LG M3201c Users Guide
Here you can view all the pages of manual LG M3201c Users Guide. The LG manuals for Television are available online for free. You can easily download all the documents as PDF.
Page 51
Controlling the Multiple ProductRS-232C A9 11. Sharpness(Command : k) (Video only)To adjust the screen Sharpness. You can also adjust the sharpness in the Picture menu. Transmission [k][k][ ][Set ID][ ][Data][Cr] Data Min : 00H ~ Max : 64H (Hexadecimal code) • Refer to ‘Real data mapping’ page A7. Acknowledgement [k][ ][Set ID][ ][OK][Data][x] Data Min : 00H ~ Max : 64H 12. OSD Select(Command : l) To control OSD on/off to the set. Transmission [k][l][ ][Set ID][ ][Data][Cr] Data 0 : OSD Off 1...
Page 52
Controlling the Multiple ProductRS-232C A10 Transmission / Receiving Protocol 14 Balance(Command : t)To adjust the sound balance. Transmission [k][t][ ][Set ID][ ][Data][Cr] Data Min : 00H ~ Max : 64H (Hexadecimal code) • Refer to ‘Real data mapping’ page A7. Acknowledgement [t][ ][Set ID][ ][OK][Data][x] Data Min : 00H ~ Max : 64H * Balance : L50 ~ R50 15. Color Temperature (Command : u) To adjust the screen color temperature. Transmission [k][u][ ][Set ID][ ][Data][Cr] Data 0 : Normal 1 : Cool 2 :...
Page 53
Controlling the Multiple ProductRS-232C A11 Transmission / Receiving Protocol 16. Abnomal state (Command : z)Abnormal State : Used to Read the power off status when Stand-by mode. Transmission [k][z][ ][Set ID][ ][Data][Cr] Data FF : Read 0 : Normal (Power on and signal exist) 1: No signal (Power on) 2 : Turn the monitor off by remote control 3 : Turn the monitor off by sleep time function 4 : Turn the monitor off by RS-232C function 6 : AC down 8 : Turn the monitor off by off time function 9 : Turn...
Page 54
Controlling the Multiple ProductRS-232C A12 18. Auto Configure(Command: j u)To adjust picture position and minimize image shaking automatically. it works only in RGB(PC) mode. Transmission [j][u][ ][Set ID][ ][Data][Cr] Data 1 : To set Acknowledgement [u][ ][Set ID][ ][OK][Data][x] 19. Key(Command : m c) To send IR remote key code. Transmission [m][c][ ][Set ID][ ][Data][Cr] Data Key code : Refer to page A18. Acknowledgement [c][ ][Set ID][ ][OK][Data][x] Transmission / Receiving Protocol
Page 55
Controlling the Multiple ProductRS-232C A13 20. Tile Mode(Command : d d)Change a Tile Mode. Transmission [d][d][][Set ID][][Data][x] * The data can not be set to 0X or X0 except 00. Acknowledgement [d][][00][][OK/NG][Data][x] Transmission / Receiving Protocol DataDescription 00Tile mode is off. 121 x 2 mode(column x row) 131 x 3 mode 141 x 4 mode ...... 444 x 4 mode
Page 56
Controlling the Multiple ProductRS-232C A14 21. Tile H Size(Command : d g)To set the Horizontal size. Transmission [d][g][][Set ID][][Data][x] Data Min : 00H ~ Max : 64H Acknowledgement [g][][Set ID][][OK/NG][Data][x] 22. Tile V Size(Command : d h) To set the Vertical size. Transmission [d][h][][Set ID][][Data][x] Data Min : 00H ~ Max : 64H Acknowledgement [h][][Set ID][][OK/NG][Data][x] Transmission / Receiving Protocol
Page 57
Controlling the Multiple ProductRS-232C A15 23. Tile ID Set(Command : d i)To assign the Tile ID for Tiling function . Transmission [d][i][][Set ID][][Data][x] Data Min : 00H ~ Max : 10H (Hexadecimal code) Acknowledgement [i][][Set ID][][OK/NG][Data][x] 24. Elapsed time return(Command : d l) To read the elapsed time. Transmission [d][l][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [l][][Set ID][][OK/NG][Data][x] * The data means used hours. (Hexadecimal code) Transmission /...
Page 58
Controlling the Multiple ProductRS-232C A16 25. Temperature value (Command : d n) To read the inside temperature value. Transmission [d][n][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [n][][Set ID][][OK/NG][Data][x] * The data is 1 byte long in Hexadecimal. 26. Lamp fault Check(Command : d p) To check lamp fault. Transmission [d][p][][Set ID][][Data][x] * The data is always FF(in Hex). Acknowledgement [p][][Set ID][][OK/NG][Data][x] Data 0 : Lamp Fault 1: Lamp OK...
Page 59
IR CodesRS-232C A17 How to connect Remote Control IR Code Connect your wired remote control to Remote Control port on the Product.\ Output waveform single pulse, modulated with 37.917KHz signal at 455KHz Carrier frequency FCAR = 1/Tc = fosc/12 Duty ratio = T1/Tc = 1/3 Configuration of frame • 1st frameT1 Lead code Low custom code High custom code Data code Data code C0 C1 C2 C3 C4 C5 C6 C7 C0 C1 C2 C3 C4 C5 C6 C7 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 Tc Tf • Repeat frame Repeat code Lead...
Page 60
RS-232C A18 00 01 02 03 08 C4 C5 09 98 0B 0E 43 5B 6E 44 10 11 12 13 14 15 16 17 18 19 5A BF D4 D5 D7 C6 79 76 77 AF 99 VOL( ) VOL( ) POWER ON/OFF POWER ON POWER OFF MUTE AV INPUT SLEEP MENU EXIT PSM SET Number Key 0 Number Key 1 Number Key 2 Number Key 3 Number Key 4 Number Key 5 Number Key 6 Number Key 7 Number Key 8 Number Key 9 AV COMPONENT1 COMPONENT2 RGB PC RGB DTV HDMI/DVI ARC ARC (4:3) ARC (16:9) ARC (ZOOM) AUTO CONFIC R/C Button R/C Button R/C Button R/C Button PR/C Button (Power...