Page 261
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-3 Circuit Pack LEDs 7 Circuit Pack LEDs Each circuit pack typically has three LEDs on the front panel visible at the front of the carrier, there are some exceptions to this (for example DS1CONV circuit pack) that are covered later in this section. On most circuit packs, the LEDs indicate the following when lit. Exceptions to these indications are explained in...
Page 262
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-4 Expansion Interface Circuit Pack LEDs 7 nMisconnected optical fiber cables may cause several circuit packs to alarm. nPacket bus faults can cause several port circuit packs to display red LEDs. If a circuit pack has had at least five minutes to be initialized, and the red LED is lit without an associated alarm in the Alarm Log, the circuit pack may not be...
Page 263
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-5 Maintenance Circuit Pack LEDs 7 The yellow LED displays various flashing patterns to provide status information useful in isolating faults in the fiber link and other components connected to the fiber link. Table 7-1 illustrates the EI yellow LED states. Maintenance Circuit Pack LEDs TN1648 System Access-Maintenance (SYSAM) and TN775 EPN Maintenance...
Page 264
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-6 Maintenance Circuit Pack LEDs 7 Only those on the active SYSAM are updated with the current system status. The yellow LED that is third from the top indicates which SYSAM is active. These LEDS are illustrated on the following page.MAJOR (red) flashing Major Alarm against a component in the same cabinet, (PPN for SYSAM, and EPN for MAINT). MAJOR (red) solid...
Page 265
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-7 Duplication Interface Circuit Pack LEDs 7 Figure 7-1. SYSAM and EPN Maintenance Circuit Pack LEDs Duplication Interface Circuit Pack LEDs In systems with duplicated SPEs, (High Reliability and Critical Reliability), there are two Duplication Interface UN330B circuit packs. One is located in carrier A and one in carrier B of the PPN. Each circuit pack has...
Page 266
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-8 Switch Node Interface LEDs 7 Figure 7-2. Duplication Interface Circuit Pack LEDs Switch Node Interface LEDs The Switch Node Interface (SNI) TN573 circuit pack has the standard red, green, and yellow LEDs. The red and green LEDs have the traditional meaning, where red indicates an alarm condition, and green indicates testing in progress. The yellow LED...
Page 267
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-9 DS1 CONV (TN574/TN1654) Circuit Pack LEDs 7 DS1 CONV (TN574/TN1654) Circuit Pack LEDs The TN574 and the TN1654 LEDs provide an indication of the state of the DS1 Converter and facilities, and are covered in the following sections of this document. TN574 Circuit Pack LEDs Seven LEDs provide an indication of the state of the DS1 Converter (DS1 CONV) TN574...
Page 268
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-10 DS1 CONV (TN574/TN1654) Circuit Pack LEDs 7 The yellow LED is used to indicate the state of the Fiber Interface, the Fiber Channel, and the DS1 channel in the following manner and order of priority. DS1 Facility LEDs Below the three standard LEDs on the DS1C circuit pack are four green LEDs used to indicate whether a receive signal is present for each of...
Page 269
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-11 DS1 CONV (TN574/TN1654) Circuit Pack LEDs 7 Figure 7-3. TN574 DS1C Circuit Pack LEDs TN1654 Circuit Pack LEDs The TN1654 DS1CONV board has 11 LEDs on its faceplate. The top 3 system standard LEDs indicate the state of the DS1CONV board. These LEDs are under firmware control until the board has established a link to the SPE via the EI or SNI. Once the link...
Page 270
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 LED Indicators Page 7-12 DS1 CONV (TN574/TN1654) Circuit Pack LEDs 7 2. If the Fiber Channel is down (DS1 Converter circuit pack/fiber endpoint communications), the yellow LED will flash at a 1 Hz rate (on for 500 ms, off for 500 ms). 3. If the DS1 Control Channel is down between the two DS1CONVs in the DS1CONV Complex, the yellow LED will pulse at a 0.5 Hz rate (on for 1 second,...