Page 21
Administration What’s New: Network Call Redirection 15 DEFINITY administration overview 0 The following fields must be set on the DEFINITY administration forms for NCR to work: Form Field Value For both NCT and NCD System Parameters Customer OptionsCall Center Release8.3 or later System Parameters Customer OptionsISDN Network Call RedirectionY Best Service Routing Application form (for the location to receive the call)Net Redir? Y For NCT Trunk Group formGroup Type Supplementary Services...
Page 22
Administration 16 DEFINITY® ECS R8.3 What’s New: Network Call Redirection The ~r command takes up two digit positions in the vector step. This works with queue-to-best or check-best vector steps. No change to the vector steps is required for NCR with BSR . Trunk Group form 0 For Network Call Transfer, the Group Type field on the Trunk Group form must be set to isdn and the Network Call Redirection field must be set to transfer . The Supplementary Service Protocol field must be set to g and...
Page 23
Administration What’s New: Network Call Redirection 17 Supplementary Service Protocol: NCT: Network Call Redirection: for NCT: For NCD, the Supplementary Service Protocol field must be set to c and the Network Call Redirection field must be set to deflect . Refer to the following figures: GLERKIXVYROKVSYT4EKISJ 8692/+6394 +VSYT2YQFIV+VSYT8]TIMWHR(66ITSVXW]...
Page 24
Administration 18 DEFINITY® ECS R8.3 What’s New: Network Call Redirection Supplementary Services field: for NCD: Network Call Transfer field: for NCD: GLERKIXVYROKVSYT4EKISJ 8692/+6394 +VSYT2YQFIV+VSYT8]TIMWHR(66ITSVXW] +VSYT2EQI&836828% (MVIGXMSRX[S[E]3YXKSMRK(MWTPE]#]...
Page 25
Administration What’s New: Network Call Redirection 19 Signaling Group form 0 For NCT, the Network Call Transfer field on the Signaling Group form must be set to Y . Refer to the following figure: For NCD, the Network Call Transfer field on the Signaling Group form must be set to N . Refer to the following figure: GLERKIWMKREPMRKKVSYT4EKISJ 7-+2%0-2++6394 +VSYT2YQFIV...
Page 26
Administration 20 DEFINITY® ECS R8.3 What’s New: Network Call Redirection Best Service Routing Application form 0 On the DEFINITY Best Service Routing Application form, the Net Redir? field must be set to Y for each location to which calls are to be directed using NCR. Refer to the following figure. The number administered in the interflow VDN field on the Best Service Routing form (or in the ~r vector step on the Call Vector form) should not have any ARS prefix or trunk access code. Some PSTN...
Page 27
Administration What’s New: Network Call Redirection 21 Call Vector form0For non-BSR applications or for standard or enhanced Lookahead Interflow applications replaced by NCR, supplementing BSR applications, on the DEFINITY Call Vector form, the leftmost position in the route-to vector step (vector step 2 in the example on the next page) must be set to ~r for each vector that will invoke NCR. The number administered in the ~r vector step on the Call Vector form should not have any ARS prefix or...
Page 28
Troubleshooting and Things to Know 22 DEFINITY® ECS R8.3 What’s New: Network Call Redirection Troubleshooting and Things to Know0 Overview0This section contains basic information on troubleshooting, as well as important information about administering NCR. Troubleshooting0General troubleshooting of NCR can be accomplished by using: •the ISDN message trace information provided by the Message Sequence Tool (MST) •Vector events displayed by the display events DEFINITY system administration command. •To...
Page 29
Troubleshooting and Things to Know What’s New: Network Call Redirection 23 NCR troubleshooting 0 If NCR vector activation fails, use the display events switch administration terminal command to check for the following NCR vector events: •NCR: Invoke trunk not ISDN •NCR: Bad NCR trunk admin •NCR: No NCT PSTN service •NCR: No NCT outgoing trk •NCR: NCT outgo trk drop •NCR: PSTN NCT invoke err •NCR: PSTN NCT netwrk err •NCR: Used NCT trk-to-trk •NCR: No NCD PSTN service •NCR: NCD invalid PSTN nmbr •NCR:...
Page 30
Troubleshooting and Things to Know 24 DEFINITY® ECS R8.3 What’s New: Network Call Redirection Things to know0The following important items should be known. Failures0Failures can occur in NCR after the queue-to-best vector command is executed. Vector steps are not used to log vector events (this happens automatically), so vector steps following the queue-to-best command are needed to provide alternate call treatments. To prepare for this, use one of the following: •If the second leg of the call...