NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-009 TROUBLESHOOTING OF EC H221 MUX UNIT GENERAL: Sectionalization of failure is conducted by the front lamp (LED) indication of EC H221 MUX unit. APPARATUS: None STEP PROCEDURE REFERENCE NO. Note: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-004 . 1 Is FUN ER (RC10) or MEM ER (RC 9)LED lit? If YES , the EC H221 MUX unit is faulty. Replace it. If NO , go to Step 2 .TCP-017 2 Is REC (RC16) LED...
Page 672
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-009 MCU 5000A Multipoint Control Unit TROUBLESHOOTING OF EC H221 MUX UNIT STEP PROCEDURE REFERENCE NO. 8 Set the MUX strap terminal of this unit to ON. Note: By doing this, it becomes possible that the H221 synchronizing signal is substituted and Low Speed Data, video and audio signals are looped back to the line side. 9 Verify that low speed data, video, and audio signals of local station can be received at each conference room by requesting the remote...
Page 673
NECA 340-4 14- 50 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit TCP-010 TR OUBLESHO OTING OF PG/SIO UNIT
Page 674
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-010 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 675
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-011 TROUBLESHOOTING OF V SW/LSD IF UNIT GENERAL: Sectionalization of failure is performed by the LED indication of V SW/ LSD IF unit. APPARATUS: None STEP PROCEDURE REFERENCE NO. Note 1: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-005 . Note 2: These do not indicate failure conditions directly but may be an aid to failure sectionalization. Note 3: When a failure has happened to the visual...
Page 676
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-011 MCU 5000A Multipoint Control Unit TROUBLESHOOTING OF V SW/LSD IF UNIT STEP PROCEDURE REFERENCE NO. 7 Are broadcast sending station LEDs (TX1 to 8) lit? If YES, go to Step 11. If NO, go to Step 8. 8 Request the system operator to send the voice signal from the conference room (send his own voice). 9 Are broadcast sending station LEDs (TX 1to 8) lit? If YES, go to Step 11. If NO, go to Step 12. 10 This unit operates normally. Then, go to Step 12....
Page 677
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-012 TROUBLESHOOTING OF A CODEC UNIT GENERAL: Sectionalization of failure is performed by the LED indication of A CODEC unit. APPARATUS: None STEP PROCEDURE REFERENCE NO. Note: 1: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-006 . Note 2: These do not indicate failure conditions directly but may be an aid to failure sectionalization. Note 3: When a failure has happened to the audio system,...
Page 678
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-012 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 679
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-013 TROUBLESHOOTING OF A SUM UNIT GENERAL: Sectionalization of failure is performed on the A SUM unit. APPARATUS: Level Meter or Speaker with amplifier Figure 1: Monitoring of Audio Signal STEP PROCEDURE REFERENCE NO. Note 1: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-007 . Note 2: These do not indicate failure conditions directly but may be an aid to failure sectionalization. Note 3: This...
Page 680
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-013 MCU 5000A Multipoint Control Unit This page is for your notes.