Page 41
Page 43 If there is a failure of one game PCB, fit the link cables as shown below to isolate the faulty unit and allow the other PCB(s) to operate correctly.
Page 42
Page 44 6. ADJUSTMENTS G GG G GAdjustment or maintenance on this machine should be carried out by qualified personnel only. D DD D DAufstellung, Service, Einstellung und Wartung dürfen nur von dafür qualifiziertem Fachpersonal durchgeführt werden. l ll l lJusteringer eller vedligehold af denne maskine bør kun udføres af kvalificeret personale. E EE E ELos ajustes y el mantenimiento de esta máquina deben ser realizados sólo por personal cualificado. F FF F FL’installation, le service, le réglage, ou la...
Page 43
Page 45 6-2 Adjustment Switches The Adjustment switches are located inside the coin door. 1. Service Switch. Press this switch to obtain game credits without incrementing the play meter. 2. Test Switch Slide the test switch ON to enter test mode. Test mode allows testing and the changing of game settings. (Refer to section 6-3 Test Mode page 46) 3. Select Up/Down Switch This switch is used to select the test required when in the Test Mode. 4. Enter Switch This switch is used to enter a selected test...
Page 44
Page 46 6-3 Test Mode 1. Open the coin door and slide the test switch “ON”. The “Menu Screen” will be displayed on the monitor. 2. Select the test required by using the select up/down switch. The colour of the selected test will change. 3. Activate the test by pressing the Enter switch. Select “EXIT” in each test to return to the “Menu Screen”. 4. After testing is completed, slide the test switch to the “OFF” position to return to normal game mode. The Test Switch must always be in the “OFF” position for...
Page 45
Page 47 6-3-1 Coin Options 1. Select “COIN OPTIONS” on the menu screen to set the game cost and related settings. The following screen is displayed. 2. Use the Select Up/Down switch to choose the required item then press the Enter button. 3. Use the Up/Down switch to change the setting. 4. Select “EXIT” and press the Enter button to return to the menu screen. Note:- The price of play on this machine is set within the Cashflow Coin Mech. Ensure that the Game Cost is set to 1 Coin 1 Credit. M E T INO I T P...
Page 46
Page 48 6-3-2 Game Options 1. Select “GAME OPTIONS” on the menu screen to set the game variables. The following screen is displayed. 2. Use the Select Up/Down switch to choose the required item then press the Enter button. 3. Use the Up/Down switch to change the setting. 4. Select “EXIT” and press the Enter button to return to the menu screen. M E T INO I T P I R C S E DTE S Y R O T C A F D I B C P ) a (4- 1 e l b a t t e s - - - - r e b m u n r e y a l p o t r e b m u n B C P s t e S2/ 1 t i a W y r t n...
Page 47
Page 49 6-3-3 I/O Test 1. Select “I/O TEST” on the menu screen to switches and lamps. The following screen is displayed. 2. Use the Select Up/Down switch to choose the required item then press the Enter button to enter the test. 3. Select “EXIT” and press the Enter button to return to the menu scr\ een. (a) Shows the condition of the DIP Switches on the PCB. In normal operation all switches are OFF. (If a switch is ON, it will be displayed in red.) (b) Shows the number of units linked. (1 ~ 4). If no...
Page 48
Page 50 6-3-3-1 I/O PCB Check 1. Select ‘I/O PCB CHECK’ from the I/O Test Screen. The followingscreen is displayed:- I/O TEST DIP 4 12345678 [ON:RED] LINKON 2 I/O PCB CHECK Master TX 3536 NAMCO LTD. DOWNHILL BIKERS ; Ver1.00 ; JPN 1/0 PCB CONNECT OK NAMCO LTD. ASCA-4 EXIT SELECT SW : CHOOSE ENTER SW : ENTER 6-3-3-2 How to [I/F Initialize] 1. Select ‘I/O PCB CHECK’ from the I/O Test Screen. The followingscreen is displayed:- Note: This is an instruction screen only . Initialization cannot be performed...
Page 49
Page 51 6-3-3-3 Switch Test 1. Select “Switch Test” on the I/O menu screen to test the switches. The following screen is displayed. 2. The display shows the current state of the switches. 3. Press the Up Select switch and the Enter switch together to EXIT and return to the I/O menu screen (a) Not Used (b) The display will change from OFF to ON as each switch is operated. (c) The game will return to normal play mode if this switch is turned off. (d to i) The display will change from OFF to ON as each...
Page 50
Page 52 6-3-3-4 Pedal & Lamp Test 1. Select ‘I/O PCB CHECK’ from the I/O Test Screen. The following screen is displayed:- I/O TEST DIP 4 12345678 [ON:RED] LINKON 2 PEDAL & LAMP TEST PEDAL BRAKE 01 2 3 4 OFF MIN >>> >>> MAX BUTTON LAMP ON ......................................................... (b) EXIT SELECT SW : CHOOSE ENTER SW : ENTER (a) (a) PEDAL BRAKE (force feedback) Press the ENTER button to apply the pedal brake force-feedback in five levels (0-4) (b) BUTTON LAMP The Start Switch lamp will...