 54
    21 55
    22 56
    23 57
    24 58
    25 59
    26 60
    27 61
    28 62
    29 63
    30 64
    31 65
    32 66
    33 68
    MATMAT
    STEXE ++ ++
    71DE
    SETTING DATA KIND OF CALLING PARTY+DE
    COMMAND 71:+
    (6 digits) (2 digits) 
    						
    							CHAPTER 3 ND-45503 (E)
    Pag e 1 10
    Revision 2.0Note:If space is insufficient, use copies.
    CM72
    MEMORY 
    SLOT 
    NUMBERSTORED NUMBER
    TENANT 
    NUMBERABBREVIATED 
    CODE
    ACCESS 
    CODESEPARATE 
    MARKCALLED PARTY NUMBER (MAX. 26 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    STEXE ++ ++ 72DE
    STORED NUMBER MEMORY SLOT +DE
    COMMAND 72:+
    NUMBER
    (3 digits)(Max. 28 digits) 
    						
    							ND-45503 (E) CHAPTER 3
    Pag e 1 11
    Revision 2.0 Note:If space is insufficient, use copies.
    CM73
    STATION
    NUMBERSETTING DATA
    1000 SLOTS
    MEMORY
    BLOCK
    (0-4, 8-F)10 SLOTS
    MEMORY BLOCK
    IN THE TOP
    (00-99)POSSIBLE/NOT
    POSSIBLE OF
    REGISTRATION
    (0/1)NUMBER OF 10
    SLOTS MEMORY
    BLOCK
    (01-10)
    SETTING DATA
    (6 digits)ST + + +DE+DE
    COMMAND 73:+EXE STATION NUMBER
    (1-4 digits) 73+ 
    						
    							CHAPTER 3 ND-45503 (E)
    Pag e 1 12
    Revision 2.0Note:If space is insufficient, use copies.
    CM74
    MEMORY SLOT NUMBER STORED NUMBER
    1000 SLOTS
    MEMORY
    BLOCK
    (0-4, 8-F)10 SLOTS
    MEMORY
    BLOCK
    (00-99)SLOTS
    (0-9)ACCESS
    CODE
    (MAX.
    2 DIGITS)SEPARATOR
    MARKCALLED PARTY’S NUMBER
     (MAX. 26 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    MEMORY SLOT 
    NUMBER
    (4 digits)STORED NUMBER
    (MAX. 26 digits)ST + + +DE+DE
    COMMAND 74:+EXE
    74+ 
    						
    							ND-45503 (E) CHAPTER 3
    Pag e 1 13
    Revision 2.0 Note:If space is insufficient, use copies.
    CM76 CM76
    Y (0/1) RECEIVED DIGITS DATA Y (0/1) RECEIVED DIGITS DATA
    CM76
    RECEIVED DIGITS Y = 4 Y = 5 Y = 6
    NONE 1 1
    STEXE ++ ++ 76YDE
    SETTING DATA RECEIVED DIGITS +DE
    COMMAND 76:+
    (1-4 digits) (1-4 digits) 
    						
    							CHAPTER 3 ND-45503 (E)
    Pag e 1 14
    Revision 2.0Note:If space is insufficient, use copies.
    CM77 CM77
    Y
    0
    3STATION/TRUNK 
    NAME No.DATA Y
    0
    3STATION/TRUNK 
    NAME No.DATA
    CHARACTER CODE CHARACTER CODE
    MATMAT
    ~
    ~
    STEXE ++ ++ 77YDE SETTING DATASTATION No. +DE
    COMMAND 77:+ TRUNK NAME No. /
    (1-4 digits) (2 digits) (1-16 digits) 
    						
    							ND-45503 (E) CHAPTER 3
    Pag e 1 15
    Revision 2.0 Note:If space is insufficient, use copies.
    CM78
    1 S T  D ATA 2 N D  D ATA
    TENANT
    NUMBER
    (2 DIGITS)BLOCK
    NUMBER
    (1 DIGIT)WHEN
    DESTINATION
    IS A STATIONWHEN DESTINATION IS AN OUTSIDE PARTY
    STATION NUMBER
    (1–4 DIGITS)TRUNK ACCESS
    CODE (1–3 DIGITS)SEPARATE
    MARKCALLED NUMBER (MAX. 26
    DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    EXEDESTCOMMAND 78:++78 + + + +1ST DATADE2ND DATA
    (1-29 digits) (3 digits) 
    						
    							CHAPTER 3 ND-45503 (E)
    Pag e 1 16
    Revision 2.0
    DATA 0: Restricted
    1: Restricted (Same as Data “0”)
    3: Allowed
    :  Initial Data
    CM81
    TRUNK RESTRICTION CLASSYY
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
    0100
    02 03 04 05 06 07 08 09 10 11 12 13 14 15
    1 RCA 3033300033333030
    2 RCB 3033000 033000030
    3 RCC 3030000030000030
    4 RCD 3000000000000030
    5 RCE 3000000000000030
    1 RCA30
    2 RCB30
    3 RCC30
    4 RCD30
    5 RCE30
    STEXE ++ ++ 81YYDE
    SETTING DATA TRUNK RESTRICTION +DE
    COMMAND 81:+
    CLASS
    (1 digit)(1 digit) 
    						
    							ND-45503 (E) CHAPTER 3
    Pag e 1 17
    Revision 2.0 CM85 CM85
    YAREA/OFFICE CODE 
    (MAX. 8 DIGITS)MAX. No. OF 
    SENDING DIGITSYAREA/OFFICE CODE 
    (MAX. 8 DIGITS)MAX. No. OF 
    SENDING DIGITS
    :  Initial Data
    CM88
    BLOCK 
    NUMBERY=0(1-7 DIG-
    ITS)Y=1(0/3 ) Y=2(1-3 )
    MATMAT
    STEXE ++ ++ 85YDEMAX. No. OF
    OFFICE CODE+DE
    COMMAND 85:+
    (1-8 digits)SENDING DIGITS
    (2 digits)
    STEXE ++ ++ 88YDESETTING DATA
    BLOCK NUMBER+DE
    COMMAND 88:+
    (1-7 digits)
    (2 digits) 
    						
    All NEC manuals Comments (0)