Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server And GuestWorks Property Management System Interface Specifications. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 71
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 59 Message Waiting Message Waiting The Message Waiting feature turns on and turns off message waiting lamps in a room under two conditions: nWhen the switch receives a message from the PMS nWhen a user presses the Message Waiting Notification button on the atten- dant console or a telephone (with notification to the PMS). This feature controls...
Page 72
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 60 Message Waiting Operational Considerations The Message Waiting feature message(s) will be sent and/or received and inter- preted based on whether the Message Waiting Configuration option on the switch is enabled for PMS support. The possibilities are as follows: nFeature active in switch with communication enabled on switch changes and...
Page 73
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 61 Message Waiting Feature Active Without PMS With the Message Waiting Configuration option disabled (act-nopms), the switch does not send message waiting messages to the PMS. If the PMS sends mes- sage waiting messages to the switch, the switch will ACK the message. However, the switch will send a violation message to the PMS and not act on...
Page 74
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 62 Controlled Restriction Controlled Restriction The Controlled Restriction feature enables an RSN to be restricted using selected origination and/or termination capabilities either from switch terminals (with com- munication to the PMS), or on receipt of feature messages from the PMS. NOTE: The switch also has the capability to apply...
Page 75
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 63 Controlled Restriction Operational Considerations The controlled restriction message communication with the PMS is based on the switch installation parameters. The possibilities are as follows: nThe feature is active in the switch with no communication with the PMS (act-nopms). nThe feature is active in the switch and communication with...
Page 76
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 64 Controlled Restriction When a controlled restriction is set on an RSN, the denied outward/toll, termination, station-to-station/toll, and origination calls are routed to the translated intercept treatment. The switch automatically removes previous single user-controlled restrictions, imposes controlled outward restriction on room...
Page 77
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 65 Check-In/Check-Out Check-In/Check-Out The Check-in/Check-out messages do not represent a unique feature, but rather are a convenient device for invoking a sequence of functions commonly per- formed when a guest checks in or checks out of a room. It is expected that each check-in or check-out performed in the PMS will immediately be...
Page 78
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 66 Check-In/Check-Out Process Codes The process codes for the Check-In/Check-Out features are shown in Table 14. The process codes for the Check-In feature are shown in Table 15 and Table 16. Table 14. Check-In/Check-Out Process Codes [Feature Code 16 (N)] Process CodeMessage Direction Indications 1 PMS to Switch Switch is to perform the...
Page 79
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 67 Check-In/Check-Out The process codes for the Check-Out feature are shown in Ta b l e 1 7 Operational Considerations The switch will maintain a vacant/occupied status for each RSN. The two possible states for a room are vacant or occupied. These two switch states will be updated by the receipt of the check-in and check-out messages from the...
Page 80
DEFINITY ECS and GuestWorks Property Management System Interface Specifications 555-231-601 Issue 2 December 1999 Feature Codes, Process Codes, and Operations 68 Check-In/Check-Out If the PMS link is down, check-in and check-out must be done at both the PMS terminal and at the attendant console or telephones. This procedure must continue until the PMS link is up again. For the DEFINITY G3V2 through G3V4, DEFINITY ECS, and GuestWorks, you can use the button at the attendant console to determine...