DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-9 disable/enable Alarm-Origination 3 disable/enable Alarm-Origination The Disab le/Enab le Alarm-Orig ination sc reens are used to temporarily d isable (or reenab le) the automatic alarm rep orting feature, take status of any alarms, and test alarms. It is typ ic ally used b y Luc ent Tec hnolog ies p ersonnel to d isab le alarm rep orting while troubleshooting and rep airing the system....
Page 62
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-10 disable/enable Alarm-Origination 3 status Alarm-Origination The Status Alarm-Orig ination sc reen d isp lays the c urrent status of the alarm orig ination feature. status alarm-origination NOTE: This sc reen c an b e ac c essed while the DEFINITY AUDIX System is in the OA&M state. Field Descriptions Field Name Description Valid Entries (display only) alarm-orig ination Current alarm-orig...
Page 63
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-11 disable/enable Alarm-Origination 3 test Alarm-Origination The Test Results Orig ination sc reen initiates a d emand alarm orig ination test and d isp lays the results of the test. test alarm-origination nPress (Enter) after initially entering the sc reen to start the test. nPress (Canc el) after initially entering the sc reen to return the user to the c ommand line without starting...
Page 64
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-12 disable/enable Alarm-Origination 3 Field Descriptions Field Name Description Valid Entries (display only) Date Date and time test was req uested . Resourc e Typ e of resource b eing tested . Loc . Loc ation of the alarm orig ination resourc e.7 c harac ter string that ind icates port network, carrier, slot, and p ort. For examp le, 01a0201 ind icates p ort-network= 01, carrier= a, slot=...
Page 65
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-13 disable/enable Alarm-Origination 3 Additional Specifications While the test is running , you have three op tions: 1. Press (Canc el) to ab ort the test and return to the c ommand line. 2. Wait for the test to c omp lete. 3. Press (Enter) to p ut the test in the b ac kg round and return to the c ommand line. Ty p e status test to rec onnec t to the sc reen of a test running in b...
Page 66
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-14 display Alarms 3 display Alarms Th e Alarm Rep ort sc reen d isp lays ac tive or resolved DEFINITY AUDIX System alarms. display alarms The Alarm Rep ort sc reen has two p ag es as shown b elow. Use the first pag e to sp ec ify whic h alarms will b e d isp layed in the rep ort.
Page 67
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-15 display Alarms 3 The sec ond p ag e d isp lays the req uested alarm information. Field Descriptions Field Name Description Valid Entries NOTE: The first time this sc reen is used after a restart or reb oot, the field s on the selec tion pag e of the sc reen are b lank. Sub seq uently, eac h field on the selec tion pag e of the sc reen is p op ulated with the value entered the last time the...
Page 68
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-16 display Alarms 3 Resolved ? Disp lays resolved alarms in the alarm rep ort. y (d isplay resolved alarms) n (not d isp lay resolved alarms) NOTE: You may req uest major alarm, minor alarm, warning , or any comb ination of these for a report. Major? Disp lays major alarms in the alarm rep ort. y (d isplay major alarms) n (not d isp lay major alarms) Minor? Disp lays minor alarms in the...
Page 69
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-17 display Alarms 3 Fault Code Fault c ode for the g iven resource type. If this field c ontains a fault c od e, d isp lays only alarms with this fault c od e.0 - 9999 NOTE: Eac h resource typ e has its own set of fault c od es. Therefore, sp ec ifying a fault cod e without a resourc e type name c an d isplay multiple resourc e typ es with the same fault c ode. DISPLAY PAGE Resourc e Typ e...
Page 70
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-18 add Announcement-Set 3 add Announcement-Set The Announc ement Set sc reens are used to add , remove, c op y or list an announc ement set. add announcement set annc-set-name remove announcement set annc-set-name copy announcement set annc-set-name list announcement set annc-set-name Th e announcement-set-name is the name of the announc ement set to b e ac ted up on. Field Descriptions...