DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-139 test MO-Disk 3 Field Descriptions Sample Tasks To initiate a d emand tap e test: 1. Type test mo-disk and p ress (Enter). 2. Press (Canc el) to return to the c ommand line without exec uting the test. While the test is running , you have three op tions: 1. Press (Canc el) to ab ort the test and return to the c ommand line. 2. Wait for the test to c omp lete. 3. Press...
Page 192
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-140 test MO-Disk 3 status Test The status Test sc reen rec onnec ts with a running test, or with the results of the most rec ently run test. status test This c ommand rec onnec ts with the sc reen of the test running in the b ac kg round , or if none, the most rec ently run test. If none, the c ommand c auses an error to be d isp layed (this should oc c ur only when the status test c...
Page 193
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-141 audit Names 3 3audit Names The Aud it Results sc reen initiates a d emand aud it on sub sc rib er names and d isp lays the results of the aud it. audit names Field Descriptions Sample Tasks/Additional Specifications Sa m e a s audit Mailboxes . Name Description (display only) Date Date that the audit was requested . Time Time that the aud it was req uested . Aud it Name Name of the aud it...
Page 194
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-142 audit Network Data 3 audit Network Data The Aud it Results sc reen initiates a d emand aud it on network d ata and displays the results of the aud it. audit network-data Field Descriptions Name Description (display only) Date Date that the audit was requested . Time Time that the aud it was req uested . Aud it Name Name of the aud it b eing run. Clean Cac he Writes d ata to d isk. Result 1 c...
Page 195
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-143 change/display Network-Group 3 change/display Network-Group The Network Group sc reen is used to c hang e or d isp lay g roup s assoc iated with the loc al network. The Chang e c ommand enab les the user to ad minister the network ports and loc ations. The Disp lay c ommand allows the user to d isp lay the groups. change network group
Page 196
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-144 change/display Network-Group 3 display network group Field Descriptions Name Description Valid Entries Memb er The memb er numb er of the network g roup1 or 2 Port The network p ort loc ation assig ned to this network g roup memb erPort in the form - p ort-network c arrier b oard slot, e.g ., 1A0401 Extension The extension attac hed to the portA switch extension number with leng th...
Page 197
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-145 busyout Network-Port 3 busyout Network-Port The Busyout/Release Network Port sc reen enables the system ad ministrator to b usy out or release a network port and to display the results of the busyout or release op eration.The busyout network port port- address c ommand takes the port specified by port-address out of service. busyout network port port- address Returns the port specified...
Page 198
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-146 busyout Network-Port 3 Field Descriptions Sample Tasks To b usy-out a network p ort: 1. Type busyout network port port-address [forced ] and press (Enter). Th e port-address and the op tional keyword , forced , are described above in the Command s section. 2. Press (Canc el) to ab ort the op eration and exit the sc reen. 3. Press (Enter) to invoke the b usy-out operation. To...
Page 199
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-147 test Network-Port 3 test Network-Port The Test Networking Port Results sc reen enab les the user to test the network p ort connec tion. This screen tests the networking port spec ified by < loc> . There is a short test and a long test that resets the p ort, a test that starts the 64k-loop test, a test that starts the 56k-loop test, and a test that stop s the ong oing test. The loop...
Page 200
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-148 test Network-Port 3 Field Description (display only) Func tion Keys: Initially, p ressing (Canc el) returns the user to the c ommand line without exec uting the test. Pressing (Enter) starts the test. While the test is running , p ressing (Canc el) ab orts the test and pressing (Enter) p uts the test in the b ac kg round and returns the user to the c ommand line. The “ status...