Page 211

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-37 G3V2 Administration 
6
IXCValues:
A valid three d ig it interexc hang e c arrier c od e or b lank.
Re f e re n c e :
Se c t io n  ‘‘Network Sp ec ific  Fac ilities IE in U.S.’’ in Chap ter 5, 
‘‘Layers 2 and 3’’.
This field  ap p lies only to ISDN PRI trunk g roup s. Enter the c od e 
of the long d istanc e c arrier you want to c arry c alls in this...

Page 212

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-38 G3V2 Administration 
6
TSC G3V2-only
Values:
yes
no
Re f e re n c e :
Se c t io n  ‘‘Temp orary Sig naling Connec tions’’ in Chapter 5, 
‘‘Layers 2 and 3’’.
If this trunk g roup  is to b e used  for tand eming  or estab lishing  
TSCs, enter yes
.
CA-TSC 
Req ue stG3V2-only
Values:
as-needed
at-setup
Re f e re n c e :
Se c t io n  ‘‘Temp orary Sig...

Page 213

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-39 G3V2 Administration 
6
ITC G3V2-only
Values:
res
unr
both
Re f e re n c e :
Se c t io n s ‘‘Bearer Capability IE’’ and‘‘Low Layer Comp atib ility 
IE’’ in Chap ter 5, ‘‘Layers 2 and  3’’.
This field  ap pears only if one or more of the field s in BCC is y
. 
The ITC of the orig inating  end p oint, whic h c an b e an ISDN or 
DCP d ata mod ule, is c...

Page 214

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-40 G3V2 Administration 
6
CPN Prefix Table Form Settings
This form allows you to d ec id e whic h extensions will b e used  to send  c alling  
p arty and /or c onnec ted  p arty numb er for ISDN PRI c alls. The following  list 
d esc rib es the ad ministration setting s for the ISDN PRI-sp ec ific  field s in this 
ad ministration form. For more...

Page 215

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-41 G3V2 Administration 
6
Terminating Extension Group Form Settings
The only field  on this sc reen ap p lic ab le to ISDN PRI is the ISDN Caller 
Display
 field. You must enter either grp-name
 or mbr-name
 to sp ec ify whether 
the TEG g roup  name or memb er name is sent to the orig inating  user when a 
memb er of a TEG answers. Ex t  C o d e...

Page 216

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-42 G2.2 Administration 
6
Hunt Group Form Settings
The only field  on this sc reen ap p lic ab le to ISDN PRI is the ISDN Caller 
Display
 field. You must enter either grp-name
 or mbr-name
 to sp ec ify whether 
the hunt g roup  name or member name is sent to the far end  when a memb er of a 
hunt group  answers.
G2.2 Administration
The following  sec...

Page 217

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-43 G2.2 Administration 
6
nProc ed ure 100 Word  1:  Trunk Group  Typ e Sig naling  and Dial Ac c ess (ID) 
Code
nProc ed ure 100 Word 2:  Trunk Group  Data Translations
nProc ed ure 100 Word 3:  ISDN Trunk Group  Sig naling  Op tions
nProc ed ure 101 Word 1:  ISDN Trunk Group , CDR, and  Dig ital Loss Plan
nProc ed ure 101 Word 3:  Prefix Dig its
nProc...

Page 218

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-44 G2.2 Administration 
6
Procedure 276 Word 1: Other Feature Groups
Use this p roc ed ure to turn on op tional networking  features suc h as AAR, DCS, 
SNC, Look-Ahead  Interflow, and  Integ rated  Telemarketing  Gateway (ITG) or to 
see whic h of these features are turned  on.
Procedure 250 Word 1: SC/DS1 —
Carrier Designation
This p roc ed ure is used...

Page 219

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-45 G2.2 Administration 
6
Dep end ing  on whether the p urp ose for translating  this proc ed ure is to assig n the 
SC or to assig n a DS1 p ort c arrier will d etermine whic h enc ode to selec t. 
Fields 5-10
DS1/DMI/ISDN-PRI d oes not p lac e any ad d itional req uirements on translating  
these field s.
Field 11
Field encodes and their descriptions...

Page 220

DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT1/ISDN PRI Reference  
555-025-107  Issue 1
July 1993
System Administration 
Page 6-46 G2.2 Administration 
6
Notes:
1. The c irc uit p ac k app lic ation typ e (Field  14) will to a larg e d eg ree 
d etermine whic h slots may be used .
2. When a DS1/MFAT c arrier is c onfig ured  with two DS1s, p hysic al slots 3, 8, 
16, and  21 are availab le for other ap p lic ations. If only one DS1 is 
c onfig ured , then six ad d itional slots...