Multicarrier G2 Universal Module to R8r EPN 
5-23 Standard Reliability 
5
Unpack and Inspect Expansion Control Carrier
1. Insp ec t the new J58890AF Exp ansion Control Carrier for any d amag e. 
Also verify that the b ac kp lane p ins are not b ent.
2. Plac e the exp ansion c ontrol c arrier on the floor so that the rear of the 
carrier faces up.
3.Install the CFY1 c urrent limiter (CURL)...

Page 172

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-24 Standard Reliability 
5
Figure 5-4. TDM/LAN Connections for Standard Reliability Release 8 EPN Figure Notes
1.Port Carrier (“ C” Position)
2. ZAHF4 TDM/LAN Terminator
3. TDM/LAN Cab le (WP91716 L6)
4. Mod ule Control Carrier (“ A”  Position)
5. Port Carrier (“ D” Position)6 . Po r t  C a rr i e r  ( “ E”  Po si t io n )
7. Slot 21
8. Slot...

Page 173

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-25 Standard Reliability 
5
9. On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or TDM terminator to 
Slot 02. On p ort c arriers J58890BB-2 and  J58890BB-3, c onnec t the TDM 
c ab les to Slot 01.
10.Install the front trim p late on the “ A”  c arrier. Install the fan trim plate.
11. Install the p ower units (removed  from G2 universal...

Page 174

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-26 Standard Reliability 
5
Install Circuit Packs
1. Install the new Release 8 control c irc uit p ac ks into c arrier “ A.”  Use the 
new lab el and  the annotated  “ list c onfig uration all”  (p rovid ed  with the 
Release 8 removable med ia) as a g uid e.
NOTE:
Currently, the TN768 Tone-Cloc k c irc uit p ac k resid es in a p ort slot of...

Page 175

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-27 Standard Reliability 
5
Collocated Port Networks
For a stand ard reliab ility system with 1 c olloc ated  EPN, use 1 fib er op tic  c ab le 
and  2 lig htwave transc eivers to d irec tly c onnec t the networks.
For a stand ard  reliab ility system with 2 c olloc ated  EPNs, use 3 fiber optic  c ab les 
and  6 lig htwave transc eivers to d...

Page 176

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-28 Standard Reliability 
5
For Either 1 or 2 Collocated Expansion Port Networks
1. Behind  c ontrol c arrier A of PPN c ab inet 1 (see Figure 5-5, Figure 5-6, and  
Figure 5-7
):
nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transc...

Page 177

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-29 Standard Reliability 
5
For Two Collocated Expansion Port Networks
1. Behind control carrier A of PPN c abinet 1:
nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 1A02.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transc eiver
nConnec t 1 end  of the fib er optic  c ab le to the lightwave...

Page 178

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-30 Standard Reliability 
5
4. Behind control carrier A of EPN c abinet 3:
nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 3A02.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transc eiver
nConnec t the other end  of the fiber op tic  c able to the lig htwave 
transc eiver, just installed , at...

Page 179

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-31 Standard Reliability 
5
Figure 5-6. Fiber Optic Connections PPN to EPN1
Figure 5-7. Collocated Fiber Optic Connections PPN to EPN2 Figure Notes
1. Lightwave Transc eiver
2. To PPN Carrier A Slot 1A01
3. To EPN 1 Carrier A Slot 2A014. Fiber Optic Cable
5. TX Connec tor
6. RX Connec tor
Figure Notes
1. Lightwave Transc eiver
2. To PPN...

Page 180

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-32 Standard Reliability 
5
Figure 5-8. Collocated Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At c ontrol c arrier A of PPN c ab inet 1. See Figure 5-5 throug h Figure 5-9.
nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 1A01.
NOTE: