NEC Dtl8r1 Manual
Have a look at the manual NEC Dtl8r1 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Owner’s Manual2-1 Chapter 2About the Dterm Cordless DECT SECTION 1 OVERVIEW The DTZ-8R-1 (Dterm Cordless DECT) is a cordless telephone for the NEC PBX (Private Branch Exchange) or key telephone system. It is designed for use in the office environment. Optionally, an NEC D term multiline (wired) desk phone (such as DT400 series) can be connected. This gives the user the option of using either the cordless handset or the wired desk phone. However, in this configuration the Cordless Handset and wired phone cannot be used at the same time. Figure 2-1 Dterm System Overview PBX or Key Telephone System Base Unit Handset Wired Desk Phone (Optional)
Issue 1.0 2-2About the D term Cordless DECT SECTION 2 ITEMS INCLUDED WITH THE Dterm CORDLESS DECT Congratulations on your purchase of the Dterm Cordless DECT. This telephone is designed and engineered to exacting standards for reliability, long life and outstanding performance. To become familiar with the features of the cordless telephone, read this manual thoroughly. The D term Cordless DECT includes the following items: CAUTION ❍The Cordless Handset and wired telephone cannot be used at the same time. ❍The Handset and Base Station must have the original ID that is written on each unit at the factory. Figure 2-2 Items Included with the Dterm Cordless DECT Base UnitTelephone Cord 2 AC Adapters 2 Rechargeable BatteriesBelt Clip Charging Unit Base Unit Stand Green Tipped Adapter Plug - used with Charging Unit Yellow Tipped Adapter Plug - used with Base Unit Handset
Issue 1.0 Owner’s Manual2-3 SECTION 3 FEATURES OF THE CORDLESS TELEPHONE The Dterm Cordless DECT provides a variety of features. These features are listed below. 1.9G (1920~1930 MHz) 5 Channels Display: 240x320 dots (QVGA) 8 Programmable Keys: (Soft Keys) Headset Jack Mute Control AutoStandby ® Handset/Headset/Handsfree Volume Control Adjustable Ringer Volume Control 6 Selectable Ring Tones Vibrating Ringer Out of Range Detection and Alarm Tone LCD Backlight Automatic Channel Selection Single Key Access to: Conference, Hold, Transfer and Redial features Wall Mountable Separate Charging Unit Easy Installation Compact Handset Design Use with an NEC Digital Multiline Telephone On the SV9100, the Dterm Cordless DECT can be used in conjunction with the DTL and DTZ multiline telephones. With SV9300, the Dterm Cordless DECT can be used in conjunction with the Dterm , DTH, DTL and DTZ multiline telephones. SECTION 4 Dterm CONTROLS AND FUNCTIONS The primary components of the Dterm Cordless DECT consist of the handset and the base unit. Before using the telephone for the first time, you should become familiar with the controls and functions of the handset and base unit.
Issue 1.0 2-4About the D term Cordless DECT 4.1 Handset The handset is used to make/receive calls. The various buttons and LCD provide access to and provide indication of the various functions and operations of the phone. Figure 2-3 DTZ-8R-1 Handset Controls and Functions on page 2-4 provides a layout of various controls and functions available with the handset. For a detailed description of the buttons, refer to Chapter 4 D term Handset, Base Unit and Charging Unit, Section 1 Handset Controls on page 4-1. Figure 2-3 DTZ-8R-1 Handset Controls and Functions 1. Headset Jack 7. Mute/Menu Key 2. Message Display 8. End Call Key 3. Soft Keys (used for HOLD, CONF, TRANSFER, REDIAL, etc.)9. Center Key 4. Handsfree Speaker Key 10. Handset/Ringer Volume (Increase ▲ / Decrease ▼) LCD Contrast (Increase ► / Decrease◄) 5. Answer Key 11. Microphone 6. Numeric Keypad 12. Belt Clip 1 2 3 69 4 712 11 58 10
Issue 1.0 Owner’s Manual2-5 4.2 Base Unit The Base Unit allows users to switch between the Dterm Cordless DECT phone and the wired (desk) phone by using the Desk/Cordless buttons on the unit. Figure 2-4 Base Unit Controls and Functions BOTTOM VIEW 4 123 1. Power LED 4. Modular Jacks 2. Cordless Button 5. Power Jack 3. Desk Button FRONT VIEW 5 123
Issue 1.0 2-6About the D term Cordless DECT 4.3 Cordless Handset/Desk Phone Switch (Base Key Option) It is possible to select between cordless handset operation and desk phone operation using the cordless handset. To enable this feature, the Base Key Option setting must be set to On. (Base Key Option is set to Off by default.) To enter the Base Key Option setting: 1. Press the Mute/Menu key followed by 1, 2, 3, # on the numeric keypad. 2. Scroll down to the Base Key Option setting and select On. 3. With Base Key Option set to On, press the Center key. The Desk and H/S soft keys should be displayed. 4. Select Desk for desk phone operation. 5. Select H/S for cordless handset operation.
Issue 1.0 Owner’s Manual2-7 4.4 Charging Unit The Charging Unit is used to recharge the batteries in the handset. Figure 2-5 Charging Unit
Owner’s Manual3-1 Chapter 3Installation SECTION 1 SELECTING A LOCATION Select a location for the Dterm Cordless DECT to avoid excessive heat or humidity. The base unit of the Dterm Cordless DECT can be placed on a desk or tabletop near a standard 120 Vac outlet and telephone line jack. The base unit can also be mounted on a standard wall plate using the wall mount adapter. Keep the base unit and handset away from sources of electrical noise (motors, fluorescent lighting, computers, PC monitor). Refer to Chapter 1 Specifications and Safety Information for a complete discussion of safety precautions. SECTION 2 INSTALLATION PRECAUTIONS To ensure optimum performance follow these guidelines. Each base unit must be placed at least 20 feet (6m) apart. Always place the base unit on top of a desk or on higher shelves. Avoid locations surrounded by metal surfaces. Place the base unit away from any electrical component such as a PC, monitor and other telephone. SECTION 3 CONNECTING THE TELEPHONE CORDS When connecting the telephone cords, observe the following precautions. Never install telephone wiring during a lightning storm. Never touch bare telephone wires or terminals unless the telephone line has been disconnected at the network interface. Use caution when installing or modifying telephone lines.
Issue 1.0 3-2Installation To connect the telephone cords: 1. Connect one line cord from NEC’s PBX (or key system) digital station port to the Line In connector on the D term Cordless DECT base unit. Connect another line cord from the Line Out connector to a qualified D term multiline telephone. Figure 3-1 Connecting Telephone Cords NOTE Do not connect the DTZ-8R-1 line cord directly to PBX station card as the DTZ-8R-1 will not function. Connect the line cord to the jack with a single pair connected back to one digital station port. Line In To PBX (or key system) digital station port. Line Out Connect to the desk phone.