Page 21
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 17 79. A TN767 could not be hot-swapped with a cost-reduced TN2313 circuit pack when trunks were administered. “Conflict” would appear on the “list circuit-pack” display. Now, A TN767 with trunks can be hot-swapped with a TN2313, and vice versa. The correct TN code displays on the “list circuit-pack” screen. 80. If more than 65,535 ACD calls were...
Page 22
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 18 91. If the name of the TN802B node was changed, the board did not reboot to take the new name. 92.The “did-view” button (hospitality only) allowed changing an automatically assigned DID number but it did not allow removal of the DID number. 93. Two-line display terminals did not display 27 characters names with extensions. Now, the display shows...
Page 23
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 19 106. IP softphones in telecommuter or road warrior mode did not hear VOA announcements. 107. If an R6 or R7 system had TN2238 ATM boards translated, upgrading to a later release resulted in possible translation corruption. Now, only the TN2238 translation records are lost. 108. A problem in the Australian ISDN protocol caused incoming ISDN calls...
Page 24
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 20 121. If an endpoint and DEFINITY did not have matching codecs, a road warrior application call would hang for 15 seconds without a talk path, and then drop. Now, the call drops immediately. 122. When all circular hunt group members were busy, the next hunt group call caused a system reset. 123. It was previously possible to administer a TN802 as...
Page 25
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 21 134.International customers had no ability to change the handling of the “star” and “pound” digits by the “collect” vector step, so that the use of these digits to indicate “clear all collected digits” and “end-of-dialing” could be reversed. Some international mobile phone systems require this reversal, since their phone user normally enters a...
Page 26
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 22 146. Under certain circumstances, incoming DS1 trunk calls provided priority ringing, instead of following the coverage path. 147. Sometimes the TN802B board would not come up in the correct state without several reboots. Now, the TN802B application is run after as little as 2 reboots of the board. 148. When an incoming DID call into switch A...
Page 27
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 23 160. Calls routed over an ISDN trunk using Extended Trunk Access (ETA) was not considered when checking the numbering format field of the route patttern. 161.The command “list usage button crss-alrt” showed only stations that had a crisis alert button administered. Now, the command shows all administered crisis alert buttons in the system, both...
Page 28
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 24 175. If one of two or more TN802B boards in a system is disabled, it would remain out-of-service when re-enabled due to an incorrect alarm state. 176.The ‘list trace ewt’ command did not properly display data for columns Agents Working (AgtWk) and Agents Available (AgtAv). 177. When using the ‘list trace vdn’ command to trace a VDN/vector, which does...
Page 29
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 25 189.The ”Port Not Fnd” message is returned when doing a traceroute command to a CLAN board and a port was specified, but a bad location was used. 190. Attempting to add duplicate IP routes on a C-LAN board is now blocked. 191. The “Route Type” field on the ‘add ip-route’ form was administrable. Now, that field is not administrable. The route type is...
Page 30
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) Change Description 555-233-411 Issue 1 April 2000 Change Descriptions 26 205. PASTE data has been changed to include some missing Feature Access Codes (FACs) and button types for the Centre Vu (CV) Agent PC phone application. 206. Authorization codes of length 7 or less were not output in the Call Detail Recording & Reporting (CDR) repor t. 207. The default settings in the system-parameters maintenance form, page 3,...