DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 747 ISDN trunk group 17 Carrier Medium This field lets you to specify the type of transport medium interface used for the ISDN trunk group. Appears only when the Group Type field is isdn and, on the System-Parameters Customer-Options screen, either the Async. Transfer Mode (ATM) Trunking or H.323 field is y. Charge Advice Use this field to accumulate and access charge information about a call. You...
Page 772
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 748 ISDN trunk group 17 Codeset to Send Display This field defines the codeset for sending the information element for Display. The value depends on the type of switch to which the user is connected. Codeset to Send National IEs This field defines the codeset for sending the information element (IE) for national IEs. National IEs include all IEs previously sent only in code set 6 (such as DCS IE). Now...
Page 773
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 749 ISDN trunk group 17 Digit Handling (in/out) This field defines whether overlap receiving and overlap sending features are enabled. Set the field to overlap when you want overlap receiving or overlap sending. Set to enbloc when you do not want these features enabled. The first field value indicates digit receiving and the second value indicates digit sending. There are 4 possible combinations:...
Page 774
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 750 ISDN trunk group 17 The following table indicates the expected ISDN-PRI message size from several Lucent Technologies products. QSIG Value-Added Lucent Provides QSIG-VALU services. This field appears only if the Value-Added Lucent (VALU) field on the System-Parameters Customer-Options screen is y. This field can be set to y only if the Supplementary Service Protocol field on the System-Parameters...
Page 775
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 751 ISDN trunk group 17 Valid entries Usage access A tie trunk giving access to an Electronic Tandem Network. accunetACCUNET Switched Digital Service — part of ACI (AT&T Communications ISDN) phase 2. cbcCall-by-Call service — provides different dial plans for different services on an ISDN trunk group. Indicates this trunk group is used by the Call-By-Call Service Selection feature. dmi-mosDigital...
Page 776
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 752 ISDN trunk group 17 Supplementary Service Protocol Indicates which supplementary service protocol to use for services over this trunk group. Supplementary Service protocols are mutually exclusive. sdnSoftware Defined Network (SDN) — an AT&T communications offering that provides a virtual private network using the public switched network. SDN can carry voice and data between customer locations as...
Page 777
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 753 ISDN trunk group 17 Test Call BCC Indicates the Bearer Capability Code (BCC) used for the ISDN test call. Testcall ITC Controls the encoding of the Information Transfer Capability (ITC) codepoint of the bearer capability IE in the SETUP message when generating an ISDN test call. Allowed values are rest (restricted) and unre (unrestricted). NOTE: ISDN Testcall feature has no routing, so a testcall is...
Page 778
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 754 ISDN trunk group 17 NOTE: The cyclical option cannot be set if the trunk group using ISDN-PRI interfaces is to be used for Wideband operations (the Wideband Support field set to y). The search can be administered per ISDN-PRI trunk group, but it infers the direction of search within all ISDN-PRI facilities (or portions of those facilities) administered within the trunk group. Usage Alloc Appears...
Page 779
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 755 ISDN trunk group 17 Screen 115. ISDN Trunk Group screen These fields are unique to the ISDN trunk group screen. BSR Reply-best DISC Cause Value Switches that are polled as resources in a Best Service Routing application return data to the polling switch in the ISDN DISC message. Since some cause values do not work over some networks, this field sets the cause value that your switch will return in...
Page 780
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 756 ISDN trunk group 17 DCS Signaling Specifies the means used to send the DCS message. This field only appears if the Used for DCS field entry is y and the Service Type field is anything except dmi-mos or sddn. Valid entries are bx.25 for the traditional DCS feature or d-chan for the DCS over ISDN-PRI D-channel feature. DCS over D-channel is not supported on trunk groups containing ISDN-BRI...