Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Communications System Generic 2.2 And Generic 3 V2 DS1/CEPT1/ISDN PRI Reference Manual
Lucent Technologies DEFINITY Communications System Generic 2.2 And Generic 3 V2 DS1/CEPT1/ISDN PRI Reference Manual
Here you can view all the pages of manual Lucent Technologies DEFINITY Communications System Generic 2.2 And Generic 3 V2 DS1/CEPT1/ISDN PRI Reference Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 211
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-37 G3V2 Administration 6 IXCValues: A valid three d ig it interexc hang e c arrier c od e or b lank. Re f e re n c e : Se c t io n ‘‘Network Sp ec ific Fac ilities IE in U.S.’’ in Chap ter 5, ‘‘Layers 2 and 3’’. This field ap p lies only to ISDN PRI trunk g roup s. Enter the c od e of the long d istanc e c arrier you want to c arry c alls in this...
Page 212
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-38 G3V2 Administration 6 TSC G3V2-only Values: yes no Re f e re n c e : Se c t io n ‘‘Temp orary Sig naling Connec tions’’ in Chapter 5, ‘‘Layers 2 and 3’’. If this trunk g roup is to b e used for tand eming or estab lishing TSCs, enter yes . CA-TSC Req ue stG3V2-only Values: as-needed at-setup Re f e re n c e : Se c t io n ‘‘Temp orary Sig...
Page 213
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-39 G3V2 Administration 6 ITC G3V2-only Values: res unr both Re f e re n c e : Se c t io n s ‘‘Bearer Capability IE’’ and‘‘Low Layer Comp atib ility IE’’ in Chap ter 5, ‘‘Layers 2 and 3’’. This field ap pears only if one or more of the field s in BCC is y . The ITC of the orig inating end p oint, whic h c an b e an ISDN or DCP d ata mod ule, is c...
Page 214
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-40 G3V2 Administration 6 CPN Prefix Table Form Settings This form allows you to d ec id e whic h extensions will b e used to send c alling p arty and /or c onnec ted p arty numb er for ISDN PRI c alls. The following list d esc rib es the ad ministration setting s for the ISDN PRI-sp ec ific field s in this ad ministration form. For more...
Page 215
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-41 G3V2 Administration 6 Terminating Extension Group Form Settings The only field on this sc reen ap p lic ab le to ISDN PRI is the ISDN Caller Display field. You must enter either grp-name or mbr-name to sp ec ify whether the TEG g roup name or memb er name is sent to the orig inating user when a memb er of a TEG answers. Ex t C o d e...
Page 216
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-42 G2.2 Administration 6 Hunt Group Form Settings The only field on this sc reen ap p lic ab le to ISDN PRI is the ISDN Caller Display field. You must enter either grp-name or mbr-name to sp ec ify whether the hunt g roup name or member name is sent to the far end when a memb er of a hunt group answers. G2.2 Administration The following sec...
Page 217
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-43 G2.2 Administration 6 nProc ed ure 100 Word 1: Trunk Group Typ e Sig naling and Dial Ac c ess (ID) Code nProc ed ure 100 Word 2: Trunk Group Data Translations nProc ed ure 100 Word 3: ISDN Trunk Group Sig naling Op tions nProc ed ure 101 Word 1: ISDN Trunk Group , CDR, and Dig ital Loss Plan nProc ed ure 101 Word 3: Prefix Dig its nProc...
Page 218
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-44 G2.2 Administration 6 Procedure 276 Word 1: Other Feature Groups Use this p roc ed ure to turn on op tional networking features suc h as AAR, DCS, SNC, Look-Ahead Interflow, and Integ rated Telemarketing Gateway (ITG) or to see whic h of these features are turned on. Procedure 250 Word 1: SC/DS1 — Carrier Designation This p roc ed ure is used...
Page 219
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-45 G2.2 Administration 6 Dep end ing on whether the p urp ose for translating this proc ed ure is to assig n the SC or to assig n a DS1 p ort c arrier will d etermine whic h enc ode to selec t. Fields 5-10 DS1/DMI/ISDN-PRI d oes not p lac e any ad d itional req uirements on translating these field s. Field 11 Field encodes and their descriptions...
Page 220
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-46 G2.2 Administration 6 Notes: 1. The c irc uit p ac k app lic ation typ e (Field 14) will to a larg e d eg ree d etermine whic h slots may be used . 2. When a DS1/MFAT c arrier is c onfig ured with two DS1s, p hysic al slots 3, 8, 16, and 21 are availab le for other ap p lic ations. If only one DS1 is c onfig ured , then six ad d itional slots...