Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Communications System Generic 2.2 And Generic 3 V2 DS1/CEPT1/ISDN PRI Reference Manual

Lucent Technologies DEFINITY Communications System Generic 2.2 And Generic 3 V2 DS1/CEPT1/ISDN PRI Reference Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Communications System Generic 2.2 And Generic 3 V2 DS1/CEPT1/ISDN PRI Reference Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 31

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-2  
3
Table 3-1. Equipment and Software Requirements
Item Systems Remarks
TN464C G3V2 Universal DS1/CEPT1 b oard . It is 
required for all CEPT1-based trunks. It is 
also req uired  for ISDN PRI D c hannels on 
G3r. It is also req uired  for wid eband  
switc hing. The TN464D or later is 
req uired for ap p lic ations in Belg ium, the...

Page 32

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-3  
3
TN780 All G3V2 systems Tone/c loc k. Req uired  for Stratum 3 c loc k.
TN463 G2.2 trad itional 
and  universal 
mod ulesSystem c loc k sync hronizer. One TN463 is 
req uired per system. It is loc ated  in the 
TMS c arrier for multi-mod ule systems or 
in the mod ule c ontrol c arrier for sing le 
mod ule systems.
TN771B/C G3V2, G2.2...

Page 33

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-4 ANN11C and ANN35 Line Compensation Jumper Settings 
3
ANN11C and ANN35 Line
Compensation Jumper Settings
Unlike the TN722, TN767, and  TN464C board s, the ANN11 and  ANN35 have a 
switc h that must b e set for the leng th of the c ab le from the b oard  to the CSU. 
Following  are the setting s:Sync hronization
cableG2.2 universal 
and...

Page 34

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-5 TN464C Jumper Settings 
3
TN464C Jumper Settings
If the TN464C or later is used , two jump ers on the b oard  must b e installed  
c orrec tly. These jump ers are on the lower left quad rant of the b oard  as you look 
at the b oard  with the front p anel in your rig ht hand . One jump er c ontrols the b it 
rate and  the other c ontrols...

Page 35

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-6 TN464C Jumper Settings 
3
Figure 3-1. Bit Rate and Impedance Jumpers on the TN464C
To p
BottomFaceplat
e
Backplane
connectors
24/32 channel selector
75/120 ohm selector
24 CHNL
120 OHM 32 CHNL
75 OHMInser t the jumpers into
theblockssoastojoin
the center row of pins
and the row designating
the desired options.
ckdf464 LJK 060597
TN464C/D 

Page 36

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-7 DS1/CEPT1 Board Cable to CSU 
3
DS1/CEPT1 Board Cable to CSU
A stand ard  c ab le is p rovid ed  with the DS1/CEPT1 b oard  for c onnec ting  to a CSU 
or other network terminating  eq uip ment, suc h as a T1 multip lexer or a T1 
mic rowave. This c ab le is 50 feet in leng th and c omes eq uip ped  with a 25-p in 
c onnec tor at the G3V2...

Page 37

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-8 ESF T1 Channel Service Unit 
3
ESF T1 CSU Switch Settings
The ESF T1 CSU should  b e optioned  to ag ree with the switc h administration. 
Thus, if the system is op tioned  for ESF framing  format, for examp le, so should  the 
CSU. The ESF T1 CSU should  also b e set to pass ESF and  CRC-6 information 
transparently throug h the CSU to...

Page 38

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-9 ESF T1 Channel Service Unit 
3
SW3 SW3 This switc h is unused . All eig ht switc hes are fac tory set 
to op en.
SW4 SW2 This switc h is unused . All eig ht switc hes are fac tory set 
to op en.
SW5-1 SW1-8 op en This setting  ind ic ates that the switc h is ESF framed . ESF 
framing  must also b e set in the DS1 c irc uit p ac k 
ad...

Page 39

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-10 ESF T1 Channel Service Unit 
3
SW5-5 SW1-4 c losed This setting  allows CRC-6 c ode g enerated  b y the switc h 
to b e p assed  throug h the CSU unaltered  to the T1 
fac ility. Ag ain, this is the c orrec t setting  if the switc h is 
op tioned  for ESF framing . The op en p osition terminates 
the CRC-6 from the switc h.
SW5-6 SW1-3...

Page 40

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
Equipment and Software Requirements 
Page 3-11 ESF T1 Channel Service Unit 
3
Switc hes SW7 on the stand-alone unit and  SW8 on the multiline unit should  b e set 
for the leng th of the c ab le from the switc h to the CSU. The setting s for the two 
CSUs are d ifferent, however. Following  are the setting s for the standalone unit:
sw 7-1  7-2  7-3   (7-4 to 7-9 not used)
     0 -...