    							NDA-30008   Revision 2.0Page 31
    Guardian Operations Manual Administration
    Procedure
    Action Result
    On the main menu, select the Set OAI 
    Application Logical Name option and 
    press Enter. (1)The Logical Name prompt highlights. 
    (2)
    Type the Logical Name of the desired 
    tenant from the configuration file and 
    press Enter.Following a 3-second delay, the 
    message Set Logical Name Successful 
    appears.
    Note:
    If the name you entered is not in 
    the configuration data or corre-
    sponds to a tenant that is not ini-
    tialized, the error message Error 
    Setting Logical Name
     appears, 
    and the field highlights again for 
    re-entry.
    Press ESC to exit. Control returns to the main menu. 
    						
    							Page 32NDA-30008   Revision 2.0
    Administration Guardian Operations Manual
    Modify Status
    OverviewThe Modify Status option on the main menu allows Administrators to modify the 
    disable status of a single group, authorization code, or extension. This option can 
    only be accessed under the Administrator password.
    Figure 3-3   Modify Status
    Notes
    The Modify Status option allows the Administrator to disable a group of 
    extensions, an authorization code, or a single extension in the following ways:
    Unconditionally – Disabled constantly and indefinitely, until enabled again by 
    the Administrator.  
    Routinely – Disabled during the time interval associated with the group, 
    authorization code, or extension in the database, as illustrated in the following 
    example:
    In the Group database, Group 2 is assigned an Interval Index of 5. In the Time 
    Interval database, Interval Index 5 is a period that starts Friday at 10:00 p.m. and 
    ends Monday at 5:30 a.m. When the System Administrator uses the Modify 
    Status option to indicate YES in the Routinely Disable: field for Group 2, all of 
    the extensions in this group are turned off during the Friday to Monday time 
    period until either this same field is again changed or the Interval Index is 
    changed.
    (1)
    (2)GUARDIAN
    *** SYSTEM  ADMINISTRATION ***
    Arrow keys to move cursor,  to select,  to quit
    Set OAI Application Logical Name
    >  Modify Status
    Query Database
    Initialize Batch Control
    Initialize Record File
    Generate Reports
    Maintain Password
    Clear Status Values
    Quit 
    GUARDIAN
    *** MODIFY STATUS ***
    Group Authorization
    Arrow keys to move cursor,  to select,  to quit
    Code Extension
    Quit  
    						
    							NDA-30008   Revision 2.0Page 33
    Guardian Operations Manual Administration
    Notes (Continued)
    The System Administrator can also override the System Disable of an extension 
    using this option. When Guardian has temporarily turned off an extension that has 
    been used in an excessive number of invalid call attempts, the administrator can use 
    this option to turn on the extension without altering the System Disable parameters 
    in the Extension database. The next time the number of invalid call attempts on that 
    extension exceeds the tolerated frequency, Guardian disables the extension again.
    The ID database can only be modified through the Database Administration option 
    in the APM. The Guardian Modify Status option cannot access the ID database.
    There are two kinds of errors that may occur in the Modify Status option:
    Database Record Not Found: If the system cannot find the record for the 
    number you enter (group ID, authorization code, or extension number), this 
    error message appears. Press ESC and re-enter the number. If the error message 
    appears again, check the record through the APM master database and use the 
    Process/Install command to reinstate the working database. If the error persists, 
    call the system distributor.
    Error Processing Modification to Database: If the record has been retrieved 
    and the status modification has been entered, this message appears. If this 
    occurs, call the system distributor.
    Procedure
    Action Result
    On the main menu, select the Modify 
    Status option and press Enter.  (1)The Modify Status menu displays.  (2)
    Using the arrow keys to move the 
    cursor, select the desired menu option 
    and press Enter.A selection screen for the option 
    displays.
    To exit the Modify Status menu, select 
    the Quit option and press Enter, or press 
    ESC.The main menu reappears. 
    						
    							Page 34NDA-30008   Revision 2.0
    Administration Guardian Operations Manual
    GroupThe Group option on the Modify Status menu allows Administrators to alter the 
    disable status of all the extensions in a group simultaneously.
     When you select the 
    Group option, the Modify Group screen displays.
    Figure 3-4   Modify Group
    Notes
    If the group is set to be unconditionally disabled (Yes), all of its extensions are 
    disabled indefinitely as soon as this procedure is completed. If the group is set to 
    be routinely disabled (Yes), all of its extensions are regularly disabled during the 
    time interval that is designated by the Interval Index in the group database record. 
    (You can review the database record using the Query Database option on the 
    System Administration menu or by entering the APM Database Administration 
    option.)    
    (1)GUARDIAN
    *** MODIFY STATUS ***
    >  Group
    Arrow keys to move cursor,  to select,  to quit
    Authorization Code
    Extension
    QuitGUARDIAN
    *** MODIFY  GROUP ***
    Group ID:
     to accept,  to quit
    1Unconditionally Disable:
    Routinely Disable:Yes
    No
    (2) 
    						
    							NDA-30008   Revision 2.0Page 35
    Guardian Operations Manual Administration
    Procedure
    Action Result
    On the Modify Status screen, select the 
    Group option and press Enter.  (1)The Group Selection screen displays 
    with a prompt for the Group ID.
    Type the ID of the group and press 
    Enter.
    Note:
    Press ESC to exit the screen and 
    redisplay the Modify Status 
    menu.
    The Modify Group screen displays 
    showing the current status of the group 
    in the second field (Yes or No).   (2)
    Note:
    If the system does not recognize 
    the Group ID you entered, the 
    message Error Database Record 
    Not Found
     appears. Press ESC 
    and try again, or exit and query 
    the database.
    Enter the desired status to each field 
    (Ye s or No), pressing Enter after each 
    entry.The message Modify Group Status 
    Successful appears.
    Note:
    If you enter anything other than 
    Yes or No in the disable fields, the 
    message Error Processing Sta-
    tus Modification
     appears. Either 
    press ESC to return to the Modify 
    Status menu or re-enter the cor-
    rect status and press Enter. 
    Press ESC to exit the screen. The Group Selection screen reappears 
    for entry of another Group ID.
    Press ESC again to exit the Selection 
    screen.The Modify Status menu reappears. 
    						
    							Page 36NDA-30008   Revision 2.0
    Administration Guardian Operations Manual
    Authorization 
    CodeAdministrators can use the Authorization Code option on the Modify Status menu 
    to change the disable status of the designated authorization code.
     When you select 
    this option, the Modify Authorization Code screen displays.
    Figure 3-5   Modify Authorization Code
    Notes
    If the authorization code is set to be unconditionally disabled (Yes), it is disabled 
    indefinitely as soon as this procedure is completed. If the authorization code is set 
    to be routinely disabled (Yes), the authorization code is regularly disabled during 
    the time interval that is designated by the Interval Index in the authorization code 
    database record. (You can review the database record using the Query Database 
    option on the System Administration menu or by entering the APM Database 
    Administration option.) 
    (1)
    (2)GUARDIAN
    *** MODIFY STATUS ***
    Group
    Arrow keys to move cursor,  to select,  to quit
    >  Authorization Code
    Extension
    QuitGUARDIAN
    *** MODIFY  AUTHORIZATION  CODE ***
    Authorization Code:
     to accept,  to quit
    0987654Unconditionally Disable:
    Routinely Disable:Yes
    No 
    						
    							NDA-30008   Revision 2.0Page 37
    Guardian Operations Manual Administration
    Procedure
    Action Result
    On the Modify Status screen, select the 
    Authorization Code option and press 
    Enter.  (1)The Authorization Code Selection 
    screen displays with a prompt for the 
    authorization code.
    Enter the authorization code and press 
    Enter.
    Note:
    Press ESC to exit the screen and 
    redisplay the Modify Status 
    menu.
    The Modify Authorization Code screen 
    displays showing the current status of 
    the code in the second and third fields 
    (Yes or No). (2)
    Note:
    If the system does not recognize 
    the Authorization Code you en-
    tered, the message Error Data-
    base Record Not Found
     appears.  
    Press ESC and try again or exit 
    and query the database.
    Enter the desired status to each field 
    (Ye s or No), pressing Enter after each 
    entry.The message Modify AuthCode 
    Status Successful appears.
    Note:
    If you enter a value other than 
    Yes or No in either of the disable 
    fields, the message Error Pro-
    cessing Status Modification
     ap-
    pears.  Either press ESC to return 
    to the Modify Status menu or re-
    enter the correct status and press 
    Enter. 
    Press ESC to exit the screen. The Authorization Code Selection 
    screen reappears for entry of another 
    authorization code.
    Press ESC again to exit the Selection 
    screen.The Modify Status menu reappears.  
    						
    							Page 38NDA-30008   Revision 2.0
    Administration Guardian Operations Manual
    ExtensionAdministrators can use the Extension option on the Modify Status menu to change 
    the disable status of an extension.
      When you select this option, the Modify 
    Extension screen displays.
    Figure 3-6   Modify Extension
    Notes
    If the extension is set to be unconditionally disabled (Yes), it is disabled 
    indefinitely as soon as this procedure is completed.  If the extension is set to be 
    routinely disabled (Yes), the extension is regularly disabled during the time 
    interval that is designated by the Interval Index in the authorization code database 
    record.  (You can review the database record using the Query Database option on 
    the System Administration menu or by entering the APM Database Administration 
    option.)
    The Administrator can override the system disable setting of any extension.  If the 
    Administrator needs to turn on an extension after it has been turned off by the 
    system, the Administrator may set the override field to Yes.  This override affects 
    only the current system disabling of the extension; it does not protect the extension 
    from being disabled after another episode excessive invalid call attempts.  (‘No’ is 
    the default setting in this field.)
    (2) (1)
    GUARDIAN
    *** MODIFY STATUS ***
    Group
    Arrow keys to move cursor,  to select,  to quit
    Authorization Code
    >  Extension
    Quit
     to accept,  to quit GUARDIAN
    *** MODIFY  EXTENSION ***
    Extension No:
    3201Unconditionally Disable:
    Routinely Disable:
    Override System Disable:Yes
    No
    No 
    						
    							NDA-30008   Revision 2.0Page 39
    Guardian Operations Manual Administration
    Procedure
    Action Result
    On the Modify Status screen, select the 
    Extension option and press Enter.  (1)The Extension Selection screen 
    displays with a prompt for the 
    extension.
    Enter the extension and press Enter.
    Note:
    Press ESC to exit the screen and 
    redisplay the Modify Status 
    menu.
    The Modify Extension screen displays 
    showing the three disable statuses for 
    the indicated extension.  (2)
    Note:
    If the system does not recognize 
    the Extension you entered, the 
    message Error Database Record 
    Not Found
     appears.  Press ESC 
    and try again or exit and query 
    the database.
    Enter the desired status to each field 
    (Ye s or No), pressing Enter after each 
    entry.The message Modify Extension 
    Status Successful appears.
    Note:
    If you enter a value other than 
    Yes or No in any of the disable 
    fields, the message Error Pro-
    cessing Status Modification
     ap-
    pears.  Either press ESC to return 
    to the Modify Status menu or re-
    enter the correct status and press 
    Enter. 
    Press ESC to exit the screen. The Extension Selection screen 
    reappears for entry of another 
    extension.
    Press ESC again to exit the Selection 
    screen.The Modify Status menu reappears.  
    						
    							Page 40NDA-30008   Revision 2.0
    Administration Guardian Operations Manual
    Query Database
    OverviewUse the Query Database option on the main menu to view the records of a working 
    database.  You can access this option with either the Administrator or the Operator 
    password.  When you select this option, the Query Database Menu displays for one 
    of the three databases.
    Figure 3-7   Query Database
    Notes
    Using this option, the System Administrator or Operator can review records in any 
    of the five working databases.  These databases include the fields maintained 
    through the APM Database Administration menu and the current disable status of 
    each group, authorization code, or extension.  The Query option provides a view-
    only display of the databases.  You cannot make changes through this option.
    If the system cannot find the record for the number you entered (group ID, 
    authorization code, or extension number), the error message Database Record Not 
    Found appears.  Press ESC and re-enter the number.  If the message occurs again, 
    check the record through the APM master database and use the Process/Install 
    command to reinstate the working database.  If the error persists, call the system 
    distributor.
    (1)
    (2)GUARDIAN
    *** SYSTEM  ADMINISTRATION ***
    Arrow keys to move cursor,  to select,  to quit
    Set OAI Application Logical Name
    Modify Status
    >  Query Database
    Initialize Batch Control
    Initialize Record File
    Generate Reports
    Maintain Password
    Clear Status Values
    Quit 
    GUARDIAN
    *** QUERY  DATABASE ***
    Group
    Arrow keys to move cursor,  to select,  to quit
    Authorization Code
    Extension
    Time Interval
    ID
    Quit 
    						