Page 281
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-229 change/display System-Parameters Outcalling 3
Page 282
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-230 change/display System-Parameters Outcalling 3 Field Descriptions Name Description Valid Entries Default Outc alling Active? Enab les outc alling on a system wid e basisy (enab led ) n (d isab led )n You may sp ecify up to three time p eriod s. Time p eriods cannot overlap and the sum of their d urations must < 24 hours. Start Time Beg inning outc alling period hh:mm format. 00:00 End...
Page 283
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-231 change System-Parameters Password 3 change System-Parameters Password The System Password sc reen is used to c hang e the system p assword . change system-parameters password Field Descriptions Name Description Valid Entries Customer Log in Pas sw o rdProvid es security b y req uiring the user to enter the p assword for the c urrent customer log in ID before the system p assword c an b...
Page 284
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-232 display/change System-Parameters- Sending Restrictions 3 display/change System-Parameters- Sending Restrictions The Send ing Restrictions sc reen ac tivates the send ing restric tions feature or sp ec ifies a matrix of send ing restric tion c ommunities. display system-parameters sending-restrictions change system-parameters sending-restrictions Field Descriptions Name Description Valid...
Page 285
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-233 display System-Parameters Thresholds 3 display System-Parameters Thresholds The System-Parameters Threshold s sc reen is used to ad minister the sub sc riber and system messag e-sp ac e threshold s. display system-parameters thresholds change system-parameters thresholds Field Descriptions Name Description Valid Entries Default SUBSCRIBER MESSAGE SPACE WARNING The threshold value is interp...
Page 286
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-234 display System-Parameters Thresholds 3 SYSTEM STORAGE SPACE NOTE: The threshold value is interp reted as a percent of total system message sp ace. When this threshold is reac hed , a warning messag e ( lower, mid d le, or upper) ap p ears on the DEFINITY AUDIX status line. Lower Lower messag e sp ac e threshold for the system (the sp ac e available in the voic e text filesystem)0 to 100...
Page 287
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-235 display Time 3 display Time Th e D a t e a n d Ti m e sc reen is used to set or d isp lay the c urrent DEFINITY AUDIX d ate and time or to req uest a manual time sync hronization with the switc h. set time display time NOTE: This sc reen c an b e ac tivated while the DEFINITY AUDIX System is in the OA&M state. Field Descriptions Name Description Valid Entries Date Date that the...
Page 288
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-236 display Time 3 Day of the Month Sets the d ay of the month for the c urrent d ate. An entry is mandatory if the Synchronize to Switc h entry is n.1 to 31 Year Sets the year for the c urrent d ate. An entry is mand atory if the Synchronize to Switc h entry is n.4 digit integers b etween 1990 and 2030 Hour Sets the hour for the c urrent d ate. An entry is mand atory if the Synchronize to...
Page 289
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-237 display Time 3 Sample Tasks To sync hronize the DEFINITY AUDIX time with the switc h time: 1. Type set time and p ress (Enter). 2. Type y in the Sync hronize to Switc h? field, and p ress (Enter) to invoke the op eration. To set the c urrent Year, Month, Day, Hour, or Minute: 1. Type set time and p ress (Enter). 2. Move the c ursor to the d ate/time field (Year, Month, Day,...
Page 290
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-238 change/display Transfer-Dialplan 3 change/display Transfer-Dialplan The Transfer-Dialp lan sc reen is used to d efine the d ialp lan information used for a valid transfer out of DEFINITY AUDIX. This sc reen allows the ad ministrator to d esc rib e the extensions to whic h transfers are p ermitted , and the sub set of extensions to whic h transfers are not p ermitted . change...