AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-35 getevent 
12
getevent
Get event d ata 
Syntax 
getevent
   [-d
 mmddyy [-t
 hhmm]] [-c
 code] [-f
 searc h string] [-s
 session]
     [-R
 
reporting-resource-type] [-T
 resource-typ e [-L loc ation]]
     [-a
 
y/n] [-e
 y/n] [-E
 y/n] [-n
 nnnnn] [-r release] [-v
] [-w
] [-V
]
     [
> ofile]
Description 
This c ommand  retrieves all p ag es of the following  sc reens for...

Page 252

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-36 getevent 
12
y/n Retrieves or does not retrieve alarm information. Alarm information 
inc lud es the following  event typ es: 
ALARM The event rep resenting the ac tivation of an alarm.
RES_MNT Alarm resolved  b y maintenanc e ac tivity.
RES_RST Alarm resolved  b y restart.
RES_REM Alarm resolved  b y removal of alarmed  resourc e.
-E
Error information flag ; must b e followed...

Page 253

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-37 getevent 
12
NOTE:
The g etevent c ommand  req uires the craft log in for the DEFINITY AUDIX 
Sy st e m .  
Errors 
If no events exist that fit the spec ified searc h, no output is written. If you use this 
c ommand  with an I
NTUITY AU D I X o r  R1  AU D I X Sy st e m ,  a n  e r ro r m e s s a g e  
ap p ears on the sc reen. -L
Loc ation flag ; must b e followed  with 
loc...

Page 254

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-38 getevent 
12
Output Format
Outp ut format for the getevent
 c ommand  is formatted  as follows, with one rec ord  
for eac h event.
Example 
The following  c ommand  retrieves the DEFINITY AUDIX Display Events d ata from 
12:25 p .m. on Oc tob er 14, 1994, to the hour and  minute the c ommand  was 
entered , writes a summary of the transfer statistic s to the sc reen, and...

Page 255

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-39 getfeat 
12
getfeat
Get traffic  measurement d ata 
Syntax 
getfeat
   -f day
 [-d
 mmddyy] [-n
 nn] [-r 
release]  [-v
] [-w
] [-V
] [> ofile]
or
getfeat
   -f hour
 [-d
 mmddyy] [-t
 hh]  [-n
 nn]  [-r
 release]  [-v
] [-w
] [-V
] [> ofile]
Description 
This c ommand  retrieves d ata for the d ate sp ec ified  for the following  sc reens: 
nINTUITY AUDIX List Measurements...

Page 256

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-40 getfeat 
12
hh Retrieves d ata for the hour of the day that you have sp ec ified  
alread y b y 
mmddyy. For examp le, if you enter 15
 without 
subsequently entering the n
 op tion, the d ata from 3:00 p.m. to 4:00 
p.m. will be retrieved. 
-n
Numb er of rec ord s flag ; must b e followed  b y 
nn. If you d on’t 
inc lud e this op tion, only one rec ord  (hour or d ay) will b...

Page 257

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-41 getfeat 
12
Output Format
Outp ut format for the getfeat
 c ommand  with the -f hour
 op tion is formatted  as 
follows, with one rec ord  p er hour.
FIELD       VOICE MAIL VERSIONS
Seq. 
No. Field Name TypeMax.
WidthR1
AUDIX
System 
DEFINITY
AUDIX
System
INTUITY
AUDIX 
System
1 starting date D 8 r1v3+ D-r1.0+ I-r2.0+
2 starting  hour N 2 r1v3+ D-r1.0+ I-r2.0+
3 end ing  time...

Page 258

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-42 getfeat 
12
Outp ut format for the getfeat
 c ommand  with the -f day 
option is formatted  as 
follows, with one rec ord  p er d ay.
37 successful client logins N 8I-r5.0+
38 failed  c lient log ins N 8
I-r5.0+
39 c lient voic e mail session usag e N 8
I-r5.0+
40 c omp leted  network c all answer c alls N 8
I-r5.0+
41 c all answer voic e c omponents external N 8
I-r5.0+
42 c...

Page 259

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-43 getfeat 
12
10 VM total messag es, sent N 10 r1v3+ D-r1.0+ I-r2.0+
11 VM total messag es, d eleted N 5 r1v3+ D-r1.0+ I-r2.0+
12 VM total messag es, c urrent N 19 r1v3+ D-r1.0+ I-r2.0+
13 VM averag e storage time N 8 r1v3+ D-r1.0+ I-r2.0+
14 VM averag e c onnec t time N 6 r1v3+ D-r1.0+ I-r2.0+
15 CA c omp leted c alls, external N 8 r1v3+ D-r1.0+ I-r2.0+
16 CA c omp leted c...

Page 260

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Command Line Database Retrieval Commands 
12-44 getfeat 
12
NOTE:
Field  11, VM total messag es d eleted, and  Field  21, CA messag es d eleted, 
are rep orted as numeric  zero for AUDIX R1V5 throug h R1V8 and all 
releases of DEFINITY AUDIX
Errors 
If either the d ate or time is invalid  when c ommunic ating with an R1 AUDIX
System, the retrieval is ab orted  and  no rec ord s are written. 