NEC Dsx 34b Manual
Here you can view all the pages of manual NEC Dsx 34b Manual. The NEC manuals for Software are available online for free. You can easily download all the documents as PDF.
Page 711
16xx-Timers 160x-Feature Timers 1605-Control Timers DSX Software ManualSystem Options: 1001-1702◆681 System 1001-1702 1605-04: Forced Program Exit Timer (Program Exit) Use this option to set the Forced Program Exit timer. If a telephone in the programming mode is inactive longer than this interval, the system automatically cancels the programming mode and makes the telephone idle. Features • None Intr aMail Features • None Options •1-9999 seconds • 0 for disabled Default •120 seconds 1605-05: Backlight...
Page 712
16xx-Timers 161x-COI (Analog Line) Timers 1611-Incoming 682◆System Options: 1001-1702 DSX Software Manual 161x-COI (Analog Line) Timers 1611-Incoming Description Use this program to adjust timers that affect incoming calls on the line (COIU) PCBs. Options 1611-01: Minimum Ring Detect Timer (Ring Detect) Use this option to set the threshold for ring detection. If the ring sig\ nal is longer than this interval, the system interprets the signal as valid ringing. If the signal is equal to or shorter than...
Page 713
16xx-Timers 161x-COI (Analog Line) Timers 1611-Incoming DSX Software ManualSystem Options: 1001-1702◆683 System 1001-1702 1611-03: Minimum Double Ring Detection Off Timer (Double Ring Min) The system uses this option to detect valid double ring from the connected PBX. Valid double ring must be longer than this interval. F eatures • None Intr aMail Features • None Options •8-2040 mS Default •288 mS
Page 714
16xx-Timers 161x-COI (Analog Line) Timers 1611-Incoming 684◆System Options: 1001-1702 DSX Software Manual 1611-04: Maximum Double Ring Detection Off Timer (Double Ring Max) The system uses this option to detect valid double ring from the connected PBX. Valid double ring must be less than this interval. F eatures • None Intr aMail Features • None Options •8-2040 mS Default •576 mS 1611-05: Ringing Signal End Detection Timer (Ring Stop) Use this option to set the Ringing Signal End Detection time. If the...
Page 715
16xx-Timers 161x-COI (Analog Line) Timers 1612-Outgoing DSX Software ManualSystem Options: 1001-1702◆685 System 1001-1702 1612-Outgoing Description Use this program to adjust timers that affect outgoing calls on the line (COIU) PCBs. Options 1612-01: DP Break Timer (Break Time) Use this timer to set the duration of the Dial Pulse Break signal (i.e.\ , relay open). This is the “off” time in a Dial Pulse digit. Set this timer for compatibility with the connected te\ lco or PBX/Centrex. Keep in mind that...
Page 716
16xx-Timers 161x-COI (Analog Line) Timers 1612-Outgoing 686◆System Options: 1001-1702 DSX Software Manual Options •100-9999 mS Default •800 mS 1612-04: PBX/Centrex Flash Timer (Flash 1 Time) Use this timer to set the Flash interval. When a user flashes a line (manually or in a Speed Dial number), the system opens the line circuit for this interval. For accurate flash function, be sure to set this interval for com- patibility with the connected telco or PBX/Centrex. If you set this interval too short,...
Page 717
16xx-Timers 161x-COI (Analog Line) Timers 1612-Outgoing DSX Software ManualSystem Options: 1001-1702◆687 System 1001-1702 1612-07: Shunt Pause Timer (Shunt Pause) Use this option to set the Shunt Pause Timer (Dial Pulse Mute Timer) for the ATRU PCB. While dial pulsing or doing a Flash, the ATRU PCB switches a low resistance shunt across tip and ring to maintain the correct impedance on the line. When dialing or flashing is complete, the ATRU PCB waits this interval before releasing the shunt. This...
Page 718
16xx-Timers 161x-COI (Analog Line) Timers 1613-Loop Control 688◆System Options: 1001-1702 DSX Software Manual 1613-Loop Control Description Use this program to adjust timers that affect the loop on the line (COIU) PCBs. Options 1613-01: Loop Current Detection Timer (Loop Detect) For loop start lines, loop current must be present for this interval before the system seizes the line. Set this interval for compatibility with the connected telco or PBX/Centrex. If you set this interval too short, the sys-...
Page 719
16xx-Timers 161x-COI (Analog Line) Timers 1613-Loop Control DSX Software ManualSystem Options: 1001-1702◆689 System 1001-1702 1613-03: Power Failure Recovery Detect Timer (Loop Recovery) Use this option to set the Power Failure Recovery Detect time. When the ATRU or COIU PCB recovers from a power failure, it checks the power failure line for loop current for this interval. If loop current is detected, it assumes the power failure telephone is still connected and does not tear down the call. If loop...
Page 720
16xx-Timers 162x-SLI (Analog Single Line) Timers 1621-Incoming 690◆System Options: 1001-1702 DSX Software Manual 162x-SLI (Analog Single Line) Timers 1621-Incoming Description Use this program to adjust the timers that affect incoming calls to analog single line telephones. Options 1621-01: Minimum DP Break Timer (Minimum Break) Use this option to define the minimum amount of time the loop must be opened to properly decode\ the dial pulse digits sent from analog devices connected to single line PCBs....
All NEC manuals