Page 11

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Highlights 
7  
In Release 4.0 of the OMD Serenade Voicemail system, the connection between 
the Serenade and the PBX will be a QSIG ISDN link.  The Serenade will be able 
to interpret the QSIG MSI message and subsequent QSIG transfer information 
sent to it by DEFINITY, thus enabling QSIG Transfer to QSIG Voicemail to function 
between Serenade and DEFINITY, connected via QSIG...

Page 12

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Highlights 
8  
Networking — ATM
Asynchronous Transfer Mode (ATM) PNC Reliability
A DEFINITY system without duplicated Switch Processing Elements (SPEs) 
equipped for ATM Port Network Connectivity (PNC) is supported with duplicated 
Expansion Port Network (EPN) connectivity to different points on an ATM network.  
These points may be on separate ATM switches, the same ATM...

Page 13

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Highlights 
9  
Trouble Isolation: List Trace Command
Two new options for the list trace command allow customers and technicians to 
troubleshoot misdirected calls, trunking/routing problems, and call denials.
nlist trace station nnnnn (where nnnnn is the number of the station you 
want to troubleshoot)
nlist trace tac xxxx (where xxxx is the identifier of the trunk you want to...

Page 14

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Highlights 
10   

Page 15

Change Descriptions 
11  
DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Change Descriptions
The following problems have been addressed and corrected in DEFINITY Enterprise 
Communications Server (ECS), Release 8, Issue 2.0 (02.0.034.2).
1. User defined data associated with the auto-selection of DIDs displayed as 
asterisks in the Property Management System (PMS).
2. If the Survivable Remote Processor was not in contact with...

Page 16

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Change Descriptions 
12  
7. Processor channels could remain down after reset system 2 in some 
cases. Now, processor channels come back up in these cases. 
8.A rotary station user can now simulate flash hook by dialing the digit that’s 
specified in the new feature parameters field, if this functionality has been 
enabled by setting the new Recall Rotary Digit field on the...

Page 17

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Change Descriptions 
13  
22. Q.931 calls failed after a few dozen calls.
23.After entering “busyout pnc-standby”, control was returned to the SAT 
before the process was complete. If the SAT entered another command, 
new inter-port calls could not be made for up to one minute. Now, the SAT 
forces the user to wait for the entire board test/release to complete before 
gaining...

Page 18

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Change Descriptions 
14  
37. The IP Solutions endpoint did not have the current button and lamp status 
upon registration.
38. Attempting to register an IP Solutions endpoint from an extension with a 
data module corrupted the extension’s translation. Now, the registration is 
denied.
39. An extension with a large number of autodial buttons could not register as a 
DoLAN...

Page 19

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Change Descriptions 
15  
51. The wakeup display mode did not timeout. Now, the wakeup mode 
undergoes timeout after 1 minute.
52. Abandoned calls to telecommuter application endpoints left the associated 
endpoint ringing.
53. If the system is optioned as V7, and the CLAN board is pulled, the trunk 
groups remained in service. Now, the trunk groups are taken out-of-service...

Page 20

DEFINITY Enterprise Communication Server Release 8, Issue 2.0 (02.0.034.2) 
Change Description  555-233-411  Issue 1
April 2000
Change Descriptions 
16  
64. When a telecommuter application attempted to use Trunk Access Code 
(TAC) dialing to establish the service link audio call, the attempt failed if 
more than 8 digits were needed after the TAC. Now, all digits after the TAC 
are sent correctly.
65. During the PMS database swap routine, the switch was performing resets.
66. The Leave Word Calling...