Page 181

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-7 G3V2 Administration 
6
The c hoic e of isdn-ext
 req uires the c irc uit p ac k be a TN767, 
TN464B or TN464C or later release DS1/CEPT1 interfac e. This 
c hoic e will enab le the board  to use ISDN sig naling  with the D 
c hannel assoc iated  with a d ifferent DS1/CEPT1 interfac e.
The c hoic e of the isdn-pri
 p arameter along  with Bit Rate
 set...

Page 182

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-8 G3V2 Administration 
6
Country 
Protoc olG3V2 only
Va l u e s :
A numb er from 1 to 17. Default is 1
.
Re f e re n c e :
Se c t io n  ‘‘Country-Sp ec ific  Layer 3 in G3V2’’ in Chap ter 5, 
‘‘Layers 2 and 3’’.
This field  will only b e d isp layed  if the Signaling Mode
 is 
isdn-pri
, isdn-ext
, or CAS
. This field  is used  for ISDN c alls and  
for...

Page 183

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-9 G3V2 Administration 
6
Connec tVa l u e s :
host
network (d efault)
pbx
Re f e re n c e :
Se c t io n  ‘‘User-Network and  Peer Protoc ols’’ in Chapter 5, 
‘‘Layers 2 and 3’’.
Th e  Connect
 field  will only ap p ear if isdn-pri
 signaling is 
c hosen. This field  ind ic ates what is on the far end  of the PRI in 
ord er to c ontrol the layers 2 and  3...

Page 184

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-10 G3V2 Administration 
6
InterfaceVa l u e s :
network
p eer-master (G3V2 only)
p eer-slave (G3V2 only)
user (d efault)
Re f e re n c e :
Se c t io n  ‘‘User-Network and  Peer Protoc ols’’ in Chapter 5, 
‘‘Layers 2 and 3’’.
This field  will only ap p ear if pbx
 is c hosen as the Connect
 
value. If you administer user
, the system is user at b oth...

Page 185

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-11 G3V2 Administration 
6
G2.2 G3V2
Administered as Layer 2 Layer 3 Administered as Layer 2 Layer 3
user user user network network network
user user user peer-master/side A (G3V2 only) master side A
network network network p eer-slave/sid e B (G3V2 only) slave sid e B
NOTE:
When c onnec ting two DEFINITY systems via ISDN PRI, 
you should  use the...

Page 186

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-12 G3V2 Administration 
6
CRC G3V2 only
Va l u e s :
no (d efault)
yes
This field  will only ap p ear if CAS
 is c hosen as the sig naling  
mod e. The CRC
 field ind ic ates whether the c yc lic al red und anc y 
c hec k is to b e d one on the b oard .
Idle Code G3V2 only
Va l u e s :
An 8-d ig it b inary numb er in the rang e 00000000 to 11111111....

Page 187

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-13 G3V2 Administration 
6
DMI-BOSVa l u e s :
no
yes (d efault)
Re f e re n c e :
Se c t io n  ‘‘Channel Struc ture and  Sig naling ’’ in Chap ter 4, 
‘‘Physic al Layer’’.
This field only appears when the Bit Rate
 is 1.544
. DMI-BOS 
y
 selec ts a mode of op eration that is c omp atib le with the 
DMI-BOS stand ard . Its use req uires a TN722B or TN767...

Page 188

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-14 G3V2 Administration 
6
Synchronization Plan Form Settings
Refer to the sec tion ‘‘Sync hronization’’ in Chap ter 4, ‘‘Physical Layer’’ for further 
information on sync hronizing  the system.
Using  the c ommand  change synchronization
, enter the stratum, either 3 or 4, 
and  the b oard  loc ations of the p rimary and  sec ond ary timing  sourc es. If...

Page 189

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-15 G3V2 Administration 
6
Sec ond ary D 
c hannelVa l u e s :
Port loc ation of the b ac kup D c hannel. The default is b lank.
This field will only appear if this signaling group is an NFAS 
sig naling  g roup . It ind ic ates the sec ond ary D c hannel in this 
signaling group. NFAS is supported only in country option 1.
Trunk Group  
for Channel...

Page 190

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-16 G3V2 Administration 
6
Signaling Group Form Settings — Pages 2-5
Pages 2-5 of the sig naling group  form are for ad ministering NCA-TSCs. Not all 
NCA-TSCs have to b e ad ministered . The ISDN DCS feature req uires one 
NCA-TSC to b e ad ministered  p er log ic al DCS c hannel, however.
The following  list d esc rib es the ad ministration setting s...