Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server And GuestWorks Property Management System Interface Specifications. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 71

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
59 Message Waiting 
Message Waiting
The Message Waiting feature turns on and turns off message waiting lamps in a 
room under two conditions:
nWhen the switch receives a message from the PMS
nWhen a user presses the Message Waiting Notification button on the atten-
dant console or a telephone (with notification to the PMS).
This feature controls...

Page 72

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
60 Message Waiting 
Operational Considerations
The Message Waiting feature message(s) will be sent and/or received and inter-
preted based on whether the Message Waiting Configuration option on the switch 
is enabled for PMS support. The possibilities are as follows:
nFeature active in switch with communication enabled on switch changes 
and...

Page 73

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
61 Message Waiting 
Feature Active Without PMS
With the Message Waiting Configuration option disabled (act-nopms), the switch 
does not send message waiting messages to the PMS. If the PMS sends mes-
sage waiting messages to the switch, the switch will ACK the message. However, 
the switch will send a violation message to the PMS and not act on...

Page 74

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
62 Controlled Restriction 
Controlled Restriction
The Controlled Restriction feature enables an RSN to be restricted using selected 
origination and/or termination capabilities either from switch terminals (with com-
munication to the PMS), or on receipt of feature messages from the PMS.
NOTE:
The switch also has the capability to apply...

Page 75

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
63 Controlled Restriction 
Operational Considerations
The controlled restriction message communication with the PMS is based on the 
switch installation parameters. The possibilities are as follows:
nThe feature is active in the switch with no communication with the PMS 
(act-nopms).
nThe feature is active in the switch and communication with...

Page 76

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
64 Controlled Restriction 
When a controlled restriction is set on an RSN, the denied outward/toll, 
termination, station-to-station/toll, and origination calls are routed to the translated 
intercept treatment.
The switch automatically removes previous single user-controlled restrictions, 
imposes controlled outward restriction on room...

Page 77

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
65 Check-In/Check-Out 
Check-In/Check-Out
The Check-in/Check-out messages do not represent a unique feature, but rather 
are a convenient device for invoking a sequence of functions commonly per-
formed when a guest checks in or checks out of a room. It is expected that each 
check-in or check-out performed in the PMS will immediately be...

Page 78

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
66 Check-In/Check-Out 
Process Codes
The process codes for the Check-In/Check-Out features are shown in Table 14.
The process codes for the Check-In feature are shown in Table 15
 and Table 16. Table 14. Check-In/Check-Out Process Codes [Feature Code 16 (N)]
Process 
CodeMessage 
Direction Indications
1 PMS to Switch Switch is to perform the...

Page 79

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
67 Check-In/Check-Out 
The process codes for the Check-Out feature are shown in Ta b l e 1 7
Operational Considerations
The switch will maintain a vacant/occupied status for each RSN. The two possible 
states for a room are vacant or occupied. These two switch states will be updated 
by the receipt of the check-in and check-out messages from the...

Page 80

DEFINITY ECS and GuestWorks Property Management System
Interface Specifications  555-231-601  Issue 2
December 1999
Feature Codes, Process Codes, and Operations 
68 Check-In/Check-Out 
If the PMS link is down, check-in and check-out must be done at both the PMS 
terminal and at the attendant console or telephones. This procedure must 
continue until the PMS link is up again. For the DEFINITY G3V2 through G3V4, 
DEFINITY ECS, and GuestWorks, you can use the   button at the 
attendant console to determine...