16xx-Timers 162x-SLI (Analog Single Line) Timers 1621-Incoming DSX Software ManualSystem Options: 1001-1702◆691 System 1001-1702 1621-03: Minimum DP Make Timer (Minimum Make) Use this option to de fine the minimum amount of time the loop must be closed to properly decode\ the dial pulse digits sent from analog devices connected to single line PCBs. Change this value only if the con- nected analog devices are set to dial at a rate other than 10 PPS. F eatures • None Intr aMail Features • None Options...
Page 722
16xx-Timers 162x-SLI (Analog Single Line) Timers 1621-Incoming 692◆System Options: 1001-1702 DSX Software Manual 1621-04: Maximum DP Make Timer (Maximum Make) Use this option to define the maximum amount of time the loop must be closed to properly decode\ the dial pulse digits sent from analog devices connected to SLIU PCBs. Change this value only if the connected analog devices are set to dial at a rate other than 10 PPS. F eatures • None Intr aMail Features • None Options •5-1275 mS Default •100...
Page 723
16xx-Timers 162x-SLI (Analog Single Line) Timers 1621-Incoming DSX Software ManualSystem Options: 1001-1702◆693 System 1001-1702 IntraMail Features • None Options •5-1275 mS Default •105 mS 1621-08: Dial Pulse Guard Timer (Dial Pulse Guard) Use this option to set the interval the single line PCB waits between dial pulse digits before attempting to detect any additional DP digits. This timer helps prevent erroneous DP dialing due to hardware stabilization. F eatures • None Intr aMail Features • None...
Page 724
16xx-Timers 162x-SLI (Analog Single Line) Timers 1622-Outgoing 694◆System Options: 1001-1702 DSX Software Manual 1622-Outgoing Description Use this program to adjust the timers that affect outgoing calls from analog single line telephones. Options 1622-01: Loop Disconnect Timer (Loop Disconnect) Use this option to determine how long the single line PCB opens the loop to the connected analog device after the far end disconnects. This timer is used only if 1403-06: Loop Disconnect for Single Line Set...
Page 725
16xx-Timers 163x-T1/E1 Timers 1631-Incoming DSX Software ManualSystem Options: 1001-1702◆695 System 1001-1702 163x-T1/E1 Timers 1631-Incoming Description Use this program to adjust the timers that affect incoming T1/E1 calls. Options 1631-01: Receive Loop Detection Timer (Rx Loop Detect) For loop start T1 lines, loop current must be present for this interval before the system seizes the line. Set this interval for compatibility with the T1 service provider. If you set this interval too short, the...
Page 726
16xx-Timers 163x-T1/E1 Timers 1631-Incoming 696◆System Options: 1001-1702 DSX Software Manual Options •4-1020 mS Default •104 mS 1631-04: Receive Dial Pulse Minimum Make Timer (Rx Min Make) Use this option to set the minimum required duration of the T1 circuit receive Dial Pulse Make signal (i.e., relay closed). This is the minimum “on” time in a Dial Pulse digit. Set this time\ r for compatibility with the T1 service provider. Keep in mind that there are three components of a Dial Pulse digit: Make...
Page 727
16xx-Timers 163x-T1/E1 Timers 1631-Incoming DSX Software ManualSystem Options: 1001-1702◆697 System 1001-1702 1631-07: Receive Maximum Flash Timer (Rx Max Flash) Information to be provided. F eatures •T1 Lines (page 338) Intr aMail Features • None Options •16-4080 mS Default •1008 mS 1631-08: Receive Minimum Clear Signal Timer (Rx Min Clear) Information to be provided. F eatures •T1 Lines (page 338) Intr aMail Features • None Options •16-4080 mS Default •400 mS
Page 728
16xx-Timers 163x-T1/E1 Timers 1632-Outgoing 698◆System Options: 1001-1702 DSX Software Manual 1632-Outgoing Description Use this program to adjust the timers that affect outgoing T1/E1 calls. Options 1632-01: Transmit Dial Pulse Break Timer (Tx Break Time) Use this option to set the duration of the T1 circuit transmit Dial Pulse Break signal (i.e., relay open). This is the “off” time in a Dial Pulse digit. Set this timer for compatibility with \ the T1 service provider. Keep in mind that there are...
Page 729
16xx-Timers 163x-T1/E1 Timers 1632-Outgoing DSX Software ManualSystem Options: 1001-1702◆699 System 1001-1702 IntraMail Features • None Options •16-4080 mS Default •800 mS 1632-04: Transmit Flash Timer (Tx Flash Time) Information to be provided. F eatures •T1 Lines (page 338) Intr aMail Features • None Options •16-4080 mS Default •800 mS 1632-05: Transmit Clear Signal Timer (Tx Clear Time) Information to be provided. F eatures •T1 Lines (page 338) Intr aMail Features • None Options •16-4080 mS...
Page 730
16xx-Timers 164x-T1 Specific Timers 1641-Ring Detect 700◆System Options: 1001-1702 DSX Software Manual 164x-T1 Specific Timers 1641-Ring Detect Description Use this program to adjust the T1 Ring Detect timers. Options 1641-01: Minimum Ring Detect Timer (Ring Detect) Information to be provided. F eatures •T1 Lines (page 338) Intr aMail Features • None Options •8-2040 mS Default •104 mS 1641-02: Single Ring Minimum Detection Timer (Single Ring Min) Information to be provided. F eatures •T1 Lines (page...