    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.3 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Administration
    What’s New: Network Call Redirection 15
    DEFINITY 
    administration 
    overview
    0
    The following fields must be set on the DEFINITY administration forms 
    for NCR to work:
    Form Field Value
    For both NCT and NCD
    System Parameters 
    Customer OptionsCall Center 
    Release8.3 or later
    System Parameters 
    Customer OptionsISDN Network 
    Call 
    RedirectionY
    Best Service Routing 
    Application form (for the 
    location to receive the 
    call)Net Redir?
    Y
    For NCT
    Trunk Group formGroup Type
    Supplementary 
    Services 
    Protocol 
    Network Call 
    Redirectionisdn
    g
    Nortel-transfer (for 
    MCI DMS250 
    switches)
    Signaling Group formNetwork Call 
    TransferY 
    						
    							Administration
    16 DEFINITY® ECS R8.3 What’s New: Network Call Redirection
    The ~r command takes up two digit positions in the vector step. This 
    works with queue-to-best
     or check-best
     vector steps. No change to 
    the vector steps is required for NCR with BSR
    .
    Trunk Group 
    form
    0
    For Network Call Transfer, the Group Type
     field on the Trunk Group 
    form must be set to isdn
     and the Network Call Redirection
     field 
    must be set to transfer
    . The Supplementary Service Protocol
     
    field must be set to g
     and the Network Call Redirection
     field must 
    be set to Nortel-transfer
     for MCI DMS250 switches. If the NCT 
    feature is subscribed to for the DEFINITY NCR feature, only PRI ISDN 2-
    way trunks may be used for the incoming-call trunk groups to be 
    administered for vectoring activation of NCT, since the software selects a 
    trunk from the same trunk group to set up the second leg call. Refer to 
    the following figures:For NCD
    Trunk Group FormGroup Type
    Supplementary 
    Services 
    Protocol 
    Network Call 
    Redirectionisdn
    c
    deflect
    Signaling Group FormNetwork Call 
    TransferN
    For non-BSR applications or for standard or enhanced Lookahead 
    Interflow applications replaced by NCR supplementing 
    BSR applications
    Call Vector form leftmost position in 
    the route-to 
    number
     vector step~r for each vector 
    that will invoke 
    NCR.  Form Field Value 
    						
    							Administration
    What’s New: Network Call Redirection 17
    Supplementary Service Protocol: NCT:
    Network Call Redirection: for NCT:
    For NCD, the Supplementary Service Protocol
     field must be set 
    to c
     and the Network Call Redirection
     field must be set to 
    deflect
    . Refer to the following figures:
    GLERKIXVYROKVSYT4EKISJ
    8692/+6394
    +VSYT2YQFIV+VSYT8]TIMWHR(66ITSVXW]
    +VSYT2EQI1-36828%
    (MVIGXMSRX[S[E]3YXKSMRK(MWTPE]#]
    (MEP%GGIWW#R&YW]8LVIWLSPH2MKLX7IVZMGI
    5YIYI0IRKXL
    7IVZMGI8]TIWHR%YXLSHI#R8IWXEPP-8VIWX
    *EV)RH8IWX0MRI2S
    8IWXEPP&
    8692/4%6%1)8)67
    SHIWIXXS7IRH(MWTPE]SHIWIXXS7IRH2EXMSREP-)W
    1E\1IWWEKI7M^IXS7IRHLEVKI%HZMGIRSRI
    7YTTPIQIRXEV]7IVZMGI4VSXSGSP
    K(MKMX,ERHPMRKMRSYXIRFPSGIRFPSG
    8VYRO,YRXHIWGIRH
    (MKMXEP0SWW+VSYT
    EPPMRK2YQFIV(IPIXI-RWIVX2YQFIVMRK*SVQEX
    &MX6EXI7]RGLVSRM^EXMSREW]RG(YTPI\JYPP
    (MWGSRRIGX7YTIVZMWMSR-R#]3YX#]
    %RW[IV7YTIVZMWMSR8MQISYX 
    						
    							Administration
    18 DEFINITY® ECS R8.3 What’s New: Network Call Redirection
    Supplementary Services field: for NCD:
    Network Call Transfer field: for NCD:
    GLERKIXVYROKVSYT4EKISJ
    8692/+6394
    +VSYT2YQFIV+VSYT8]TIMWHR(66ITSVXW]
    +VSYT2EQI&836828%
    (MVIGXMSRX[S[E]3YXKSMRK(MWTPE]#]
    (MEP%GGIWW#R&YW]8LVIWLSPH2MKLX7IVZMGI
    5YIYI0IRKXL
    7IVZMGI8]TIWHR%YXLSHI#R8IWXEPP-8VIWX
    *EV)RH8IWX0MRI2S
    8IWXEPP&
    8692/4%6%1)8)67
    SHIWIXXS7IRH(MWTPE]SHIWIXXS7IRH2EXMSREP-)W
    1E\1IWWEKI7M^IXS7IRHLEVKI%HZMGIRSRI
    7YTTPIQIRXEV]7IVZMGI4VSXSGSP
    G(MKMX,ERHPMRKMRSYXIRFPSGIRFPSG
    8VYRO,YRXHIWGIRH
    (MKMXEP0SWW+VSYT
    EPPMRK2YQFIV(IPIXI-RWIVX2YQFIVMRK*SVQEX
    &MX6EXI7]RGLVSRM^EXMSREW]RG(YTPI\JYPP
    (MWGSRRIGX7YTIVZMWMSR-R#]3YX#]
    %RW[IV7YTIVZMWMSR8MQISYX
    GLERKIXVYROKVSYT4EKISJ
    8692/*)%896)7
    %%%WWMKRQIRX#R1IEWYVIHFSXL;MHIFERH7YTTSVX#R
    1EMRXIRERGI8IWXW#]
    (EXE6IWXVMGXMSR#R2%878VYRO1IQFIV
    7IRH2EQIR7IRHEPPMRK2YQFIVR
    9WIHJSV(7#R
    7YTTVIWW3YXTYPWMRK#R
    3YXKSMRKLERRIP-()RGSHMRKTVIJIVVIH99--)8VIEXQIRXWLEVIH
    1E\MQYQ7M^ISJ99--)SRXIRXW
    6ITPEGI6IWXVMGXIH2YQFIVW#R
    6ITPEGI9REZEMPEFPI2YQFIVW#R
    7IRHSRRIGXIH2YQFIVR
    2IX[SVOEPP6IHMVIGXMSR
    HIJPIGX
    7IRH9-(#]&766ITP]FIWX(-7EYWI:EPYI
    7IRHSHIWIX0%--)#R
    2IX[SVO.ETER2IIHWSRRIGX&IJSVI(MWGSRRIGX#2 
    						
    							Administration
    What’s New: Network Call Redirection 19
    Signaling Group 
    form
    0
    For NCT, the Network Call Transfer
     field on the Signaling Group 
    form must be set to Y
    . Refer to the following figure:
    For NCD, the Network Call Transfer
     field on the Signaling Group 
    form must be set to N
    . Refer to the following figure:
    GLERKIWMKREPMRKKVSYT4EKISJ
    7-+2%0-2++6394
    +VSYT2YQFIV
    %WWSGMEXIH7MKREPMRK#]1E\RYQFIVSJ2%87
    4VMQEV](LERRIP&1E\RYQFIVSJ%87
    8VYRO+VSYTJSV2%87
    8VYRO+VSYTJSVLERRIP7IPIGXMSR
    7YTTPIQIRXEV]7IVZMGI4VSXSGSPE2IX[SVOEPP8VERWJIV#
    ]
    GLERKIWMKREPMRKKVSYT4EKISJ
    7-+2%0-2++6394
    +VSYT2YQFIV
    %WWSGMEXIH7MKREPMRK#]1E\RYQFIVSJ2%87
    4VMQEV](LERRIP&1E\RYQFIVSJ%87
    8VYRO+VSYTJSV2%87
    8VYRO+VSYTJSVLERRIP7IPIGXMSR
    7YTTPIQIRXEV]7IVZMGI4VSXSGSPE2IX[SVOEPP8VERWJIV#
    R 
    						
    							Administration
    20 DEFINITY® ECS R8.3 What’s New: Network Call Redirection
    Best Service 
    Routing 
    Application form
    0
    On the DEFINITY Best Service Routing Application form, the Net 
    Redir?
     field must be set to Y
     for each location to which calls are to be 
    directed using NCR. Refer to the following figure.
    The number administered in the interflow VDN field on the Best Service 
    Routing form (or in the ~r vector step on the Call Vector form) should 
    not 
    have any ARS prefix or trunk access code. Some PSTN numbers will 
    need to include the long-distance access code. Contact your PSTN for 
    specific information.
    !CAUTION:
        BEST SERVICE ROUTING APPLICATION
     Number: 1     Name: ARS               Maximum Suppression Time: 30   Lock? n
    Num  Location Name    Switch Node  Status Poll VDN  Interflow VDN    Net Redir?
    1                                  95022011          3035389425 y
    2                                  95022111          3038053652 y
    3                                  95032211          95032221 n
    3035551222
    3035551111 
    						
    							Administration
    What’s New: Network Call Redirection 21
    Call Vector form0For non-BSR applications or for standard or enhanced Lookahead 
    Interflow applications replaced by NCR, supplementing BSR 
    applications, on the 
    DEFINITY Call Vector form, the leftmost position in 
    the route-to
     vector step (vector step 2 in the example on the next 
    page) must be set to ~r
     for each vector that will invoke NCR.
    The number administered in the ~r vector step on the Call Vector form 
    should 
    not have any ARS prefix or trunk access code. Refer to the 
    following figure.
    !CAUTION:
    CALL VECTOR                                 \
     Number: 37                   Name _Reroute using NCR_Feature_         Lock? n
         Basic? y   EAS? y   G3V4 Enhanced? y   ANI/II-Digits? y   ASAI Routing? y
     Prompting? y   LAI? y  G3V4 Adv Route? y           CINFO? n            BSR? y
    01 wait         0    
     secs hearing ringback02 route-to     number ~r3035385103___
    03                                                         
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    ~r3035551222  
    						
    							Troubleshooting and Things to Know
    22 DEFINITY® ECS R8.3 What’s New: Network Call Redirection
    Troubleshooting and Things to Know0
    Overview0This section contains basic information on troubleshooting, as well as 
    important information about administering NCR.
    Troubleshooting0General troubleshooting of NCR can be accomplished by using:
    •the ISDN message trace information provided by the Message 
    Sequence Tool (MST)
    •Vector events displayed by the display events DEFINITY 
    system administration command.
    •To see the behavior of a particular VDN or vector, use the list 
    trace vdn and/or list trace vector commands to check for 
    NCR errors.
    •To check for NCR errors using BSR processing, enter the ch MST 
    switch administration terminal command to set the BSR and vector 
    fields to Y, and use the enable mst and the list mist cont 
    switch administration terminal commands to see NCR-related MST 
    trace data.
    •To see NCR-related BSR peg counts, enter the go tcm switch 
    administration terminal command or enter the rdd :dpm_mgr 
    Bsr_appl_loc command to see NCR-related BSR attempts, 
    int errors, net errors, redirs, and discs peg counts. 
    						
    							Troubleshooting and Things to Know
    What’s New: Network Call Redirection 23
    NCR 
    troubleshooting
    0
    If NCR vector activation fails, use the display events
     switch 
    administration terminal command to check for the following NCR vector 
    events:
    •NCR: Invoke trunk not ISDN
    •NCR: Bad NCR trunk admin
    •NCR: No NCT PSTN service
    •NCR: No NCT outgoing trk
    •NCR: NCT outgo trk drop
    •NCR: PSTN NCT invoke err
    •NCR: PSTN NCT netwrk err
    •NCR: Used NCT trk-to-trk
    •NCR: No NCD PSTN service
    •NCR: NCD invalid PSTN nmbr
    •NCR: NCD call connect err
    •NCR: PSTN NCD invoke err
    •NCR: PSTN NCD netwrk err
    •NCR: PSTN NCD max redirs
    •NCR: PSTN NCD no disc
    •NCR: Internal system err 
    						
    							Troubleshooting and Things to Know
    24 DEFINITY® ECS R8.3 What’s New: Network Call Redirection
    Things to know0The following important items should be known.
    Failures0Failures can occur in NCR after the queue-to-best
     vector command is 
    executed. Vector steps are not used to log vector events (this happens 
    automatically), so vector steps following the queue-to-best
     command 
    are needed to provide alternate call treatments. To prepare for this, use 
    one of the following:
    •If the second leg of the call cannot be set up, use the second 
    vector step to log the event that caused this. Administer the 
    second vector step to anticipate this problem by administering it to 
    record call failure events.
    •Try to invoke Network Call Transfer. If Network Call Transfer is 
    invoked and the public network rejects the call, the call should revert 
    to a trunk-to-trunk transfer. In this case, the call is not lost.
    NCT0With NCT, the transferring vector may or may not answer the first leg of 
    the call before redirecting the call over the public network. The vector can 
    set up the second leg of the call before answering the first leg, but the 
    public network cannot redirect the call until the first leg is answered. If the 
    call has not been answered, DEFINITY will answer the call before 
    requesting NCT.
    NCD0With NCD, no steps in the vector can answer the call when it is being 
    redirected, or the redirection will not occur. In other words, vector steps 
    must not answer the call before requesting NCR.
    Current offerings for NCD will not “clear the call on alerting.” 
    Announcement 
    Vector Steps
    0
    At this time, announcement vector steps cannot be used with NCD before 
    NCD is to be invoked. Announcement vector steps can be used in 
    following vector steps if NCD fails. Announcement vector steps can be 
    used with NCT. 
    						