NECA 34 0-4 14- 500 Revision 2.0 Page 13 of 14 MCU 5000A Multipoint Control U nit INT-001 9. HANDLING OF BACKUP MEMORY B ATTE RY IN M CONT UNIT A +? CN 2 C7C8 ON As seen for A OPER ATING CONDITION 24-H OUR DISCHARGE 8 HOUR/E AC H TIME DISCHARGE
Page 652
Page 14 of 14 NECA 3 40-4 14- 500 Re vis ion 2.0 INT-001 MCU 5000A Mult ipoint Con trol Unit D . Re placement of
Page 653
NECA 340-414-500 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit TCP-001 CHECK ON POWER SYSTEM GENERAL: Check on AC power supply and output voltages of PWR Unit is conducted. APPARATUS: Digital Multimeter (DDM) STEP PROCEDURE REFERENCE NO. 1 Turn ON the power switch of the MCU 5000A. 2 Is POWER LED of PWR Unit lit? If YES , go to Step 10 . If NO , go to Step 3 . 3 Set Digital Multimeter (DDM) range to measure 300 VAC. 4 Turn DDM power switch to ON. 5 Connect DDM test cord between DDM and...
Page 654
Page 2 of 4 NECA 340-414-500 Revision 2.0 TCP-001 MCU 5000A Multipoint Control Unit CHECK ON POWER SYSTEM Figure 1: Checking AC Line Voltage STEP PROCEDURE REFERENCE NO. 14 Does output voltage meet specified figure of +4.75 V through + 5.25 VDC? If YES, go to Step 15. If NO, go to Step 18. 15 CAUTION: BE CAREFUL OF THE POLARITY OF THE VOLTAGE CHECK TERMINAL. Connect one end of the test cord to the DDM and other end to the power terminal of PWR unit. (See Fig. 2) 16 Confirm that the measured...
Page 655
NECA 340-414-500 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit TCP-001 CHECK ON POWER SYSTEM Figure 2: Checking DC Output Voltage of PWR Unit MON CONF B A LMT MON OFFON MEM MCU 5000A PWR 19 990 +12VDC +5 VDC G -12 VDC
Page 656
Page 4 of 4 NECA 340-414-500 Revision 2.0 TCP-001 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 657
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-002 IMPLEMENTATION OF C&I LOOPBACK FUNCTION GENERAL: Operate a C&I remote loopback on specified terminals of VL 5000 using RLCS command referring to NECA 340-414-300 . APPARATUS: MCU console STEP PROCEDURE REFERENCE NO. 1 Has the MCU console been started up? If YES , go to Step 3 . If NO , go to Step 2 .TCP-016 2 Start up the MCU console and put it into communication state.TCP-016 3 Decide the number (1 to 8) of...
Page 658
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-002 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 659
NECA 340-414-500 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit TCP-003 SETTING OF MCU 5000A LOOPBACK POINTS GENERAL: Set MCU loopback on specified point of MCU 5000A using STLP command, referring to NECA 340-414-300 . APPARATUS: MCU console STEP PROCEDURE REFERENCE NO. 1 Has the MCU console been started up? If YES , go to Step 3 . If NO , go to Step 2 . 2 Start the MCU console up and put it into communication state.TCP-016 3 Decide test loopback points A to H shown in Fig.1. 4 Enter...
Page 660
Page 2 of 2 NECA 340-414-500 Revision 2.0 TCP-003 MCU 5000A Multipoint Control Unit Figure 1: MCU 5000A Loopback Point RELAY IPAF MTSC MTSC MTSCMTSC PN CHECKER PN GENERATOR POINT A POINT B POINT C POINT D POINT E POINT F1.5M LIF UNIT EC H221 MUX UNIT V SW/LSD UNIT HSCX A CODEC POINT H POINT G RELAY MTSC MTSC MTSCMTSC PN CHECKER PN GENERATOR POINT A POINT B POINT C POINT D POINT FRS-422 LIF UNIT EC H221 MUX UNIT V SW/LSD UNIT HSCX A CODEC POINT H POINT G (a) In case that MCU 5000A consists of 1.5M LIF...