Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 6 Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 6 Instructions Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 6 Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 281

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-7 Contention Between Simultaneous Commands 
8
Contention Between Simultaneous 
Commands
The following limits apply to simultaneous maintenance and administration 
activities:
nUp to 8 users can be logged into the system at the same time.
nUp to 5 maintenance commands can run concurrently. ResultOne of the following results:
PASS: The command successfully...

Page 282

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-8 Busyout and Release Commands 
8
nUp to 3 maintenance commands issued from system access port (SAP) or 
EPN Maintenance circuit pack logins can run concurrently. The other 2 are 
reserved for the SYSAM and INADS ports.
nUp to 5 administration commands can run concurrently.
nIn general, a maintenance object or other system entity can be acted upon 
by only...

Page 283

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-9 Busyout and Release Commands 
8
tests require that the object be released to complete. A WARNING alarm with 
error type 18 is logged against each busied out object. All busied out MOs can 
be displayed by entering error type 18 in the Error Type field on the Hardware 
Errors Report Form (see display errors). The matching release command 
returns the...

Page 284

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-10 Common Abort and Fail Codes 
8
Common Abort and Fail Codes
Table 8-3 lists common error codes associated with abort and fail results for 
busyout, release, test, and reset commands. In addition to these, many 
maintenance objects have other unique error codes.
Table 8-3. Common Error Codes for Busyout, Release, Test, 
and Reset Commands 
Error...

Page 285

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-11 Common Abort and Fail Codes 
8
1338 ABORT The system could not execute the command on a component on 
the Standby SPE because an interchange was pending. 
1. Refer to ‘‘
STBY-SPE (Standby SPE Maintenance)’’ in Chapter 
9.
2. Try the command again after the SPE interchange occurs.
1339 ABORT The system could not execute the command on a component on 
the...

Page 286

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-12 Common Abort and Fail Codes 
8
62524 
62525 
62526ABORT Maintenance is currently active on the maximum number of 
maintenance objects that the system can support. This condition 
is commonly caused by the fact that the system contains a large 
number of stations or trunks that have been administered, and 
whose circuit packs are installed, but which are...

Page 287

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-13 Alarm and Error Categories 
8
Alarm and Error Categories
The display alarms and display errors commands allow you to generate 
reports for certain groups of maintenance objects. By entering a category from 
the Table 8-4
 into the Category field of the input form, you can restrict the report 
to only those maintenance objects included in that category....

Page 288

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-14 Alarm and Error Categories 
8
detectorDTMR-PT
DETR-BD
GPTD-PT
TONE-BD
dup-speCARR-POW
DUPINT
MEM-BD
PROCR
SPE-SELEC
STBY-SPE
SW-CTL
TAPE
environAC-POWER
CABINET
CARR-POW
DC-POWER
EMG-XFER
EXT-DEV
POWER
RING-GEN
exp-intfAC-POWER
CARR-POW
DC-POWER
DUPINT
EPN-SNTY
EXP-INTF
MAINT
SYNC
Table 8-4. Alarm and Error Categories  — Continued
Category Maintenance...

Page 289

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-15 Alarm and Error Categories 
8
TDM-CLK
TONE-BD
ext-devCUST-ALM
generatrSTRAT-3
SYNC
TDM-CLK
TONE-PT
TONE-BD
inads-linkINADS
infcEXP-INTF
ISDN-LNK
ISDN-SGRP
PGATE-BD
X25-PT
maintMAINT
mass-stDISK
H-ADAPTR
STO-DATA
TAPE
mbusDUPINT
MEM-BD
PROCR
SW-CTL
TAPE
memoryMEM-BD
Table 8-4. Alarm and Error Categories  — Continued
Category Maintenance Objects
Continued...

Page 290

DEFINITY Enterprise Communications Server Release 6
Maintenance for R6r Volumes 1 & 2  555-230-126  Issue 2
January 1998
Maintenance Commands 
Page 8-16 Alarm and Error Categories 
8
miscCONFIG
ERR-LOG
MIS
PROC-SAN
SYSTEM
TIME-DAY
mmiMMI-BD
MMI-LEV
MMI--PT
MMI-SYNC
mnt-testM/T-ANL
M/T-BD
M/T-DIG
M/T-PKT
modemMODEM-BD
MODEM-PT
mssnetH-ADAPTR
SW-CTL
netconSW-CTL
pktM/T-PKT
PKT-BUS
pms/jrnlJNL-PRNT
PMS-LINK
pncDS1C-BD
DS1-FAC
EXP-INTF
FIBER-LK
PNC-DUP
Table 8-4. Alarm and Error Categories  — Continued...