DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-45 Automatic Transmission Measurement System (ATMS) 6 processing, the test aborts. When the trunk is already being tested by maintenance software, the test is queued and run when the maintenance activity finishes. Measurement data gathered by analog testcalls can be retrieved with the list testcalls command which is described below. Which...
Page 252
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-46 Automatic Transmission Measurement System (ATMS) 6 ATMS Reports (List Testcall Command) The list testcalls command produces detailed and summary reports of measurements made by the Automatic Transmission Measurement System (ATMS). Measurement reports contain data on trunk signal loss, noise, singing return loss, and echo return loss, and...
Page 253
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-47 Automatic Transmission Measurement System (ATMS) 6 Input Parameters - List Testcall Command ATMS Summary Reports The ATMS Summary Report summarizes, on a trunk group basis, the collective results of the latest ATMS tests performed on each trunk group. By interacting with the trunk group form, it highlights out-of-tolerance measurements....
Page 254
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-48 Automatic Transmission Measurement System (ATMS) 6 Screen 6-2. Summary Report Screen Output Fields - ATMS Summary Report Trk Grp Num Results for each trunk group are listed by trunk group number. Trunk group number Only outgoing or two-way analog trunks are listed. Num Of Trks The number of members in the trunk group. Last Test Date The...
Page 255
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-49 Automatic Transmission Measurement System (ATMS) 6 ATMS Detail Report This report is divided into two sections. The upper section lists the trunk group, trunk type, trunk vendor, TTL type, and the user-defined threshold values administered on page 4 of the trunk group form. The lower section lists the most recent set of measurements for...
Page 256
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-50 Automatic Transmission Measurement System (ATMS) 6 TTL Type The type of terminating test line on the switch at the far end of the trunk to which the test call was made. Threshold Values The list of marginal and unacceptable threshold values for each type of measurement. These are defined on the trunk group form. Trk Mem The trunk member...
Page 257
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-51 Automatic Transmission Measurement System (ATMS) 6 ATMS Measurement Analysis ATMS compares the results of the test measurements with threshold values to identify trunks that are out of tolerance or unusable. Once a defective circuit has been pinpointed, a proper analysis must be made to determine the appropriate action to take on the...
Page 258
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Additional Maintenance Procedures Page 6-52 Automatic Transmission Measurement System (ATMS) 6
Page 259
LED Indicators Page 7-1 Terminal Alarm Notification 7 DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 7 7LED Indicators If a maintenance object in the system begins to fail some of the periodic tests, the system automatically generates an alarm. This alarm indicates to maintenance personnel that action is required to restore the system to a normal condition. The system identifies three levels of alarms: nMajor Alarms — Failures...
Page 260
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-2 Attendant Console LEDs 7 button associated with the lighted alarm lamp. If the lamp is turned off, and the alarm has not been resolved by the time maintenance reschedules testing, the green status LED will resume its steady state. The following alarms are displayed: Attendant Console LEDs The console has two red LEDs, labeled “ALM” and “ACK.” The ALM LED...