Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 341
Value Query Capability Group Issue 6 June 1997 5-157 Response to Station Message Waiting Lamp Status Query NOTE: Bits 1 through 5 in byte 4 of the Status IE give the MWL on/off status of each switch messaging service. The adjunct should logically OR these bits. If the result is “1,” the lamp is on; otherwise, it is off. The adjunct must logically OR bits 1 through 5. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x?...
Page 342
Byte Level Messages 5-158Issue 6 June 1997 Response to Station Send-All-Calls Status Query Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa2 RETURN RESULT component component length 0x?? computed length component length0x?? long form...
Page 343
Value Query Capability Group Issue 6 June 1997 5-159 Response to Station Call Forwarding Status Query Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa2 RETURN RESULT component component length 0x?? computed length component length0x?? long...
Page 344
Byte Level Messages 5-160Issue 6 June 1997 Response to Station Status Query Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa2 RETURN RESULT component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 345
Value Query Capability Group Issue 6 June 1997 5-161 Response to Trunk Status Query NOTE: Trunks idle (available) + Trunks in use = trunks in service. The switch does not return counts for maintenance busy and otherwise unavailable. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932...
Page 346
Byte Level Messages 5-162Issue 6 June 1997 Response to Number of Call Classifiers Query 1. If the USA default algorithm field is set to n on the System Parameters OCM Call Classfication form, then the query will provide the total number of ports for TN744D and TN2182 boards (and later versions) that are idle and in-use. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to...
Page 347
Value Query Capability Group Issue 6 June 1997 5-163 Response to Call Query Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa2 RETURN RESULT component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 348
Byte Level Messages 5-164Issue 6 June 1997 NOTES: All bytes of this message from the sequence tag forward are present if, and only if, there are calls at the station for which the query was made. The presence of such calls results in parameters (call identity, party identity, and state) in this return result component. A return result component only contains a sequence tag and operation value when parameters are present. There is an association of the Nth call ID, party ID, and specific event....
Page 349
Value Query Capability Group Issue 6 June 1997 5-165 Response to Party ID Query Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa2 RETURN RESULT component component length 0x?? computed length component length0x?? long form (length > 127)...
Page 350
Byte Level Messages 5-166Issue 6 June 1997 NOTE: There is a correspondence between the Nth party ID IE and the Nth Connected Number IE.Response to Party ID Query —(continued) Byte Description Byte Value Comments Ext bit | Party ID0x?? Ext bit | Party ID (second byte)0x??