Page 61
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-17 Channel Structure and Signaling 4 Notes: 1. CO is any of the following trunk types: CO, FX, and WATS. 2. Tie is any of the following trunk typ es: ac c ess, tie, tand em, RLT, ap lt. 3. If CAS is used on a CO trunk typ e, the c ountry p rotoc ol must b e c orrec t for that c ountry. 4. The TN767 c annot b e used for ISDN PRI sig naling on a G3rV2. It...
Page 62
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-18 Line Coding 4 Line Coding Line c oding is the pattern that d ata assumes as it is prop ag ated over a c ommunic ations c hannel. Dig ital trunks on DEFINITY systems use the following line cod ing s: nAlternate Mark Inversion (G3 V2 only, CEPT1 interfac es only) nAlternate Mark Inversion with Zero Cod e Sup p ression (all systems, DS1 interfac es...
Page 63
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-19 Line Coding 4 Figure 4-3. Alternating Mark Inversion Alternating Mark Inversion Line Coding All transmissions g enerated b y d ig ital trunk ports are enc od ed in AMI. AMI was d esig ned to fill the line rep eater’s need for d ep end ab le and rec urring voltag e c hanges on the line. With AMI, every 1 in the transmission stream c hang es the line...
Page 64
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-20 Line Coding 4 c od ing sub stitutes a p red etermined b it string for every g roup of eig ht c onsec utive zeros that it find s in the transmission stream. The p red etermined sub stitute string c ontains intentional b ip olar p ulse violations so that it c an b e rec ognized at the rec eiving end . Thus, unlike with ZCS, B8ZS line c od ing will...
Page 65
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-21 Line Coding 4 1. 100V if there has b een an even numb er of 1s sinc e the last substitution. V means a b ip olar violation. For examp le, if the last 1 was a + , the V would be a +. 2. 000V if there has b een an od d numb er of 1s sinc e the last sub stitution. To illustrate HDB3, c onsid er the following string : Input bit stream 1011 0000 01...
Page 66
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-22 Line Coding 4 ac hieved . Mod e 3 d ata is restric ted if it is inverted b ec ause it is p ac kag ed in an un-inverted LAPD protocol. NOTE: The terms restric ted d ata and unrestric ted data are c onfusing b ec ause restric ted d ata is d ata that c an b e transp orted over any fac ility and is thus less restric ted (in an intuitive sense) than...
Page 67
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-23 Line Coding 4 Notes: 1. The mod e-2 hand shake will not work over other than 64-kb p s fac ilities (for example, robbed-bit facilities). 2. Other MPDMs are the High Speed Sync hronous MPDM and the Vid eo Teleconferenc ing MPDM. The only difference b etween them is that the Vid eo Teleconferenc ing MPDM has an RS-366 interfac e for keyb oard dialing...
Page 68
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-24 Line Coding 4 4. Mod e-3 d ata c an only b e c irc uit-switched in Generic 2.2 and G3V2 systems. Also, mod e 3 on the 3270 A and 3270 T req uires a 3270 C on the far-end . 5. Mod e 2 on the PC/PBX c onnec tion is supp orted und er the ASCII terminal emulation p ac kag e. The PC/PBX c onnec tion in mode 2 uses a mod e-3/2 ad ap tive hand shake if the b...
Page 69
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-25 Line Compensation 4 NOTE: It is rec ommend ed that the D c hannel not b e inverted if B8ZS is ad ministered . G2.2 Line Coding Implementation G2.2 imp lements line c od ing in p roc ed ure 260, word1, field 9. This ad ministration is req uired for all DS1-b ased trunk b oard s, inc luding those in the universal mod ule. You c an c hoose either B8ZS...
Page 70
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Physical Layer Page 4-26 Idle Code 4 The value entered into the Line Compensation field of this form should b e set to the leng th of the c ab le from the DS1/CEPT1 c irc uit p ac k to the CSU. If the c ab le is c onnec ted to another DS1/CEPT1 interfac e that also p erforms line c omp ensation, the value should b e set to one half the leng th of the c ab le. Idle Code...