Page 41
In the event of a fault which you cannot correct yourself please contact the Miele Technical Service Department. U1-800-999-1360 [email protected] V1-800-565-6435 [email protected] When contacting the Miele Technical Service Department, please quote the model and serial number of your appliance. These can be found on the data plate on the upper inside edge of the dishwasher door.Program update function - PC The Program Correction (PC) allows a technician to update the dishwasher to make use of new...
Page 42
To transport the dishwasher, e. g. when moving to a new home, note the following: –Empty the dishwasher. –Secure any loose parts, e. g. hoses, cables, cutlery baskets. –Transport the dishwasher in the upright position. If unavoidable it may be transported on its back. Do not transport it on its side or on the door. Residual water in the machine could leak and cause electrical damage. Transport 42
Page 43
User Maintenance Instructions To prevent accidents and machine damage, read these instructions beforeinstallation or use.
Page 44
Triple filter system The triple filter system in the base of the wash cabinet prevents food from being redeposited on dishes. It also protects the circulation pump from damage caused by foreign objects (e.g. broken glass, bones). The filter system should be cleaned every 4 - 6 months or whenever a foreign object is trapped. Cleaning the filter in the wash cabinet ^Turn off the dishwasher before cleaning. ^ Turn the handle counterclockwise to release the triple filter system.^Lift the filter out of the...
Page 45
To clean the underside of the filter, the flap must be opened: ^Pull back the yellow clip. ^Rinse all parts under running water. Scrub with a nylon brush if necessary. ^Close the flap so that the clip engages.^Return the filter so it lies flat in the base of the wash cabinet. ^Lock the filter by turning the handle clockwise. ,The dishwasher must not be used without the filter locked in place. 45
Page 46
Cleaning the spray arms Sometimes particles of food get stuck in the spray arm jets. The spray arms should be inspected and cleaned every 4 - 6 months. ^Turn off the dishwasher before cleaning. Remove the spray arms as follows: ^Remove the cutlery tray (if present). ^Press the top spray arm upwards to engage the inner ratchet and unscrew the spray arm. ^ Lift up the middle spray arm,a, to engage the ratchet and unscrew the spray arm,b.^Remove the lower basket. ^Pull the lower spray arm firmly upwards to...
Page 47
Cleaning the wash cabinet Generally, the wash cabinet is self cleaning if the correct amount of dishwasher detergent is used. The wash cabinet can be cleaned with a dishwasher cleaner such as Dis Cleaner available from your Miele dealer or the Miele Technical Service Department. Cleaning the door and door seal ^Wipe the door seal with a damp cloth to remove any food particles. ^Food residue and spilt liquids should be wiped from the sides of the dishwasher door. These are outside of the wash cabinet and...
Page 48
Cleaning the water inlet filter A filter is incorporated in the intake hose attached to the dishwasher’s shut off valve. If your water is hard, or the pipes contain sediment, this filter may clog and prevent enough water from entering the wash cabinet. Installing an in-line water filter ^If your water contains a large number of insoluble substances, a filter between the water valve and the intake hose connection is recommended. These filters can be purchased from Miele’s Technical Service Department.,The...
Page 49
Cleaning the drain pump and non-return valve If the dishwasher is not completely drained at the end of a program, the drain pump or non-return valve may be blocked. ^Turn off the dishwasher. ^Remove the triple filter (see Cleaning the filter in the wash cabinet). ^Use a jug or bowl to scoop water out of the wash cabinet. ^ Tilt the locking clamp to the side.^Pull out the non-return valve and rinse well under running water. The drain pump is beneath the non-return valve (see arrow). ^ Before returning the...