Page 31
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-2 3 Table 3-1. Equipment and Software Requirements Item Systems Remarks TN464C G3V2 Universal DS1/CEPT1 b oard . It is required for all CEPT1-based trunks. It is also req uired for ISDN PRI D c hannels on G3r. It is also req uired for wid eband switc hing. The TN464D or later is req uired for ap p lic ations in Belg ium, the...
Page 32
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-3 3 TN780 All G3V2 systems Tone/c loc k. Req uired for Stratum 3 c loc k. TN463 G2.2 trad itional and universal mod ulesSystem c loc k sync hronizer. One TN463 is req uired per system. It is loc ated in the TMS c arrier for multi-mod ule systems or in the mod ule c ontrol c arrier for sing le mod ule systems. TN771B/C G3V2, G2.2...
Page 33
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-4 ANN11C and ANN35 Line Compensation Jumper Settings 3 ANN11C and ANN35 Line Compensation Jumper Settings Unlike the TN722, TN767, and TN464C board s, the ANN11 and ANN35 have a switc h that must b e set for the leng th of the c ab le from the b oard to the CSU. Following are the setting s:Sync hronization cableG2.2 universal and...
Page 34
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-5 TN464C Jumper Settings 3 TN464C Jumper Settings If the TN464C or later is used , two jump ers on the b oard must b e installed c orrec tly. These jump ers are on the lower left quad rant of the b oard as you look at the b oard with the front p anel in your rig ht hand . One jump er c ontrols the b it rate and the other c ontrols...
Page 35
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-6 TN464C Jumper Settings 3 Figure 3-1. Bit Rate and Impedance Jumpers on the TN464C To p BottomFaceplat e Backplane connectors 24/32 channel selector 75/120 ohm selector 24 CHNL 120 OHM 32 CHNL 75 OHMInser t the jumpers into theblockssoastojoin the center row of pins and the row designating the desired options. ckdf464 LJK 060597 TN464C/D
Page 36
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-7 DS1/CEPT1 Board Cable to CSU 3 DS1/CEPT1 Board Cable to CSU A stand ard c ab le is p rovid ed with the DS1/CEPT1 b oard for c onnec ting to a CSU or other network terminating eq uip ment, suc h as a T1 multip lexer or a T1 mic rowave. This c ab le is 50 feet in leng th and c omes eq uip ped with a 25-p in c onnec tor at the G3V2...
Page 37
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-8 ESF T1 Channel Service Unit 3 ESF T1 CSU Switch Settings The ESF T1 CSU should b e optioned to ag ree with the switc h administration. Thus, if the system is op tioned for ESF framing format, for examp le, so should the CSU. The ESF T1 CSU should also b e set to pass ESF and CRC-6 information transparently throug h the CSU to...
Page 38
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-9 ESF T1 Channel Service Unit 3 SW3 SW3 This switc h is unused . All eig ht switc hes are fac tory set to op en. SW4 SW2 This switc h is unused . All eig ht switc hes are fac tory set to op en. SW5-1 SW1-8 op en This setting ind ic ates that the switc h is ESF framed . ESF framing must also b e set in the DS1 c irc uit p ac k ad...
Page 39
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-10 ESF T1 Channel Service Unit 3 SW5-5 SW1-4 c losed This setting allows CRC-6 c ode g enerated b y the switc h to b e p assed throug h the CSU unaltered to the T1 fac ility. Ag ain, this is the c orrec t setting if the switc h is op tioned for ESF framing . The op en p osition terminates the CRC-6 from the switc h. SW5-6 SW1-3...
Page 40
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 Equipment and Software Requirements Page 3-11 ESF T1 Channel Service Unit 3 Switc hes SW7 on the stand-alone unit and SW8 on the multiline unit should b e set for the leng th of the c ab le from the switc h to the CSU. The setting s for the two CSUs are d ifferent, however. Following are the setting s for the standalone unit: sw 7-1 7-2 7-3 (7-4 to 7-9 not used) 0 -...