Page 11

 
DS2000 System Configuration 
DS1000/2000 Software Manual 
Chapter 1: Features  
  
3 
DS2000 System Configuration 
DS2000 Load Factor 
The total number of components you can install and connect to your DS2000 system depends on 
power supply capacity and the System Load Factor. Read the following notes, then turn to 
 
DS2000 
System Load Factor Calculations
 
 on page 4 to calculate the System Load Factor. 
Notes for Fixed Slot Software
 
• Fixed slot (01.nn.nn) software is only compatible with 4 slot...

Page 12

 
DS2000 System Configuration 
4 
 
Chapter 1: Features 
DS1000/2000 Software Manual 
DS2000 System Load Factor Calculations 
To check your system configuration: 
1. Indicate the quantity for each item installed in the  Qty
 
 column.
2. For each item, multiply the  
Qty
 
 times the  Load Factor
 
 and enter the value in the  Total Load
 
 
column.
3. Add all the values in the  
Total Load
 
 column and enter the value in  Item
 
  1
 
.
4. Determine the System Load Factor capacity of the power supplies...

Page 13

DS2000 System Configuration
DS1000/2000 Software ManualChapter 1: Features5
Examples of Typical DS2000 4-Slot Cabinet Maximum Configurations
Note that only the first configuration listed below (16 x 32) applies to Fixed Slot software. Refer to 
the Release Notes that came with your system to find out if you have Fixed Slot software.
16 x 32 (16 trunks and 32 digital extensions)
Recommended for sites with no Voice Mail and high trunk usage.
24 x 16 (24 trunks and 16 digital extensions)
Recommended for sites...

Page 14

DS2000 System Configuration
6Chapter 1: FeaturesDS1000/2000 Software Manual
32 x 32 x 16 (32 trunks, 32 digital extensions and 16 analog extensions)
Recommended for sites with Voice Mail, high trunk usage and high analog extension usage. 
This configuration requires 2 power supplies.
16 x 64 x 16 (16 trunks, 64 digital extensions and 16 analog extensions)
Recommended for sites with Voice Mail, normal to low trunk usage and low analog extension 
usage. This configuration requires 3 power supplies.
DS2000...

Page 15

DS2000 System Configuration
DS1000/2000 Software ManualChapter 1: Features7
Configuration 2 - with CPU P/N 80025A
For Software Versions 02.01.07 and Higher
Slot CN1 = 16DSTU PCB (extensions 300-315)
Slots CN2-CN8 = Undefined
Slots CN5-CN8 are not provided by the 4 slot cabinet hardware (i.e., cannot physically be 
installed)
The database provides the capability to program all 48 trunks and 96 extensions.
For Software Versions Prior to 02.01.07
Following is the default PCB configuration for a 4 slot...

Page 16

DS2000 System Configuration
8Chapter 1: FeaturesDS1000/2000 Software Manual
DS2000 8 Slot Cabinet (with U Slot Software) Hardware Configuration
For Software Versions 02.01.07 and Higher
Slot CN1 = 16DSTU PCB (extensions 300-315)
Slots CN2-CN8 = Undefined
The database provides the capability to program all 48 trunks and 96 extensions.
For Software Versions Prior to 02.01.07
Following is the default PCB configuration for an 8 slot cabinet with U Slot software prior to soft-
ware version 2.01.07. Note that...

Page 17

DS1000 System Configuration
DS1000/2000 Software ManualChapter 1: Features9
DS1000 System Configuration
DS1000 Load Factor
DS1000 System Load Factor Calculations
The combination of extensions, Digital Door Boxes and DSS Consoles you can connect to your 
system may be limited by the System Load Factor. Use the DS1000 System Load Factor Calcula-
tions chart below to verify your system’s configuration.
To check your system configuration:
1. Indicate the quantity for each item installed in the 
Qty column.
2....

Page 18

DS1000 System Configuration
10Chapter 1: FeaturesDS1000/2000 Software Manual
DS1000 Default Setup
Using the factory installed default configuration, your DS1000 system provides:
For more on installing the DS1000 Expansion PCB, refer to the DS1000 Quick Setup Guide (P/N 
80200QSET**) that came with your system.
Base Expansion Total
Trunks 3 3 6
Digital Extensions 8 8 16
Analog Extensions 4 4 8
Analog Door Boxes 1 1 2
Relays 1 1 2
Page Output 1 - 1
Music Input 1 - 1 

Page 19

Initial System Startup
DS1000/2000 Software ManualChapter 1: Features11
Initial System Startup
Default Feature Setup
DS2000 Fixed Slot Software (01.nn.nn)
All trunks are loop start DTMF
Use Program 1001 - Trunk Circuit Type (page 498) to change this assignment.
All extensions are 22-Button Display models.
Use Program 1801 - Extension Circuit Type (page 532) to change this assignment.
Trunks 1-8 ring on line keys 1-8.
Use Program 1805 - Ring Assignments (page 551) to customize ringing.
Extension...

Page 20

Initial System Startup
12Chapter 1: FeaturesDS1000/2000 Software Manual
Initial Startup Programming
Initial Startup Programming  (Page 1 of 3)
Step 1: Check the system defaults.
• If you have a 4 slot Fixed Slot system, refer to 
DS2000 4 Slot Cabinet (with Fixed Slot Software) 
Hardware Configuration on page 6
• If you have a 4 slot U Slot system, refer to 
DS2000 4 Slot Cabinet (with U Slot Software) 
Hardware Configuration on page 6.
• If you have an 8 slot U Slot system, refer to 
DS2000 8 Slot...