NEC Ds2000 Software Instructions Manual
Here you can view all the pages of manual NEC Ds2000 Software Instructions Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
DS2000 System Configuration DS1000/2000 Software Manual Chapter 1: Features 3 DS2000 System Configuration DS2000 Load Factor The total number of components you can install and connect to your DS2000 system depends on power supply capacity and the System Load Factor. Read the following notes, then turn to DS2000 System Load Factor Calculations on page 4 to calculate the System Load Factor. Notes for Fixed Slot Software • Fixed slot (01.nn.nn) software is only compatible with 4 slot...
Page 12
DS2000 System Configuration 4 Chapter 1: Features DS1000/2000 Software Manual DS2000 System Load Factor Calculations To check your system configuration: 1. Indicate the quantity for each item installed in the Qty column. 2. For each item, multiply the Qty times the Load Factor and enter the value in the Total Load column. 3. Add all the values in the Total Load column and enter the value in Item 1 . 4. Determine the System Load Factor capacity of the power supplies...
Page 13
DS2000 System Configuration DS1000/2000 Software ManualChapter 1: Features5 Examples of Typical DS2000 4-Slot Cabinet Maximum Configurations Note that only the first configuration listed below (16 x 32) applies to Fixed Slot software. Refer to the Release Notes that came with your system to find out if you have Fixed Slot software. 16 x 32 (16 trunks and 32 digital extensions) Recommended for sites with no Voice Mail and high trunk usage. 24 x 16 (24 trunks and 16 digital extensions) Recommended for sites...
Page 14
DS2000 System Configuration 6Chapter 1: FeaturesDS1000/2000 Software Manual 32 x 32 x 16 (32 trunks, 32 digital extensions and 16 analog extensions) Recommended for sites with Voice Mail, high trunk usage and high analog extension usage. This configuration requires 2 power supplies. 16 x 64 x 16 (16 trunks, 64 digital extensions and 16 analog extensions) Recommended for sites with Voice Mail, normal to low trunk usage and low analog extension usage. This configuration requires 3 power supplies. DS2000...
Page 15
DS2000 System Configuration DS1000/2000 Software ManualChapter 1: Features7 Configuration 2 - with CPU P/N 80025A For Software Versions 02.01.07 and Higher Slot CN1 = 16DSTU PCB (extensions 300-315) Slots CN2-CN8 = Undefined Slots CN5-CN8 are not provided by the 4 slot cabinet hardware (i.e., cannot physically be installed) The database provides the capability to program all 48 trunks and 96 extensions. For Software Versions Prior to 02.01.07 Following is the default PCB configuration for a 4 slot...
Page 16
DS2000 System Configuration 8Chapter 1: FeaturesDS1000/2000 Software Manual DS2000 8 Slot Cabinet (with U Slot Software) Hardware Configuration For Software Versions 02.01.07 and Higher Slot CN1 = 16DSTU PCB (extensions 300-315) Slots CN2-CN8 = Undefined The database provides the capability to program all 48 trunks and 96 extensions. For Software Versions Prior to 02.01.07 Following is the default PCB configuration for an 8 slot cabinet with U Slot software prior to soft- ware version 2.01.07. Note that...
Page 17
DS1000 System Configuration DS1000/2000 Software ManualChapter 1: Features9 DS1000 System Configuration DS1000 Load Factor DS1000 System Load Factor Calculations The combination of extensions, Digital Door Boxes and DSS Consoles you can connect to your system may be limited by the System Load Factor. Use the DS1000 System Load Factor Calcula- tions chart below to verify your system’s configuration. To check your system configuration: 1. Indicate the quantity for each item installed in the Qty column. 2....
Page 18
DS1000 System Configuration 10Chapter 1: FeaturesDS1000/2000 Software Manual DS1000 Default Setup Using the factory installed default configuration, your DS1000 system provides: For more on installing the DS1000 Expansion PCB, refer to the DS1000 Quick Setup Guide (P/N 80200QSET**) that came with your system. Base Expansion Total Trunks 3 3 6 Digital Extensions 8 8 16 Analog Extensions 4 4 8 Analog Door Boxes 1 1 2 Relays 1 1 2 Page Output 1 - 1 Music Input 1 - 1
Page 19
Initial System Startup DS1000/2000 Software ManualChapter 1: Features11 Initial System Startup Default Feature Setup DS2000 Fixed Slot Software (01.nn.nn) All trunks are loop start DTMF Use Program 1001 - Trunk Circuit Type (page 498) to change this assignment. All extensions are 22-Button Display models. Use Program 1801 - Extension Circuit Type (page 532) to change this assignment. Trunks 1-8 ring on line keys 1-8. Use Program 1805 - Ring Assignments (page 551) to customize ringing. Extension...
Page 20
Initial System Startup 12Chapter 1: FeaturesDS1000/2000 Software Manual Initial Startup Programming Initial Startup Programming (Page 1 of 3) Step 1: Check the system defaults. • If you have a 4 slot Fixed Slot system, refer to DS2000 4 Slot Cabinet (with Fixed Slot Software) Hardware Configuration on page 6 • If you have a 4 slot U Slot system, refer to DS2000 4 Slot Cabinet (with U Slot Software) Hardware Configuration on page 6. • If you have an 8 slot U Slot system, refer to DS2000 8 Slot...