DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-59 display Errors 3 Reporting Resource Data Typ e Resourc e type that rep orted the error. Inst Particular instance of the reporting resourc e typ e. Source Line numb er of the sourc e c ode rep orting the error. Date Rec orded Date that the error was rep orted . Time Rec orded Time that the error was rep orted . Cnt Counting the numb er of consecutive id entic al error events — two occ...
Page 112
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-60 display Events 3 display Events The Event Report sc reen d isp lays rep orted DEFINITY AUDIX System maintenanc e events. display events NOTE: The activation c ommands for this screen can b e exec uted by users with craft or higher level login permissions. The d isp lay Events sc reen has two p ag es as shown in the samp le b elow. Use the first p ag e to sp ec ify the typ es of events to...
Page 113
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-61 display Events 3 The sec ond p ag e d isp lays the selec ted event messag es. Field Descriptions Field Name Description Valid Entries SELECTION PAGE The first time this sc reen is used after a restart or reb oot, the field s on the selection p ag e of the sc reen are b lank. Sub seq uently, each field on the selec tion pag e of the sc reen is p op ulated with the value entered the last time...
Page 114
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-62 display Events 3 Time Beg inning hour and minute of the g iven d ay for the alarm rep ort.b lank d ate in hh:mm format The Start Date field must have valid entries before this field can b e used . Session Numb er Session number for nonalarm event typ es in the event rep ort. Only events rep orted d uring this voic e session are d isp layed .b lank 0 to 999 Reporting Resource Ty p...
Page 115
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-63 display Events 3 DISPLAY PAGE For eac h event the following information app ears in an 80 c haracter line. Resourc e Typ e Resourc e type for whic h the event is rep orted . Loc . Loc ation for the resourc e typ e. Event Typ e Typ e of error or alarm event. IN_LINE (error that may req uire some ac tion.) MP_FAIL (error involving the failure of a maintenance p roc ed ure (MP) for the g iven...
Page 116
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-64 display Events 3 NOTE: Some errors d isp lay a sec ond line c ontaining auxiliary information, inc lud ing two 10 d ig it Auxiliary Data p arameters and up to 50 c harac ters of ad d itional information ab out the error. Reporting Resource Data Typ e For error events, resourc e typ e that rep orted the error. For alarm events, alarm severity. Inst For error events, the p artic ular...
Page 117
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-65 change Extensions 3 change Extensions The Chang e Extensions sc reen allows the ad ministrator to c hang e a c ustomer’s switc h d ialing p lan without c hang ing every sub sc rib er’s extension. The ad ministrator also uses the Chang e Extensions sc reen to c hang e a b loc k of sub sc rib er extensions from one rang e of extensions to another rang e. The ad ministrator must sp ec ify the...
Page 118
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-66 change Extensions 3 Field Descriptions If the ad ministrator is moving a b loc k of remote sub sc rib ers extensions from one rang e of extensions to another, the Field Desc riptions table would b e c omp leted in a similar way. The Mac hine Name field would then inc lude the name of the loc al mac hine on whic h the entire b loc k of sub sc rib ers exist. Additional Specifications...
Page 119
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-67 list Extensions 3 list Extensions The List Extension sc reen d isp lays the extensions of loc al sub sc rib ers, starting with lowest extension numb er or the extension sp ec ified in the c ommand line. list extensions list extensions extension Here, extension is the extension numb er that b eg ins the list. Field Descriptions Field Name Description (display only) Extension Extension...
Page 120
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-68 display Fragment 3 display Fragment Th e Fr a g m e n t sc reen is used to c opy, d isp lay or remove a frag ment. copy fragment fragment-id display fragment fragment-id display fragment fragment-id annc-set-name remove fragment fragment-id remove fragment fragment-id annc-set-name Th e fragment-id must sp ec ify an existing frag ment. If the op tional annc-set-name is entered...