Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 331

Value Query Capability Group
Issue 6  June 1997
5-147
Party ID Information on Call Query
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x? assigned value
Second CRV Byte0x? assigned value
Message Type 0x64 REGister
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag = invoke 0xa1 INVOKE component
component length 0x?? computed length
component length0x??...

Page 332

Byte Level Messages
5-148Issue 6  June 1997 
Extension Type/Class Information Query
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x? assigned value
Second CRV Byte0x? assigned value
Message Type 0x64 REGister
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag = invoke 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long...

Page 333

Value Query Capability Group
Issue 6  June 1997
5-149
Integrated Directory Database Query
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Octet 0x? assigned value
Second CRV Octet0x? assigned value
Message Type 0x64 REGister
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag = invoke 0xa1 INVOKE component
component length 0x?? computed length
component...

Page 334

Byte Level Messages
5-150Issue 6  June 1997 
Value Query: REGister Messages Sent by the
switch
None for this capability group.
Value Query: FACility Messages Sent by the
switch
A FACility message is used to initiate an action within an existing association on 
an active CRV. All FACility messages have the Protocol Discriminator and the 
CRV followed by a FAC type = 0x62. 

Page 335

Value Query Capability Group
Issue 6  June 1997
5-151
Response to Agent Login Query (List of
Logged-in Agent Extensions)
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long...

Page 336

Byte Level Messages
5-152Issue 6  June 1997 
Value Query: RELease COMplete Messages Sent
by the Adjunct
A RELease COMplete message terminates an association on an existing CRV. All 
RELease COMplete messages have the Protocol Discriminator and the CRV 
followed by a REL COM type = 0x5a. 
See “RELease COMplete Messages Sent by the switch and the Adjunct.”
Value Query: RELease COMplete Messages Sent
by the switch
A RELease COMplete message terminates an association on an existing CRV. All 
RELease COMplete...

Page 337

Value Query Capability Group
Issue 6  June 1997
5-153
Response to ACD Split Status Query
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x5a RELease COMplete
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa2 RETURN RESULT 
component
component length 0x?? computed length
component...

Page 338

Byte Level Messages
5-154Issue 6  June 1997 
The value will take up two bytes if the value is greater than 127. The high order 
bits will be first followed by 0x80 | low order bits.Response to ACD Split Status Query —(continued)
Byte Description Byte Value Comments
The Counter IE  0x46
Length of IE  0x02 or 0x03
Type = Number of Available Agents 0x85
* Ext bit | Value < 127 (NOTE 1) 0x?? 0x80 | # avail. agents 

Page 339

Value Query Capability Group
Issue 6  June 1997
5-155
Response to Agent Status Query
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x5a RELease COMplete
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa2 RETURN RESULT 
component
component length 0x?? computed length
component length0x??...

Page 340

Byte Level Messages
5-156Issue 6  June 1997 
NOTE:
This IE will only be present if the System-Parameters Feature field, AUX Reason Code, 
is “forced” or “requested,” and the agent’s work mode is AUX.Response to Agent Status Query —(continued)
Byte Description Byte Value Comments
The Domain IE  0x49Note
Length of Domain IE  0x? Computed length
Domain type = Reason code 0x98 Reason code
Reason code 0x8X 0x81- 0x89
(Reason codes 1-9) 