Page 31
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems How to upgrade an Enterprise platform to disk mirroring25 Step 10: Verify disk space 2 1. Display available disk space by entering a df -k command. The system responds with a file system table. For example: The figures on the /dev/md/dsk/d21 line are critical. You will use them to determine whether Solstice DiskSuite* is administering all your disks. 2. Complete the table below by filling in (1a) and (1b) as...
Page 32
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems How to upgrade an Enterprise platform to disk mirroring26 If the stripes of d19 and d20 do not account for all the disk drives on your system, check your disk drive connections. If discrepancies persist, telephone the Lucent National Customer Care Center at 1.800.242.2121, or contact your Lucent representative or distributor. Step 11: Create an alternate boot device 2 Set up an alternate boot device by doing the...
Page 33
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems How to upgrade an Enterprise platform to disk mirroring27 3. Reboot the system with the following command: The system displays the ok prompt. 4. Create a device alias for the new boot device by entering the following command (for example): Replace with what you recorded in item 2. For the example shown, you would replace with the following: /sbus@3,0/SUNW,fas@3,8800000/sd@2,0 5. Test the alternate boot device...
Page 34
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring28 Factory installation procedures for disk mirroring2 This section describes how a mirrored system is installed on a new Sun Enterprise 3xxx computer in the factory. You may use these instructions in the field to bring an existing system up to factory specifications. Step 1: Install the hardware 2 Install hardware components as required. For details and...
Page 35
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring29 . Step 3: Install the application software 2 Install application software as instructed in the CentreVu CMS R3V8 Software Installation and Setup (585-210-941) document. That will mean installing the following packages in order: lCommon Desktop Environment (CDE) lSunLink* HSI/S drivers (if using HSI/S ports) lNTS drivers (if using NTS ports) lX.25 (if using X.25...
Page 36
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring30 Step 4: Check the disk.type file2 The olds commands, which you will be using to configure the Solstice DiskSuite software, obtain information about your disk configuration from the /olds/disk.type file. If your boot disks are not as specified in the Disks table in Step 2, check the disk.type file to verify that it names the proper boot disks for your system....
Page 37
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring31 5. Check the disks: 6. Create system files for the Solstice DiskSuite software: 7. Make sure all the disk drives on your system have been recognized. To do that, read the file /olds/md.tab.new into an editor and locate the #/cms section. It should reflect the precise number of disk drives on your system. The following example shows a total of four disk drives...
Page 38
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring32 Step 6: Run the setup scripts 2 1. Create the state database replicas by entering the following command: 2. Mirror the root file system by entering the following command: 3.Check disks with “metastat ” and wait until all disks are synched. Ignore any FSCK error messages which may be generated. 4. Reboot and log in as the root user (boot -r) : # olds -mirrored...
Page 39
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring33 5. Setup the /cms metadevices by entering the following commands: 6. Create and mount the /cms file system by entering the following commands: Step 7: Verify disk space 2 1. Display available disk space by entering a df -k command. The system responds with a file system table. For example: The figures on the /dev/md/dsk/d21 line are critical. You will use them...
Page 40
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems Factory installation procedures for disk mirroring34 2. Complete the table below by filling in (1a) and (1b) as instructed. 3. Compare the figures in (1a) and (1b). They should be approximately equal. The two will not correspond exactly, but they should be within about 10% of the /cms size figure. A major discrepancy between the disk space you should have and the space recognized by the software usually indicates a...