NEC Ds2000 Software Instructions Manual
Here you can view all the pages of manual NEC Ds2000 Software Instructions Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
Initial System Startup DS1000/2000 Software ManualChapter 1: Features13 Step 5: Assign the correct circuit type to your installed extensions. • In Program 1801 - Extension Circuit Type (page 532), enter the correct circuit type for each installed extension: 00 = Uninstalled 01 = 22-Button Standard 02 = 22-Button Display 06 = 34-Button Display 09 = 34-Button Super Display 10 = Digital Door Box [1] 15 = Analog station 21 = 2OPX (DS2000 Only) • All keysets default to type 02 (22-Button Dis- play). If you...
Page 22
Initial System Startup 14Chapter 1: FeaturesDS1000/2000 Software Manual Step 8: Does your system have Voice Mail? • Turn to Voice Mail on page 414 and review the required Voice Mail programming. • Go to the next step. Step 9: Do you want to change the default system passwords? • In Program 9905 - Password (page 566), change the passwords from their default settings. • In Program 9905 - Password (page 566), do not change the passwords from their default settings. Step 10: Do you want to return the...
Page 23
Charts and Illustrations DS1000/2000 Software ManualChapter 1: Features15 Charts and Illustrations Table 1: Dial Codes (by Feature) For this feature Dial this code When you are Barge In (Intrusion) 4 Barging-In on a co-worker’s call Call Forwarding ICM + *30 Canceling Call Forwarding at an extension ICM + *32 + Extension or 0 (for the operator)Enabling Call Forwarding Busy/No Answer ICM + *34 + Extension or 0 (for the operator)Enabling Call Forwarding All Calls ICM + *36 + Extension or 0 (for the...
Page 24
Charts and Illustrations 16Chapter 1: FeaturesDS1000/2000 Software Manual Paging *1 + Page zone (1-7 or 0 for All Call) Making an internal Paging announce- ment Park ICM + ** + System Park Orbit (60-69) Parking or retrieveing a call from Sys- tem Park Orbit ICM + ** + Extension (e.g., 301)Using Personal Park to Park or retrieve a call at a co-workers extension Removing Trunks and Extensions From ServiceICM + #40 + Extension (e.g., 301) or trunk (e.g., 401) + 4 (to return) or 6 (to remove)Removing or...
Page 25
Charts and Illustrations DS1000/2000 Software ManualChapter 1: Features17 Table 2: System Number Plan/Capacities (Page 1 of 3) DS1000DS2000 4-SlotDS2000 8-Slot System Options • Classes of Service 1-15 (COS 1 normally reserved for attendants) • Conference 32 simultaneous users in Conference (total of all Conferences system-wide) 8 simultaneous Conferences maximum 8 parties maximum in any one Conference • Extension Hunting (ACD/ UCD) Master Numbers8 • Extension Hunting Groups 8 (1-8) • Group Call Pickup...
Page 26
Charts and Illustrations 18Chapter 1: FeaturesDS1000/2000 Software Manual Extensions • Attendant (Operator) Access Number0 (single operator) 01-04 (multiple operators) • Attendants 4 • Digital Door Boxes Each Digital Door Box uses one digital station port. The System Load Factor may limit the total number you can install. See DS2000 Load Factor on page 3 and DS1000 Load Factor on page 9. Not available in DS2000 Fixed Slot software. • Analog Door Boxes 2 2nd Analog Door Box requires Expansion PCB 0...
Page 27
Charts and Illustrations DS1000/2000 Software ManualChapter 1: Features19 • Page Relays One set in each Analog Door Box jack (DOOR1 and DOOR2)One set on CPRU • Park Orbits 10 (60-69) Orbits 68 and 69 have extended (5 min.) timers Passwords • System Administrator 1 (Level 1)0000 • System Administrator 2 (Level 2)9999 • Installer (Level 3) 372000Table 2: System Number Plan/Capacities (Page 3 of 3) DS1000DS2000 4-SlotDS2000 8-Slot
Page 28
Charts and Illustrations 20Chapter 1: FeaturesDS1000/2000 Software Manual Figure 1: 22-Button Display Telephone (Fixed Slot) 123 456 789 0 ABC DEF MW ICM FLASH DND DIAL MIC LND SPK CONF HOLD GHI JKL MNOMNO PQRS TUV OPER VOLWXYZ CLEAR CHECK 80000 - 21A LINE 1 LINE 2 LINE 3 LINE 4 LINE 5 LINE 6 LINE 7 LINE 8 FIXED LOOP 0FIXED LOOP 0AUTO TIMERALL PAGE BIN 1 BIN 2 BIN 3 BIN 4 BIN 5 BIN 6 BIN 7 BIN 8 BIN 9 BIN 10 For...
Page 29
Charts and Illustrations DS1000/2000 Software ManualChapter 1: Features21 Figure 2: 22-Button Display Telephone (U Slot and DS1000) 123 456 789 0 ABC DEF MW ICM FLASH DND DIAL MIC LND SPK CONF HOLD GHI JKL MNOMNO PQRS TUV OPER VOLWXYZ CLEAR CHECK 80000 -62A LINE 1 LINE 2 LINE 3 LINE 4 LINE 5 LINE 6 LINE 7 LINE 8LINE 9 LINE 10 LINE 11 LINE 12 BIN 1 BIN 2 BIN 3 BIN 4 BIN 5 BIN 6 BIN 7 BIN 8 BIN 9 BIN 10 For Attendants:...
Page 30
Charts and Illustrations 22Chapter 1: FeaturesDS1000/2000 Software Manual Figure 3: 22-Button Standard Telephone (Fixed Slot) 123 456 789 0 ABC DEF MW ICM FLASH DND DIAL MIC LND SPKR CONF HOLD GHI JKL MNOMNO PQRS TUV OPER VOLWXYZ CLEAR CHECK 80000 - 22A LINE 1 LINE 2 LINE 3 LINE 4 LINE 5 LINE 6 LINE 7 LINE 8 FIXED LOOP 0FIXED LOOP 0AUTO TIMERALL PAGE For Attendants: Key 11=Night Key Key 12=Operator Call Key