NEC Mcu 5000a Multipoint Control Unit Equipment Manual
Here you can view all the pages of manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 661
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-004 EXECUTION OF MCU 5000A LOOP TEST GENERAL: Perform a MCU 5000A loopback test at an arbitrary loop point using TLOP command, referring to NECA 340-414-300 . APPARATUS: MCU console STEP PROCEDURE REFERENCE NO. 1 Has the MCU console been started up? If YES , go to Step 3 . If NO , go to Step 2 . 2 Start the MCU console up and put it into communication state.TCP-016 3 Before the execution of loop test, the loopback...
Page 662
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-004 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 663
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-005 TROUBLESHOOTING OF M CONT UNIT GENERAL: Sectionalization of the failure is performed by the front lamp (LED) indication of M CONT unit. APPARATUS: None STEP PROCEDURE REFERENCE NO. Note: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-009 . 1 Verify the LED condition. If ST1 to ST6 are indicated steadily, go to Step 2 . If ST7 is lit, go to Step 3 . If ST8 is lit, go to Step 4 . 2 When ST1...
Page 664
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-005 MCU 5000A Multipoint Control Unit TROUBLESHOOTING OF M CONT UNIT STEP PROCEDURE REFERENCE NO. 7 Verify the state of Memory Card using RMCS command. If response is displayed with LOW BATTERY VOLTAGE , replace the battery with a new one. If response is displayed with ERR81 , replace the Memory Card with a new one.TCP-019 8 End of procedure.
Page 665
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-006 TROUBLESHOOTING OF 1.5M LIF UNIT GENERAL: Sectionalization of the failure is performed by the LED indication of 1.5M LIF unit. APPARATUS: MCU console STEP PROCEDURE REFERENCE NO. Note 1: Mounting positions of LEDs and SW and the list of LED functions are shown in GSD-001 . Note 2: When the LED of the CH (channel) in use is lit, there is a failure in the line. However, LEDs in the unused channels are always lit. The...
Page 666
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-006 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 667
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-007 TROUBLESHOOTING OF RS-422 LIF UNIT GENERAL: Sectionalization of the failure is performed by the front lamp (LED) indication of RS-422 LIF unit. APPARATUS: MCU console STEP PROCEDURE REFERENCE NO. Note 1: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-002 . Note 2:In the case where the LED of the CH (channel) in use is lit, there is a failure in the line. However, LEDs in the unused...
Page 668
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-007 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 669
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-008 TROUBLESHOOTING OF H0-INF LIF UNIT GENERAL: Sectionalization of the failure is conducted by the front lamp (LED) indication of H0-INF LIF unit. APPARATUS: MCU console STEP PROCEDURE REFERENCE NO. Note 1: Location of SWs, Straps, LEDs, and list of LED function are shown in GSD-003 . Note 2: In the case where the LED of the CH (channel) in use is lit, there is a failure in the line. However, LEDs in the unused...
Page 670
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-008 MCU 5000A Multipoint Control Unit This page is for your notes.