Page 81
Maintaining Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems State Database Replicas75 State Database Replicas 3 Setting up replicas31. Verify that the /etc/opt/SUNWmd/md.tab file is correct (see “Examples of valid system files” on page 79 ). 2. Enter the metadb command: Replacing replicas3Sometimes replicas may have to be replaced. A replica can become corrupted, for example, and in that case needs to be removed and then recreated. The procedure to do that is as follows: 1....
Page 82
Maintaining Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Partitioning disks with the format command76 Partitioning disks with the format command3 To use the format command to partition a disk, do the following steps: 1. Enter:# format A menu of disks displays. You are asked to select one. 2. Enter the menu number of the disk to be partitioned. A list of commands displays, followed by the format> prompt. 3. Enter:format> partition The partition> prompt displays. 4....
Page 83
Maintaining Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Partitioning disks with the format command77 6. Enter:partition> print The partition table displays and the partition> prompt returns. Compare the display to the Partitioning table to make certain you have repartitioned the disk properly. If not, repeat step 5. 7. Enter:partition> label The system responds Ready to label disk, continue? . 8. Enter:y 9. The partition> prompt returns. 10. Enter:partition> q The...
Page 84
Maintaining Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems How to tell whether your mirrored system is standard78 How to tell whether your mirrored system is standard3 To tell whether mirroring was installed as a “standard” or “nonstandard” configuration, you can do one of two things. Either: a. Enter the command:# metastat d11 d12 b. Edit the /etc/opt/SUNWmd/md.tab file Examine the command output or the contents of the file. You are looking for the d11 and d12 metadevices...
Page 85
Maintaining Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Examples of valid system files79 Examples of valid system files3 Va l i d vfstab files3 Va li d vfstab file for a non mirrored R3V8 CMS system: ___________________________________________________________________ #device device mount FS fsck mount mount #to mount to fsck point type pass at boot options # #/dev/dsk/c1d0s2 /dev/rdsk/c1d0s2 /usr ufs 1 yes - fd - /dev/fd fd - no - /proc - /proc proc - no -...
Page 86
Maintaining Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Examples of valid system files80 Va l i d md.tab files3 Va li d md.tab file for a 3 disk non mirrored R3V8 CMS system: ____________________________________________________ #state database replicas mddb00 c0t0d0s1 mddb01 c0t1d0s0 #/cms d19 3 1 /dev/rdsk/c0t0d0s3 1 /dev/rdsk/c0t1d0s1 1 /dev/rdsk/c1t0d0s1 d21 -m d19 ____________________________________________________ Va li d md.tab file for a 4 disk mirrored R3V8 CMS...
Page 87
Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Solstice DiskSuite problems81 4 Troubleshooting4 This chapter contains procedures for troubleshooting problems you may experience while installing or maintaining systems that use disk mirroring. Solstice DiskSuite problems4 The root filesystem runs out of space during a system install 4 If you run out of space on the /(root) file system—while trying to install Solaris patches, for example—you probably installed your /cms swap...
Page 88
Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems The system fails to recognize all disk drives82 The system fails to recognize all disk drives4 If the system should fail to recognize all disk drives, do the following: 1. Reboot the system by entering the following command: The system reboots and displays the ok prompt: 2. Turn off the system unit. 3. Turn off all external devices starting with the system monitor and working toward the device farthest from the system unit. 4....
Page 89
Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems The system fails to recognize all disk drives83 7.IMPORTANT! If you had to do a reset-all command, reset autoboot? to true by entering the following command: Failure to reset autoboot? before the next reboot will cause the reboot to stop at the boot prompt instead of proceeding through the normal boot-up. 8. When you have verified that the system is recognizing all its disk drives, reboot the system with a boot -r command...
Page 90
Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Fixing “needs maintenance” messages84 Fixing “needs maintenance” messages4 On rare occasions mirrors may get severely out of sync. An extreme example is when a disk is removed from a powered system without first being detached with a metadetach command. The situation is indicated by the appearance of a Needs maintenance message in a State line of a metastat response. For example: In such situations the metareplace command...