Page 31

Electrical connection U.K.
All electrical work should be carried out
by a suitably qualified and competent
person in strict accordance with current
local and national safety regulations
(BS 7651 in the UK).
The appliance is supplied with a mains
cable and moulded plug ready for
connection to an a.c. single phase
220-240 V 50 Hz supply.
Please ensure that the connection data
quoted on the data plate match the
household mains supply.
Connection should be made via a
suitable switched socket which is easily...

Page 32

Do not place any appliance which
gives off heat, such as a toaster or
microwave oven, on top of this
appliance, as this would increase
the appliance’s energy consumption.
Location
The appliance should be installed in a
dry, well-ventilated room.
The room temperature should not go
above or below the climate range for
which the appliance is designed.
The higher the ambient temperature of
the room, the more energy the
appliance requires to operate.
It should not be installed where it is
exposed to direct...

Page 33

Installation
^Remove any cable clips from the
back of the appliance.
^Check that all parts at the back of the
appliance are unhindered. Carefully
remove any hindrance.
^Carefully push the appliance into
position. The appliance can be
placed directly against a wall.
Aligning the appliance
^To align the appliance adjust the feet
using the spanner supplied.
Installation
33
 

Page 34

The appliance is supplied right hand
hinged. If left hand door hinging is
required, follow the instructions below.
Removing the door handle:
First the side section of the handle must
be removed:
^Pull door handleatowards you. Side
sectionbslides back, creating a
gapdbetween side sectionband
mounting platec.
^
Place a suitable object (e.g. a spoon
handle) in gapd, and slowly lever
the handle towards the door.
Be careful not to let the spoon
handle slip, causing damage to the
appliance.
The side...

Page 35

^Open the appliance door, tilt it
downwards and take it off.
^Remove coverf, and unscrew hinge
bracketg.
^Fit hinge pinhin the second hole of
hinge bracketg.
^
Refit bracketiand coverjturned
through 180° on the opposite side.
^
Screw hinge bracketginto the
opposite side.
TheM4 screwhas to be screwed into
the left hole of the hinge bracket.
^
Turn coverfthrough 180°, and fit it
on the other side.
^
Remove spacerkwith a screwdriver
and refit it on the opposite side.
^
Remove pluglfrom the door
bearing bush...

Page 36

^Align the door with the appliance
housing using the long slot in hinge
platef. Then tighten screwc.
^Refit plinth fasciad, pushing it firmly
into position.
^With the door open, position covere
in the front of the plinth fascia, and
push it firmly into position.
Refitting the handle:
Please make sure you follow the
instructions below carefully when
you refit the handle. The door seal
will be damaged if the handle is
fitted incorrectly.
^
Loosely attach the handle to the
opposite side of the door with the...

Page 37

StayFresh zone compartments
^Pull the compartment right out by
taking hold of it at the back and lifting
it up to remove it.
^Pull the compartment lid forwardsa.
^Push the compartment lid in towards
the side that the appliance is going to
be opened from once the hinges
have been changed overb, and fit it
back on the runners.
^Push the lid in until it engagesc.
^
To put the compartment back in, pull
the runnersaright out and place the
compartment on top of the runners
close up against the door opening...

Page 38

600 mm wide appliancescan be
installed into a kitchen run. To match
the height of the rest of the kitchen, the
appliance can be fitted with a suitable
top boxa.
A ventilation gap of at least 50 mm
depth must be allowed for behind the
appliance and top box, if fitted, for air
to circulate.
A gap of at least 40 mm is required
between the top of the appliance (or
top box) and the ceiling to ensure that
air can circulate without hindrance.
Otherwise the appliance has to work
harder, resulting in an increase...

Page 39

39
 

Page 40

Alteration rights reserved / 5005
K 8967 S ed-1M.-Nr. 06 777 930 / 00
en-GB
 